Simultaneous pancreas–kidney transplantation (SPKT) can improve long-term patient survival and restore endogenous insulin secretion in recipients with type 1 diabetes (T1D). There are currently few data on glucose fluctuations assessed by continuous glucose monitoring (CGM) after SPKT. Aim: to evaluate CGM-derived time in range (TIR) and glucose variability (GV) in patients with T1D and functioning pancreatic grafts after SPKT. Fifty-four CGM recordings from 43 patients, 15 men and 28 women, aged 34 (31; 39) years were analyzed. Time since SKPT was up to 1 year (group 1, n = 13), from 1 to 5 years (group 2, n = 15), and from 5 to 12 years (group 3, n = 26). TIR (3.9–10 mmol/L), Time Above Range (TAR), Time Below Range (TBR), and GV parameters were estimated. There were no differences in mean glucose (5.5 [5.1; 6.2], 5.9 [5.4; 6.2], and 5.9 [5.6; 6.7] mmol/L), TIR (97.6 [92.8–99.1], 97.2 [93.2; 99.1], and 97.5 [93.4; 99]%); TAR (0, 1.8 [1.3; 3.7], and 2.5 [2; 5]%), TBR (5 [3.3; 12.7], 4.1 [2.2; 10.1], and 3.5 [1.3; 6.5]%) and GV parameters between three groups (all p > 0.05). Thus, recipients with functioning pancreatic grafts demonstrate remarkably high TIR and low GV after SPKT.
15 April 2021 in Clinical nutrition and metabolism
To diagnose and dynamically monitor patients with diseases accompanied by changes in body composition, data from a number of hardware analytical methods are required. Non-invasive, without radiation and chemical loads, fast and patientfriendly bioimpedance analysis of body composition comprehensively solves the problem of obtaining quantitative estimates of all components of body composition at the same time. This article discusses the terminology features of bioimpedance analysis of body composition and the most common mistakes in the use of terms. In the Russian-speaking medical environment, you can often find the use of a number of inaccurate terms related to bioimpedance analysis of the human body composition. At the same time, the terminology of bioimpedance analysis of human body composition in English-language publications has long been established. The article presents the Russian and English terms of bioimpedance analysis of the human body composition with corresponding abbreviations, as well as the hierarchy of the terms body composition components, body composition parameters, parameters of bioimpedance analysis of body composition and bioimpedance parameters. The most developed areas of application of bioimpedance analysis in medical practice are discussed: assessment of nutrition and dynamic observations of changes in body composition, assessment of the body mineral mass, assessment of the body hydration parameters, assessment of blood supply to tissues and organs, including in the monitoring mode, assessment of the asymmetry of paired organs and limbs, assessment of pre-start readiness, physical development and the level of fitness of the athletes muscular system.
1 January 2021 in Journal of Electrical Bioimpedance
The BIA primary result sheets as a rule contain one-dimensional graphical scales with a selected area of normal values. In 1994, Piccoli et al. proposed BIVA, an alternative form of BIA data presentation, where two bioimpedance parameters are considered simultaneously as tolerance ellipses: resistance and reactance normalized to height. The purpose of this study is to develop an approach to data analysis in body composition bioimpedance research in two-dimensional representations. The data of 1.124.668 patients aged 5 to 85 years who underwent a bioimpedance study in Russian Health Centers from 2009 to 2015 were used. Statistical programming in the R Studio environment was carried out to estimate two-dimensional distribution densities of pairs of body composition parameters for each year of life. The non-Gaussian distribution is found in most parameters of bioimpedance analysis of body composition for most ages (Lilliefors test, p-value << 0.0001). The slices of the actual two-dimensional distribution pairs of body composition parameters had an irregular shape. The authors of the article propose using the actually observed distribution for populations where numerous bioimpedance studies have already been carried out. Such technology can be called two-dimensional bioimpedance analysis of human body composition (2DBIA). The 2DBIA approach is clearer for practitioners and their patients due to the use of body composition parameters in addition to electrical impedance parameters.
