In the case of adjustable drives systems with an induction motor (IM), a harmonic regime is manifested, whose knowledge and analysis are always necessary. However, most studies are focused on specific drive systems, the results of these works being valid only for drive systems of the same type. The objective of the present paper was to determine the harmonics consequences not only on the technical characteristics of the IM but also on the power supply as well as on the mechanical drive system. Thus, by initiating a methodology for estimating the consequences of each voltage harmonic separately, the aim was to substantiate a generally applicable method, which allows the evaluation, for any application, of the overall effects of the harmonics. The main feature of the method used in this paper was the consideration of the presence of voltage harmonics in the stator voltage of the IM, of certain frequencies and with certain levels, and the determination of all the electrical and mechanical consequences on the model of the drive system. It has been found that the harmonics of the IM affects the power quality (PQ) of the power supply, having significant influences also on the mechanical part of the drive system.
The design methods of earthing from standards recommend the choice of electrode lengths and propose that the distances between electrodes to be 1–3 times larger than their length. The number of electrodes is determined from the condition of achieving the design earth resistance, while the design ends with the choice of one of the variants. This paper presents the methodology for calculating the earthing system with cylindrical, vertical electrodes arranged in a line. The main variables are the length and the number of earth electrodes, as well as the distance between adjacent ones. Firstly, a set of technologically advantageous values for the earth electrode length is established (e.g., 10 values). For each value of the electrode length and different numbers of electrodes (e.g., 11 values), the distance between adjacent electrodes is determined (e.g., for 110 cases), which leads to the design value resistance. Finally, optimal solutions are identified based on the five optimal applied criteria. The proposed optimal criteria for earthing design are the footprint area, the total earthing volume, the total dispersion surface, the total metal mass, and the investment costs. Comparing the optimal solutions with other technically possible solutions clearly highlights substantial savings concerning space, material, and cost.
Short-term electricity load forecasting has attracted considerable attention as a result of the crucial role that it plays in power systems and electricity markets. This paper presents a novel hybrid forecasting method that combines an autoregressive model with Gaussian process regression. Mixed-user, hourly, historical data are used to train, validate, and evaluate the model. The empirical wavelet transform was used to preprocess the data. Among the perturbing factors, the most influential predictors that were recorded were the weather factors and day type. The developed methodology is upgraded using a novel closed-loop algorithm that uses the forecasting values and influential factors to predict the residuals. Most performance indicators that are computed indicate that forecasting the residuals actually improves the method’s precision, decreasing the mean absolute percentage error from 5.04% to 4.28%. Measured data are used to validate the effectiveness of the presented approach, making it a suitable tool for use in load forecasting by utility companies.