Davide Allegro

Dr. Davide Allegro

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2024 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
DADavide Allegro
Davide Allegro
MTMatteo Terreran
Matteo Terreran
Stefano GhidoniStefano Ghidoni
Stefano Ghidoni
In industrial scenarios, effective human-robot collaboration relies on multi-camera systems to robustly monitor human operators despite the occlusions that typically show up in a robotic workcell. In this scenario, precise localization of the person in the robot coordinate system is essential, making the hand-eye calibration of the camera network critical. This process presents significant challenges when high calibration accuracy should be achieved in short time to minimize production downtime, and when dealing with extensive camera networks used for monitoring wide areas, such as industrial robotic workcells. Our paper introduces an innovative and robust multi-camera hand-eye calibration method, designed to optimize each camera's pose relative to both the robot's base and to each other camera. This optimization integrates two types of key constraints: i) a single board-to-end-effector transformation, and ii) the relative camera-to-camera transformations. We demonstrate the superior performance of our method through comprehensive experiments employing the METRIC dataset and real-world data collected on industrial scenarios, showing notable advancements over state-of-the-art techniques even using less than 10 images. Additionally, we release an open-source version of our multi-camera hand-eye calibration algorithm at https://github.com/davidea97/Multi-Camera-Hand-Eye-Calibration.git

12 May 2025
Verified
Book Chapter
Closed access
PDF file
LBLaura Bragagnolo
Laura Bragagnolo
MTMatteo Terreran
Matteo Terreran
DADavide Allegro
Davide Allegro
Stefano GhidoniStefano Ghidoni
Stefano Ghidoni


29 May 2023 in Information
Verified
Journal Article
Open access
PDF file
DADavide Allegro
Davide Allegro
MTMatteo Terreran
Matteo Terreran
Stefano GhidoniStefano Ghidoni
Stefano Ghidoni
Multi-camera systems are an effective solution for perceiving large areas or complex scenarios with many occlusions. In such a setup, an accurate camera network calibration is crucial in order to localize scene elements with respect to a single reference frame shared by all the viewpoints of the network. This is particularly important in applications such as object detection and people tracking. Multi-camera calibration is a critical requirement also in several robotics scenarios, particularly those involving a robotic workcell equipped with a manipulator surrounded by multiple sensors. Within this scenario, the robot-world hand-eye calibration is an additional crucial element for determining the exact position of each camera with respect to the robot, in order to provide information about the surrounding workspace directly to the manipulator. Despite the importance of the calibration process in the two scenarios outlined above, namely (i) a camera network, and (ii) a camera network with a robot, there is a lack of standard datasets available in the literature to evaluate and compare calibration methods. Moreover they are usually treated separately and tested on dedicated setups. In this paper, we propose a general standard dataset acquired in a robotic workcell where calibration methods can be evaluated in two use cases: camera network calibration and robot-world hand-eye calibration. The Multi-Eye To Robot Indoor Calibration (METRIC) dataset consists of over 10,000 synthetic and real images of ChAruCo and checkerboard patterns, each one rigidly attached to the robot end-effector, which was moved in front of four cameras surrounding the manipulator from different viewpoints during the image acquisition. The real images in the dataset includes several multi-view image sets captured by three different types of sensor networks: Microsoft Kinect V2, Intel RealSense Depth D455 and Intel RealSense Lidar L515, to evaluate their advantages and disadvantages for calibration. Furthermore, in order to accurately analyze the effect of camera-robot distance on calibration, we acquired a comprehensive synthetic dataset, with related ground truth, with three different camera network setups corresponding to three levels of calibration difficulty depending on the cell size. An additional contribution of this work is to provide a comprehensive evaluation of state-of-the-art calibration methods using our dataset, highlighting their strengths and weaknesses, in order to outline two benchmarks for the two aforementioned use cases.

28 August 2024 in arXiv
Verified
Preprint
Open access
PDF file
LBLaura Bragagnolo
Laura Bragagnolo
MTMatteo Terreran
Matteo Terreran
DADavide Allegro
Davide Allegro
Stefano GhidoniStefano Ghidoni
Stefano Ghidoni
Robust 3D human pose estimation is crucial to ensure safe and effective human-robot collaboration. Accurate human perception,however, is particularly challenging in these scenarios due to strong occlusions and limited camera viewpoints. Current 3D human pose estimation approaches are rather vulnerable in such conditions. In this work we present a novel approach for robust 3D human pose estimation in the context of human-robot collaboration. Instead of relying on noisy 2D features triangulation, we perform multi-view fusion on 3D skeletons provided by absolute monocular methods. Accurate 3D pose estimation is then obtained via reprojection error optimization, introducing limbs length symmetry constraints. We evaluate our approach on the public dataset Human3.6M and on a novel version Human3.6M-Occluded, derived adding synthetic occlusions on the camera views with the purpose of testing pose estimation algorithms under severe occlusions. We further validate our method on real human-robot collaboration workcells, in which we strongly surpass current 3D human pose estimation methods. Our approach outperforms state-of-the-art multi-view human pose estimation techniques and demonstrates superior capabilities in handling challenging scenarios with strong occlusions, representing a reliable and effective solution for real human-robot collaboration setups.

10 September 2025 in arXiv
Verified
Preprint
Open access
PDF file
DADavide Allegro
Davide Allegro
MTMatteo Terreran
Matteo Terreran
SGStefano Ghidoni
Stefano Ghidoni
Robots often rely on RGB images for tasks like manipulation and navigation. However, reliable interaction typically requires a 3D scene representation that is metric-scaled and aligned with the robot reference frame. This depends on accurate camera-to-robot calibration and dense 3D reconstruction, tasks usually treated separately, despite both relying on geometric correspondences from RGB data. Traditional calibration needs patterns, while RGB-based reconstruction yields geometry with an unknown scale in an arbitrary frame. Multi-camera setups add further complexity, as data must be expressed in a shared reference frame. We present Calib3R, a patternless method that jointly performs camera-to-robot calibration and metric-scaled 3D reconstruction via unified optimization. Calib3R handles single- and multi-camera setups on robot arms or mobile robots. It builds on the 3D foundation model MASt3R to extract pointmaps from RGB images, which are combined with robot poses to reconstruct a scaled 3D scene aligned with the robot. Experiments on diverse datasets show that Calib3R achieves accurate calibration with less than 10 images, outperforming target-less and marker-based methods.