Novel boron nitride (BN) fibers have been developed with diameters ranging from the nano- to microscale by thermal conversion of as-electrospun fibers from polyacrylonitrile and poly[B-(methylamino)borazine] blend solutions. Such a new class of ceramic fibers is seen as potential candidate for thermal management applications and filtration systems in harsh environments.
Hollow boron nitride nano-polyhedrons have been successfully prepared by annealing of boron nitride nanoparticles in a nitrogen atmosphere at 1800 °C without a catalyst. In our two-step process, we demonstrated that these boron nitride nanoparticles prepared by spray-pyrolysis of borazine are key precursors to grow these architectures. The samples were carefully analyzed using electron microscopies and Energy-Dispersive X-ray spectroscopy analysis. Based on such characterization tools, the growth mechanism of these architectures has been discussed and detailed. It is noteworthy that these nanostructures are generated via a solid-state transformation in relatively high yields without a metal catalyst and might open new opportunities in exploring chemical and physical properties.
11 October 2018 in ACS Biomaterials Science & Engineering
To prevent the uncontrolled development of a pathogenic biofilm around a dental implant, an antimicrobial drug-release electrospun membrane, set up between the implant and the gingival tissue, was developed by taking several technical, industrial and regulatory specifications into account. The membrane formulation is made of a blend of poly(l-lactic–co–gycolic acid) (PLGA, 85:15) and poly(l-lactic acide–co–ɛ-caprolactone) (PLC, 70:30) copolymers with chlorhexidine diacetate (CHX) complexed with β-cyclodextrin (CD). The amount of residual solvent, the mechanical properties and the drug release kinetics were tuned by the copolymers’ ratio, between 30% and 100% of PLC, and a CHX loading up to 20% w/w. The membranes were sterilized by γ-irradiation without significant property changes. The fiber′s diameter was between 600 nm and 3 µm, depending on the membrane composition and the electrospinning parameters. CHX was released in vitro over 10 days and the bacterial inhibitory concentration, 80 µg·mL−1, was reached within eight days. The optimal membrane, PGLA/PLC/CHX-CD (60%/40%/4%), exhibited a breaking strain of 50%, allowing its safe handling. This membrane and a membrane without CHX-CD were implanted subcutaneous in a rat model. The cell penetration remained low. The next step will be to increase the porosity of the membrane to improve the dynamic cell penetration and tissue remodeling.