BACKGROUND: Pathological low-energy (LE) vertebral compression fractures (VFs) are common complications of osteoporosis and predictors of subsequent LE fractures. In 84% of cases, VFs are not reported on chest CT (CCT), which calls for the development of an artificial intelligence-based (AI) assistant that would help radiology specialists to improve the diagnosis of osteoporosis complications and prevent new LE fractures.AIMS: To develop an AI model for automated diagnosis of compression fractures of the thoracic spine based on chest CT images.MATERIALS AND METHODS: Between September 2019 and May 2020 the authors performed a retrospective sampling study of ССТ images. The 160 of results were selected and anonymized. The data was labeled by seven readers. Using the morphometric analysis, the investigators received the following metric data: ventral, medial and dorsal dimensions. This was followed by a semiquantitative assessment of VFs degree. The data was used to develop the Comprise-G AI mode based on CNN, which subsequently measured the size of the vertebral bodies and then calculates the compression degree. The model was evaluated with the ROC curve analysis and by calculating sensitivity and specificity values.RESULTS: Formed data consist of 160 patients (a training group - 100 patients; a test group - 60 patients). The total of 2,066 vertebrae was annotated. When detecting Grade 2 and 3 maximum VFs in patients the Comprise-G model demonstrated sensitivity - 90,7%, specificity - 90,7%, AUC ROC - 0.974 on the 5-FOLD cross-validation data of the training dataset; on the test data - sensitivity - 83,2%, specificity - 90,0%, AUC ROC - 0.956; in vertebrae demonstrated sensitivity - 91,5%, specificity - 95,2%, AUC ROC - 0.981 on the cross-validation data; for the test data sensitivity - 79,3%, specificity - 98,7%, AUC ROC - 0.978.CONCLUSIONS: The Comprise-G model demonstrated high diagnostic capabilities in detecting the VFs on CCT images and can be recommended for further validation.
The practical application of the bioimpedance analysis of human body composition (BIA) technology began four decades ago. The first two-dimensional representation of the dependence of one bioimpedance parameter on another was proposed in 1994 in the work of Piccoli et al. This representation is referred to as bioimpedance vector analysis (BIVA). The position of the point in BIVA coordinates has an unambiguous relationship with values of the phase angle (PA), as BIVA coordinates can be used for calculating PA. In this case, the two-dimensional BIVA graph can be supplemented with values of the phase angle ranges, thus forming a pseudo-three-dimensional representation. Continuing with the BIVA logic, you can use other pairs of BIA parameters to build two-dimensional representations (and in some cases, pseudo-three-dimensional), including body composition parameters. This technology can be referred to as the two-dimensional bioimpedance analysis of the human body composition (2D BIA or BIVA HBC - bioimpedance vector analysis of human body composition). The informativeness of BIVA reports and BIVA HBC reports, in the case when the values deposited along the axes are clinically related, will increase. Nevertheless, the practice of using various BIA techniques indicates that from 6 to 10 parameters are used to obtain a complete picture of the processes of changing body composition. In terms of BIVA HBC, it is 3–5 visual representations, and with the partial use of BIVA HBC+ technology (with the introduction of the third parameter), in the monitoring window, you can limit yourself to tracking 2–4 forms of visual representation of body composition parameters.
Objective : The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for monitoring of the body regions′ blood-filling redistribution and to analyze the dynamics of blood-filling redistribution during rotation in three SRC rotation modes. Approach : Nine healthy male volunteers have been observed under three SRC rotation modes with a maximum acceleration of 2.05 standard Earth gravity ( g ), 2.47 g , 2.98 g along the body vertical axis towards the legs with a rotation radius of 235 cm. The 5 kHz electrical resistance was evaluated using a bioimpedance analyzer in a polysegmental mode. Main results : Twenty-five correct records were made, of which four records were incomplete since the tests had to be stopped because the subjects were not feeling well. There was a blood-filling decrease in the head region; resistance increased to +15.4% ± 4.1% in the first SRC rotation mode. The electrical resistance of the leg regions decreased to −16.5% ± 2.3%. Slowdown of the SRC led to the reverse changes in resistance. The blood redistribution in the head and leg regions was independent of the mode of SRC rotation during the first 30 min, and varied on average by +10% and −15% respectively. Significance : Bioimpedance monitoring is promising for detection and prediction of blood circulation changes during rotation on the SRC.