Zhifeng Cheng

Dr. Zhifeng Cheng


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
XLXiaohan Liu
Xiaohan Liu
KGKaihui Gu
Kaihui Gu
MLMeixuan Li
Meixuan Li
ZCZhifeng Cheng
Zhifeng Cheng
Lightweight, high stability, and high-temperature adaptability are the primary considerations when designing the primary mirror of a micro/nano satellite remote sensing camera. In this paper, the optimized design and experimental verification of the large-aperture primary mirror of the space camera with a diameter of Φ610 mm is carried out. First, the design performance index of the primary mirror was determined according to the coaxial tri-reflective optical imaging system. Then, SiC, with excellent comprehensive performance, was selected as the primary mirror material. The initial structural parameters of the primary mirror were obtained using the traditional empirical design method. Due to the improvement of SiC material casting complex structure reflector technology level, the initial structure of the primary mirror was improved by integrating the flange with the primary mirror body design. The support force acts directly on the flange, changing the transmission path of the traditional back plate support force, and has the advantage that the primary mirror surface shape accuracy can be maintained for a long time when subjected to shock, vibration, and temperature changes. Then, a parametric optimization algorithm based on the mathematical method of compromise programming was used to optimize the design of the initial structural parameters of the improved primary mirror and the flexible hinge, and finite element simulation was conducted on the optimally designed primary mirror assembly. Simulation results show that the root mean square (RMS) surface error is less than λ/50 (λ = 632.8 nm) under gravity, 4 °C temperature rise, and 0.01 mm assembly error. The mass of the primary mirror is 8.66 kg. The maximum displacement of the primary mirror assembly is less than 10 μm, and the maximum inclination angle is less than 5″. The fundamental frequency is 203.74 Hz. Finally, after the primary mirror assembly was precision manufactured and assembled, the surface shape accuracy of the primary mirror was tested by ZYGO interferometer, and the test value was 0.02 λ. The vibration test of the primary mirror assembly was conducted at a fundamental frequency of 208.25 Hz. This simulation and experimental results show that the optimized design of the primary mirror assembly meets the design requirements of the space camera.

19 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
FLFuhe Liu
Fuhe Liu
ZCZhifeng Cheng
Zhifeng Cheng
PJPing JIA
Ping JIA
BZBao Zhang
Bao Zhang
XLXiaofeng Liu
Xiaofeng Liu
RHRizha Hu
Rizha Hu
The image resolution is the most important performance parameter for an aerial optoelectronic sensor. Existing thermal control methods cannot eliminate the sensor’s temperature gradient, making the image resolution difficult to further improve. This article analyzes the different impacts of temperature changes on the imaging resolution and proposes modifications. Firstly, the sensor was subjected to thermo-optical simulation by means of finite element analysis, and the different impacts of temperature changes on the imaging quality were analyzed. According to the simulation results, an active thermal control method is suggested to enhance the temperature uniformity of the sensor. Considering the impacts of active and passive thermal control measures, thermal optical analysis was carried out to predict the performance of the sensor. The results of the analysis show that the imaging quality of the sensor has been significantly improved. The experimental results show that the image resolution of the optoelectronic sensor improved from 47 to 59 lp/mm, which demonstrates that the sensor can produce a high image quality in a low-temperature environment.

28 November 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ZCZhifeng Cheng
Zhifeng Cheng
LSLu Sun
Lu Sun
FLFuhe Liu
Fuhe Liu
XLXiaofeng Liu
Xiaofeng Liu
LLLei Li
Lei Li
RHRicha Hu
Richa Hu
In order to ensure the imaging performance of the aerial optoelectronic platform system in low temperature environment, an active-passive combined thermal control technology was studied. A thermal control finite element model of the aerial optoelectronic platform was established. Additionally, thermal control simulation analysis and experiments under extreme conditions were carried out respectively. The simulation and experimental results showed that the temperature level of the primary mirror is improved above 25 °C by the proposed thermal control technology effectively, meanwhile the temperature gradient of the primary and secondary mirrors are less than 5 °C. The successful implementation of this active-passive combined thermal control technology provides a technical support for the precision thermal control of aerial optoelectronic platforms.

16 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
XLXiaohan Liu
Xiaohan Liu
JJJian Jiao
Jian Jiao
KGKaihui Gu
Kaihui Gu
HLHong Li
Hong Li
WZWenying Zhang
Wenying Zhang
FYFeng Yang
Feng Yang
To meet the requirements of high resolution, compact size, and ultra-lightweight for micro–nano satellite optoelectronic payloads while ensuring high structural stability during launch and in-orbit operation, mirrors were designed with high surface accuracy. The opto-thermo-mechanical system of the space camera was designed and analyzed accordingly. First, an optical system was designed to achieve high resolution and a compact form factor. A coaxial triple-reflector configuration with multiple refractive paths was adopted, which significantly shortened the optical path and laid the foundation for a lightweight, compact structure. This design also defined the accuracy and tolerance requirements for the primary and secondary mirrors. Subsequently, mathematical models for topology optimization and dimensional optimization were established to optimize the design of the main support structure, primary mirror, and secondary mirror. Two design schemes for the main support structure and primary mirror were compared. Steady-state thermal analysis and thermal control design were carried out for both mirrors. Simulations were then performed on the main system (including the primary/secondary mirror assemblies and the main support structure). Under the combined effects of gravity, a 4 °C temperature increase, and an assembly flatness deviation of 0.01 mm, the surface accuracy of both mirrors, the displacement of the secondary mirror relative to the primary mirror reference, and the tilt angle all met the overall specification requirements. The system’s first-order natural frequency was 156.731 Hz. After precision machining, fabrication, and assembly, wavefront aberration testing was conducted on the main system with the optical axis horizontal. Under gravity, the root mean square (RMS) wavefront error at the center of the field of view was 0.073λ, satisfying the specification of ≤1/14λ. The fundamental frequency measured during vibration testing was 153.09 Hz, which aligned closely with the simulated value and well exceeded the requirement of 100 Hz. Additionally, in-orbit imaging verification was conducted. All results satisfied the technical specifications of the satellite’s overall requirements.