Polypropylene mesh is used widely for surgical treatment of pelvic organ prolapse and stress urinary incontinence. Although these surgeries demonstrate favorable functional and anatomic outcomes, their use has been limited by complications, the 2 most common being exposure and pain. Growing evidence suggests that T lymphocytes play a critical role in the regulation of the host response to biomaterials. The purpose of this study was to define and characterize the T-cell response and to correlate the response to collagen deposition in fibrotic capsules in mesh tissue complexes that are removed for the complications of pain vs exposure. Patients who were scheduled to undergo a surgical excision of mesh for pain or exposure at Magee-Women's Hospital were offered enrollment. Forty-two mesh-vagina tissue complexes were removed for the primary complaint of exposure (n=24) vs pain (n=18). Twenty-one patients agreed to have an additional vaginal biopsy away from the site of mesh that served as control tissue. T cells were examined via immunofluorescent labeling for cell surface markers CD4+ (Th), CD8+ (cytotoxic) and foxp3 (T-regulatory cell). Frozen sections were stained with hematoxylin-eosin for gross morphologic condition and picrosirius red for collagen fiber analysis. Interrupted sodium-dodecyl sulfate gel electrophoresis was used to quantify the content of collagens type I and III, and the collagen III/I ratio. Transforming growth factor-β and connective tissue growth factor, which are implicated in the development of fibrosis, were measured via enzyme-linked immunosorbent assays. Data were analyzed with the Student's t tests, mixed effects linear regression, and Spearman's correlation coefficients. Demographic data were not different between groups, except for body mass index, which was 31.7 kg/m2 for the exposure group and 28.2 kg/m2 for pain (P=.04). Tissue complexes demonstrated a marked, but highly localized, foreign body response. We consistently observed a teardrop-shaped fibroma that encapsulated mesh fibers in both pain and exposure groups, with the T cells localized within the tip of this configuration away from the mesh-tissue interface. All 3 T-cell populations were significantly increased relative to control: CD4+ T helper (P<.001), foxp3+ T regulatory (P<.001), and CD8+ cytotoxic T cell (P=.034) in the exposure group. In the pain group, only T-helper (P<.001) and T-regulatory cells (P<.001) were increased, with cytotoxic T cells (P=.520) not different from control. Picrosirius red staining showed a greater area of green (thin) fibers in the exposure group (P=.025) and red (thick) fibers in the pain group (P<.001). The ratio of area green/(yellow + orange + red) that represented thin vs thick fibers was significantly greater in the exposure group (P=.005). Analysis of collagen showed that collagen type I was increased by 35% in samples with mesh complications (exposure and pain) when compared with control samples (P=.043). Strong correlations between the profibrosis cytokine transforming growth factor-β and collagen type I and III were found in patients with pain (r≥0.833; P=.01) but not exposure (P>.7). T cells appear to play a critical role in the long-term host response to mesh and may be a central pathway that leads to complications. The complexity of this response warrants further investigation and has the potential to broaden our understanding of mesh biology and clinical outcomes.
1 June 2021 in American Journal of Obstetrics and Gynecology
This study's aim was to determine whether the inclusion of superficial perineal structures in a finite-element simulation of vaginal delivery impacts the pubovisceral muscle and perineal body, two common sites of birth-related injury. The hypothesis, inferred from prevailing literature, was that these structures would have minimal influence (differences less than ±10%). Two models were made using the Visible Human Project's female cadaver to create a rigid, fixed pelvis, musculature held by spring attachments to that pelvis, and a rigid, ellipsoidal fetal head prescribed with an inferior displacement to simulate delivery. Injury site stretch ratios and fetal head and perineal body displacements and angles of progression were compared between the Omitted Model (which excluded the superficial perineal structures as is common practice) and the Included Model (which included them). Included Model stretch ratios were +107%, −9.84% and −14.6% compared to Omitted Model perineal body and right and left pubovisceral muscles, respectively. Included Model peak perineal body inferior displacement was +72.5% greater while similar anterior–posterior displacements took longer to reach. These results refute our hypothesis, suggesting superficial perineal structures impact simulations of vaginal delivery by inhibiting perineal body anterior–posterior displacement, which stretches and inferiorly displaces the perineal body.
Pelvic organ prolapse (POP) surgical repair with polypropylene mesh (PPM) offers improved anatomical outcomes compared to reconstruction using native tissue. However, PPM repair is hampered by complications, most commonly pain or mesh exposure, occurring in over 10 % of cases. This maladaptive response is, in part, attributed to the host response to a foreign material. Previous studies have demonstrated that mesh properties, such as weight, pore size, and porosity, influence downstream outcomes. In addition, computational models and in vivo mechanistic studies demonstrate that mesh deforms after tensioning in prolapse surgery resulting in collapsed pores and wrinkles. To further investigate the role of pore collapse in mesh complications, PPM was implanted flat, or in configurations that would deform upon tensioning in a POP repair surgery using a non-human primate model. After twelve weeks, we analyzed mesh-tissue complexes to characterize the overall host response, profile the macrophage response, and observe the influence of macrophages in downstream healing outcomes that may lead to complications. The results confirm that mesh deformations reproduce mesh exposure and thinning of vagina. In the PPM configurations with the greatest deformation, mesh burden was the highest, which resulted in an overall decrease in the number of cells within the implantation site. Among the cells that were present, we observed a predominance of M1 pro-inflammatory macrophages. While flat mesh was associated with an organized cellular response, deformed mesh led to an increasingly disorganized response as mesh burden increased. Nearly half of the responding macrophages expressed markers associated both with M1 and M2 phenotypes concurrently, suggesting the possibility of newly recruited macrophages responding even 12 weeks after implantation and/or a repetitive microinjury in which macrophages are continuously recruited and polarized without resolution of the host response. Biochemically, we observed a predominantly M1 pro-inflammatory signaling environment and decreased collagen content as a response to implanted mesh. This study evidences the importance of PPM mesh properties, which may alter mesh burden upon tensioning and impact downstream healing outcomes and emphasizes the need for devices that maintain their geometry following implantation in POP surgical repair.