A fast-growing area of research is the development of low-cost sensors for measuring air pollutants. The affordability and size of low-cost particle sensors makes them an attractive option for use in experiments requiring a number of instruments such as high-density spatial mapping. However, for these low-cost sensors to be useful for these types of studies their accuracy and precision need to be quantified. We evaluated the Alphasense OPC-N2, a promising low-cost miniature optical particle counter, for monitoring ambient airborne particles at typical urban background sites in the UK. The precision of the OPC-N2 was assessed by co-locating 14 instruments at a site to investigate the variation in measured concentrations. Comparison to two different reference optical particle counters as well as a TEOM-FDMS enabled the accuracy of the OPC-N2 to be evaluated. Comparison of the OPC-N2 to the reference optical instruments shows some limitations for measuring mass concentrations of PM1, PM2.5 and PM10. The OPC-N2 demonstrated a significant positive artefact in measured particle mass during times of high ambient RH (> 85 %) and a calibration factor was developed based upon κ-Köhler theory, using average bulk particle aerosol hygroscopicity. Application of this RH correction factor resulted in the OPC-N2 measurements being within 33 % of the TEOM-FDMS, comparable to the agreement between a reference optical particle counter and the TEOM-FDMS (20 %). Inter-unit precision for the 14 OPC-N2 sensors of 22 ± 13 % for PM10 mass concentrations was observed. Overall, the OPC-N2 was found to accurately measure ambient airborne particle mass concentration provided they are (i) correctly calibrated and (ii) corrected for ambient RH. The level of precision demonstrated between multiple OPC-N2s suggests that they would be suitable devices for applications where the spatial variability in particle concentration was to be determined.
The importance of organic aerosol particles in the environment has been long established, influencing cloud formation and lifetime, absorbing and scattering sunlight, affecting atmospheric composition and impacting on human health. Conventionally, ambient organic particles were considered to exist as liquids. Recent observations in field measurements and studies in the laboratory suggest that they may instead exist as highly viscous semi-solids or amorphous glassy solids under certain conditions, with important implications for atmospheric chemistry, climate and air quality. This review explores our understanding of aerosol particle phase, particularly as identified by measurements of the viscosity of organic particles, and the atmospheric implications of phase state.
We report quantitative, real-time, online observations of microscopic viscosity changes in aerosol particles of atmospherically relevant composition, using fluorescence lifetime imaging (FLIM) of viscosity.
This paper assesses the effect of short-term exposure to particulate matter (PM) air pollution on human cognitive performance via a double cross over experimental design. Two distinct experiments were performed, both of which exposed subjects to low and high concentrations of PM. Firstly, subjects completed a series of cognitive tests after being exposed to low ambient indoor PM concentrations and elevated PM concentrations generated via candle burning, which is a well-known source of PM. Secondly, a different cohort underwent cognitive tests after being exposed to low ambient indoor PM concentrations and elevated ambient outdoor PM concentrations via commuting on or next to roads. Three tests were used to assess cognitive performance: Mini-Mental State Examination (MMSE), the Stroop Color and Word test, and Ruff 2 & 7 test. The results from the MMSE test showed a statistically robust decline in cognitive function after exposure to both the candle burning and outdoor commuting compared to ambient indoor conditions. The similarity in the results between the two experiments suggests that PM exposure is the cause of the short-term cognitive decline observed in both. The outdoor commuting experiment also showed a statistically significant short-term cognitive decline in automatic detection speed from the Ruff 2 and 7 selective attention test. The other cognitive tests, for both the candle and commuting experiments, showed no statistically significant difference between the high and low PM exposure conditions. The findings from this study are potentially far reaching; they suggest that elevated PM pollution levels significantly affect short term cognition. This implies average human cognitive ability will vary from city to city and country to country as a function of PM air pollution exposure.