Rotor winding short circuit faults are common faults for variable-speed pumped-storage generator-motors (VSPSGM). At present, the exciting rotor fault protection of VSPSGM is simple and has low sensitivity. It can only act when the instantaneous value of the rotor phase current reaches three times the rated current. Therefore, it is difficult to cover some rotor winding short-circuit faults with weak fault characteristics. It is urgent to study a novel rotor winding short-circuit-fault protection method for VSPSGM. In this paper, a protection method that combines the stator and rotor currents with different frequencies is proposed. The characteristics of the stator and rotor currents before and after the fault is analyzed by using Clark transformation. On this basis, a specific protection criterion is constructed based on the discrete integral operation, which is easy to implement and not affected by the change of rotor speed. Then, the calculation method of the protection setting is proposed, considering the effect of unbalanced voltage and sensor measurement error. Simulation results show that the proposed method can reliably realize the protection of rotor winding faults. It has faster protection action speed than other methods in the same field. The protection coverage rate is over 90%.
Floating nuclear power plants contain sensitive loads of nuclear reactors. After equipment faults, fast and efficient power supply recovery should be realized. To realize the unified analysis of system topology and power flow distribution, a power supply recovery strategy based on Petri nets is proposed. Considering that systems of different voltage levels cannot be connected instantaneously, a two-stage power supply recovery mode is adopted. Emergency power supply is put in first, and then the whole network is reconstructed. In the network reconstruction process, load transfer is realized through switching the transformation to redistribute the load of each switchboard and adjust the power output of each power source. Corresponding to the Petri net model, the above process is similar to the dynamic transmission process of a token in each library by firing the transition. Therefore, the topological model of system is constructed based on the Petri net, and a power flow analysis is proposed through its dynamic updating mechanism. The objective function of the network reconstruction is established by integrating load recovery amount, switch operation cost and generator operation efficiency, and the optimal switching state combination scheme that satisfies the system constraints is obtained by the multi-population genetic algorithm (MPGA). Simulation results show that the proposed method can provide complete power supply recovery.
Single-phase ground faults frequently occur at the generator stator windings. To realize reliable arc suppression, a dual-frequency active arc-suppression strategy has been widely considered. However, the existing method needs an inverter with large capacity, which is large in volume and high in cost, causing limited engineering application prospects. To reduce the capacity, a novel hybrid flexible neutral grounding method for large generators is proposed in this paper. It combines the dual-frequency active arc-suppression strategy with the arc-suppression coil-grounding mode. Thus, most of the fundamental components in the fault current are compensated by the arc-suppression coil, and the rest are compensated by the active arc-suppression device. The capacity of the inverter can be greatly reduced under the premise of reliably realizing arc suppression. To identify transient and permanent ground faults after arc suppression, the phase-angle relation between the third-harmonic voltage and current variation at the generator neutral point is used to form the fault-type identification criterion. The third-harmonic quantities can avoid the blind area at the neutral point caused by fundamental quantities. Simulation and experimental test results verify the effectiveness of the proposed method.