JOSEP RUBIO-PALAU

Dr. JOSEP RUBIO-PALAU

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2023 in Gels
Verified
Journal Article
Open access
PDF file
AVArnau Valls-Esteve
Arnau Valls-Esteve
ATAitor Tejo
Aitor Tejo
PLPamela Lustig-Gainza
Pamela Lustig-Gainza
Irene Buj-CorralIrene Buj-Corral
Irene Buj-Corral
Felip FenollosaFelip Fenollosa
Felip Fenollosa
LKLucas Krauel
Lucas Krauel
Background: Pre-surgical simulation-based training with three-dimensional (3D) models has been intensively developed in complex surgeries in recent years. This is also the case in liver surgery, although with fewer reported examples. The simulation-based training with 3D models represents an alternative to current surgical simulation methods based on animal or ex vivo models or virtual reality (VR), showing reported advantages, which makes the development of realistic 3D-printed models an option. This work presents an innovative, low-cost approach for producing patient-specific 3D anatomical models for hands-on simulation and training. Methods: The article reports three paediatric cases presenting complex liver tumours that were transferred to a major paediatric referral centre for treatment: hepatoblastoma, hepatic hamartoma and biliary tract rhabdomyosarcoma. The complete process of the additively manufactured liver tumour simulators is described, and the different steps for the correct development of each case are explained: (1) medical image acquisition; (2) segmentation; (3) 3D printing; (4) quality control/validation; and (5) cost. A digital workflow for liver cancer surgical planning is proposed. Results: Three hepatic surgeries were planned, with 3D simulators built using 3D printing and silicone moulding techniques. The 3D physical models showed highly accurate replications of the actual condition. Additionally, they proved to be more cost-effective in comparison with other models. Conclusions: It is demonstrated that it is possible to manufacture accurate and cost-effective 3D-printed soft surgical planning simulators for treating liver cancer. The 3D models allowed for proper pre-surgical planning and simulation training in the three cases reported, making it a valuable aid for surgeons.

27 December 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
AVArnau Valls-Esteve
Arnau Valls-Esteve
ATAitor Tejo
Aitor Tejo
NANúria Adell-Gómez
Núria Adell-Gómez
PLPamela Lustig
Pamela Lustig
Felip FenollosaFelip Fenollosa
Felip Fenollosa
LKLucas Krauel
Lucas Krauel
The printing and manufacturing of anatomical 3D models has gained popularity in complex surgical cases for surgical planning, simulation and training, the evaluation of anatomical relations, medical device testing and patient–professional communication. 3D models provide the haptic feedback that Virtual or Augmented Reality (VR/AR) cannot provide. However, there are many technologies and strategies for the production of 3D models. Therefore, the aim of the present study is to show and compare eight different strategies for the manufacture of surgical planning and training prototypes. The eight strategies for creating complex abdominal oncological anatomical models, based on eight common pediatric oncological cases, were developed using four common technologies (stereolithography (SLA), selectie laser sinterning (SLS), fused filament fabrication (FFF) and material jetting (MJ)) along with indirect and hybrid 3D printing methods. Nine materials were selected for their properties, with the final models assessed for application suitability, production time, viscoelastic mechanical properties (shore hardness and elastic modulus) and cost. The manufacturing and post-processing of each strategy is assessed, with times ranging from 12 h (FFF) to 61 h (hybridization of FFF and SLS), as labor times differ significantly. Cost per model variation is also significant, ranging from EUR 80 (FFF) to EUR 600 (MJ). The main limitation is the mimicry of physiological properties. Viscoelastic properties and the combination of materials, colors and textures are also substantially different according to the strategy and the intended use. It was concluded that MJ is the best overall option, although its use in hospitals is limited due to its cost. Consequently, indirect 3D printing could be a solid and cheaper alternative.

3 June 2024 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
NANúria Adell-Gómez
Núria Adell-Gómez
AVAdaia Valls-Ontañón
Adaia Valls-Ontañón
AMAlbert Malet-Contreras
Albert Malet-Contreras
AGAndrés García-Piñeiro
Andrés García-Piñeiro
MGMarta Gómez-Chiari
Marta Gómez-Chiari
JRJOSEP RUBIO-PALAU
JOSEP RUBIO-PALAU

7 January 2026 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Open access
NANúria Adell-Gómez
Núria Adell-Gómez
AVArnau Valls-Esteve
Arnau Valls-Esteve
AMAlbert Malet-Contreras
Albert Malet-Contreras
JRJordi Raurich-Leandro
Jordi Raurich-Leandro
RRRaimon Ripoll-Palmés
Raimon Ripoll-Palmés
JRJOSEP RUBIO-PALAU
JOSEP RUBIO-PALAU
Orthognathic surgery is widely used to correct dentofacial deformities. Recent advancements in virtual surgical planning have enhanced the precision of these procedures. However, ensuring the surgical outcome reflects the virtual plan remains a challenge. This study aims to compare surgical accuracy and cost-efficiency between standard miniplates and patient-specific implants, using intraoperative computed tomography and 3D superposition. A total of 90 patients were included: 75 retrospective controls treated with standard implants and 15 prospective patients treated with patient-specific implants. Surgeries included Le Fort I, BSSO, and genioplasty. Intraoperative computed tomography scans were acquired and superposed with virtual plans to assess 3D accuracy. Statistical comparisons were made using the Mann-Whitney U test. The patient-specific implant group demonstrated significantly improved surgical accuracy in maxillary midline, mandibular midline, maxillary dental plane, and pogonion (p < 0.05). One patient with patient-specific implant required intraoperative replacement of mandibular plates due to condylar repositioning. Cost analysis revealed higher costs for PSI cases compared to standard, with no significant difference in surgical time. While patient-specific implants offer benefits in standardization and intraoperative precision, their higher cost and reduced adaptability in the mandible limit their application. Future studies should explore hybrid approaches and broader cost-efficiency analysis.

1 October 2021 in Journal Français d'Ophtalmologie
Verified
Journal Article
Closed access
MQM.J. Quiroz-Quiroga
M.J. Quiroz-Quiroga
HVH. González Valdivia
H. González Valdivia
APAna Palazon-Cabanes
Ana Palazon-Cabanes
JRJOSEP RUBIO-PALAU
JOSEP RUBIO-PALAU
JBJ. Prat Bartomeu
J. Prat Bartomeu

11 June 2024 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
AVAdaia Valls-Ontañón
Adaia Valls-Ontañón
AMA. Malet-Contreras
A. Malet-Contreras
FPF. Peralta-Amores
F. Peralta-Amores
NANúria Adell-Gómez
Núria Adell-Gómez
CFC. Flores
C. Flores
JRJOSEP RUBIO-PALAU
JOSEP RUBIO-PALAU