Background: There is limited data about transcatheter aortic valve replacement (TAVR) from China, where there are significant differences in the patient population both clinically and anatomically. This study sought to assess the clinical profile and outcomes of TAVR using the Venus MedTech A-valve in China. Methods: From 2012 to 2015, 101 patients with Society of Thoracic Surgeon (STS) scores ≥4% or at prohibitive surgical risk were enrolled from four academic cardiovascular centers in China. Among 97 patients with native aortic stenosis (AS), there were 44 (45.4%) bicuspid aortic valve (BAV) and 53 (54.6%) tricuspid aortic valve (TAV) replacements. Results: Patients were 75.4 ± 6.4 years old, and the median STS score was 5.5% (inter-quartile range, IQR, 3.8%–9.2%). The device success rate was 84.2% (85/101) and the 2-year cumulative survival rates was 90.1% overall. There was no significant difference between the BAV and TAV arms for device success (79.5% vs. 86.8%; p = 0.06), annulus rupture (0%), and other procedural complications. Periprocedural paravalvular regurgitation ≥ moderate (11.4% in BAV vs. 6.0% in TAV, p = 0.56), 30-day mean gradients (10.0 [IQR, 7.0–13.0] mmHg in BAV vs. 10.0 [IQR, 6.0–14.0] mmHg in TAV; p = 0.85), and 30-day mortality (6.8% vs. 3.8%; p = 0.50) were also similar in both groups. Significant cardiac function improvements were observed in both groups at 30-day and 180-day follow-up. At 2 years, the cumulative survival rates (90.9% in BAV vs. 88.6% in TAV, p = 0.72) showed no significant differences between the two groups. Conclusions: The AS population in China presenting for TAVR has a high prevalence of BAV. The treatments with a Chinese TAVR device are favorable and similar to those in TAV.
Background: Stress hyperglycemia ratio (SHR) has recently been recognized as a novel biomarker that accurately reflects acute hyperglycemia status and is associated with poor prognosis of heart failure. We evaluated the relationship between SHR and clinical outcomes in patients with severe aortic stenosis receiving transcatheter aortic valve replacement (TAVR). Methods: There were 582 patients with severe native aortic stenosis who underwent TAVR consecutively enrolled in the study. The formula used to determine SHR was as follows: admission blood glucose (mmol/L)/(1.59×HbA1c[%]–2.59). The primary endpoint was defined as all-cause mortality, while secondary endpoints included a composite of cardiovascular mortality or readmission for heart failure, and major adverse cardiovascular events (MACE) including cardiovascular mortality, non-fatal myocardial infarction, and non-fatal stroke. Multivariable Cox regression and restricted cubic spline analysis were employed to assess the relationship between SHR and endpoints, with hazard ratios (HRs) and 95% confidence intervals (CIs). Results: During a median follow-up of 3.9 years, a total of 130 cases (22.3%) of all-cause mortality were recorded. Results from the restricted cubic spline analysis indicated a linear association between SHR and all endpoints (p for non-linearity > 0.05), even after adjustment for other confounding factors. Per 0.1 unit increase in SHR was associated with a 12% (adjusted HR: 1.12, 95% CI: 1.04–1.21) higher incidence of the primary endpoint, a 12% (adjusted HR: 1.12, 95% CI: 1.02–1.22) higher incidence of cardiovascular mortality or readmission for heart failure, and a 12% (adjusted HR: 1.12, 95% CI: 1.01–1.23) higher incidence of MACE. Subgroup analysis revealed that SHR had a significant interaction with diabetes mellitus with regard to the risk of all-cause mortality (p for interaction: 0.042). Kaplan-Meier survival analysis showed that there were significant differences in the incidence of all endpoints between the two groups with 0.944 as the optimal binary cutoff point of SHR (all log-rank test: p < 0.05). Conclusions: Our study indicates linear relationships of SHR with the risk of all-cause mortality, cardiovascular mortality or readmission for heart failure, and MACE in patients with severe aortic stenosis receiving TAVR after a median follow-up of 3.9 years. Patients with an SHR exceeding 0.944 had a poorer prognosis compared to those with lower SHR values.
17 January 2024 in Reviews in Cardiovascular Medicine
The integration of artificial intelligence (AI) into clinical management of aortic stenosis (AS) has redefined our approach to the assessment and management of this heterogenous valvular heart disease (VHD). While the large-scale early detection of valvular conditions is limited by socioeconomic constraints, AI offers a cost-effective alternative solution for screening by utilizing conventional tools, including electrocardiograms and community-level auscultations, thereby facilitating early detection, prevention, and treatment of AS. Furthermore, AI sheds light on the varied nature of AS, once considered a uniform condition, allowing for more nuanced, data-driven risk assessments and treatment plans. This presents an opportunity to re-evaluate the complexity of AS and to refine treatment using data-driven risk stratification beyond traditional guidelines. AI can be used to support treatment decisions including device selection, procedural techniques, and follow-up surveillance of transcatheter aortic valve replacement (TAVR) in a reproducible manner. While recognizing notable AI achievements, it is important to remember that AI applications in AS still require collaboration with human expertise due to potential limitations such as its susceptibility to bias, and the critical nature of healthcare. This synergy underpins our optimistic view of AI’s promising role in the AS clinical pathway.
Background: The mechanism for hypoattenuating leaflet thickening (HALT) after transcatheter aortic valve replacement is still not well elucidated, and the role of Lp(a) (lipoprotein[a]) and hs‐CRP (high‐sensitivity C‐reactive protein) has rarely been studied. This study sought to test the hypothesis that the risk of HALT is associated with an elevated level of Lp(a) or hs‐CRP. Methods and Results: A total of 307 consecutive individuals who underwent a transcatheter aortic valve replacement procedure were included. All patients received their first postoperative computed tomography scans within 12 months, and raw data were analyzed on 3mensio software. HALT was defined as visually identified increased leaflet thickness with typical meniscal appearance and at least 2 different multiplanar reformation projections. Associations of Lp(a) or hs‐CRP with the risk of HALT were evaluated using multivariable logistic regression analysis. The incidence of HALT within 12 months after transcatheter aortic valve replacement in this study was 36.2%, and the risk of HALT was associated with higher baseline Lp(a) (the multivariable adjusted odds ratio [OR] for every 10 mg/dL change was 1.18 [95% CI, 1.09–1.29]) and hs‐CRP level (the multivariable adjusted OR for every 1 mg/L change was 1.08 [95% CI, 1.00–1.27]). Compared with individuals out of the top 25th percentile for both Lp(a) and hs‐CRP, the multivariable adjusted OR for HALT was 4.74 (95% CI, 1.65–14.37) for the top 25th percentile. This result remained consistent after excluding patients receiving anticoagulant therapy. Conclusions: The top 25th percentile of Lp(a) level (≥40 mg/dL) combined with the top 25th percentile of hs‐CRP level (≥3.5 mg/L) conferred a 4.74‐fold risk of HALT.
28 May 2024 in International Journal of Cardiology