Vera Shavokshina

Dr. Vera Shavokshina

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2021 in ACS Applied Polymer Materials
Verified
Journal Article
Closed access
VSVera Shavokshina
Vera Shavokshina
MKMaria A. Komkova
Maria A. Komkova
IAIlya Aparin
Ilya Aparin
Timofei ZatsepinTimofei Zatsepin
Timofei Zatsepin
Arkady KaryakinArkady Karyakin
Arkady Karyakin
Egor A AndreevEgor A Andreev
Egor A Andreev

10 April 2024 in Journal of Electroanalytical Chemistry
Verified
Journal Article
Closed access
VSVera Shavokshina
Vera Shavokshina
VNVita N. Nikitina
Vita N. Nikitina
AKArkady A. Karyakin
Arkady A. Karyakin

12 December 2017 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
Egor A AndreevEgor A Andreev
Egor A Andreev
MKMaria A. Komkova
Maria A. Komkova
VSVera Shavokshina
Vera Shavokshina
DPDenis E. Presnov
Denis E. Presnov
VKVladimir A. Krupenin
Vladimir A. Krupenin
Arkady KaryakinArkady Karyakin
Arkady Karyakin

21 June 2024 in Journal of Analytical Chemistry
Verified
Journal Article
Closed access
PDF file
VSVera Shavokshina
Vera Shavokshina
AOA. Okoneshnikov
A. Okoneshnikov
VNV. Nikitina
V. Nikitina
AKA. Karyakin
A. Karyakin
Flow injection amperometry provides an opportunity to avoid common drawbacks of classical potentiometry for solid-contact ion-selective electrodes. The current is generated by solid-contact in course of the polymer chain recharging in response to an excess of cations or anions in the polymer film. Cations cause cathodic peaks on the chronoamperogram, while anions result in anodic peaks. For polyaniline with negatively charged substituents, a response to cations is observed, whereas the presence of uncharged ones results in anion detection. Moreover, in the case of the protonated –SO3H group, this compensating current is an order of magnitude lower than that for the deprotonated one. For electroactive self-doped polyanilines, the maximal amperometric signal is achieved at the working potential within the electroactivity range. The proposed constant potential amperometric approach was validated by the successful analysis of human serum with a Na+-selective electrode based on polyaniline.

2 May 2026 in Electrochimica Acta
Verified
Journal Article
Closed access
VSVera Shavokshina
Vera Shavokshina
VNVita N. Nikitina
Vita N. Nikitina
YMYulia A. Maksimova
Yulia A. Maksimova
EOEkaterina A. Omelchenko
Ekaterina A. Omelchenko
EIEgor K. Ignatov
Egor K. Ignatov
AKArkady A. Karyakin
Arkady A. Karyakin

25 September 2023 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
VSVera Shavokshina
Vera Shavokshina
VNVita Nikitina
Vita Nikitina
Arkady KaryakinArkady Karyakin
Arkady Karyakin
We report amperometric solid-contact potassium-selective electrodes based on catalytically synthesized Prussian Blue nanoparticles. Both the films and nanoparticles were able to generate an amperometric response in the flow-injection mode under a constant potential. However, the nanoparticles provided a higher sensitivity than the films. Moreover, the intrinsic permeability of Prussian Blue for potassium ions allowed for selective detection of potassium in comparison to sodium even without an ion-selective membrane. The results of electrochemical impedance spectroscopy were used to manage the sensitivity by controlling the charge transfer resistance for ion-selective membranes of different density. By performing measurements in Bis-Tris as a carrier buffer containing no interfering cations, an additional increase in selectivity was enabled. A record selectivity coefficient logK Na+/K+ of −2.7 for the amperometric flow-injection mode was achieved. The obtained results indicate the prospects for analysis of biological fluids as the Na+/K+ ratio is approximately 20–40.