Class imbalance exists widely in partial discharge (PD) diagnosis of gas-insulated switchgear (GIS). On the one hand, while atypical PDs occur sometimes but the sample is scarce. On the other hand, due to the contingency and concurrency of PDs, the demand for multi-source PD increases exponentially, making it difficult to obtain sufficient data. This study focuses on zero-shot diagnosis in extreme cases where only typical defects are available and where atypical and multi-source PDs are not available during training. And we propose a semantic rectifying discriminative generative adversarial network (SRDGAN) for zero-shot diagnosis. The proposed SRDGAN trains the generator from the visible samples and semantic attributes, and generates the unseen samples from the unseen semantic attributes and trains the classifier for zero-shot diagnosis. First, a semantic rectifying module is designed to correct the structure between the visual and semantic space to make the semantic features distinguishable. Then, the latent discriminative attributes are extracted from the visual features, and an attribute embedding module is designed. Finally, PD diagnosis is performed on feature generation and classification modules. The proposed SRDGAN is validated on two datasets. The experimental results illustrate that the SRDGAN solves zero-sample GIS PD diagnosis with >90% accuracy.
Deep learning methods, especially convolutional neural networks (CNNs), have achieved good results in the partial discharge (PD) diagnosis of gas-insulated switchgear (GIS) in the laboratory. However, the relationship of features ignored in CNNs and the heavy dependance on the amount of sample data make it difficult for the model developed in the laboratory to achieve high-precision, robust diagnosis of PD in the field. To solve these problems, a subdomain adaptation capsule network (SACN) is adopted for PD diagnosis in GIS. First, the feature information is effectively extracted by using a capsule network, which improves feature representation. Then, subdomain adaptation transfer learning is used to accomplish high diagnosis performance on the field data, which alleviates the confusion of different subdomains and matches the local distribution at the subdomain level. Experimental results demonstrate that the accuracy of the SACN in this study reaches 93.75% on the field data. The SACN has better performance than traditional deep learning methods, indicating that the SACN has potential application value in PD diagnosis of GIS.
With the rapid development of deep learning, its powerful capabilities make it possible to perform mechanical fault diagnosis of high-voltage circuit breakers (HVCBs). Among deep learning approaches, the convolutional neural network is widely used. However, while it can extract features effectively, it also has some limitations. Specifically, it depends on a large number of training data and only takes data information into account without considering structural information. These shortcomings lead to unused information and unsatisfactory model results. To address these shortcomings, this paper proposes AKNN-DMGCN, a novel dynamic multi-attention graph convolutional network based on an adaptively constructed graph, which can achieve high accuracy and robust mechanical fault diagnosis of HVCBs. First, a novel adaptive k-nearest neighbor (AKNN) graph construction method is proposed to construct informative graphs. The AKNN method can mine the relationship between the original data samples and utilize the data and label information. Thus, it has high fault tolerance to noise signals and can construct a structure graph with rich and accurate information, which can improve the overall model performance. Then, a dynamic multi-attention graph convolutional network (DMGCN) is applied for mechanical fault diagnosis of HVCBs. DMGCN fully utilizes structural and numerical information representing HVCB signals to perform classification. DMGCN has a dynamic multi-attention mechanism with strong expressive ability, which allows it to achieve high diagnostic accuracy. The experimental results indicate that the accuracy of AKNN-DMGCN reaches 97.22% on a balanced dataset and 95.01% on an imbalanced dataset, which demonstrates that the proposed method is effective for both balanced and imbalanced samples.
High-voltage circuit breakers (HVCBs) handle the important tasks of controlling and safeguarding electricity networks. In the case of insufficient data samples, improving the accuracy of the traditional HVCB mechanical fault diagnosis method is difficult, so it poses challenges in meeting performance requirements for mechanical fault diagnosis. In this study, a HVCB fault diagnosis method is introduced. It utilizes a combination of grey wolf optimization (GWO) and multi-grained cascade forest (gcForest) algorithms to resolve these issues and improve the accuracy of HVCB mechanical fault diagnosis. To simplify the original vibration signal, the input feature quantity for the fault diagnosis method is obtained by calculating the energy entropy of the wavelet packet decomposition. The GWO algorithm is employed to optimize the parameters of the gcForest model, leading to identification of the optimum parameter configuration. Subsequently, the diagnostic effect in the case of a small sample size was analyzed through a VS1 vacuum circuit breaker example, and the accuracy reached 95.89%. In the case of unbalanced samples, further analysis and comparison with different methods confirm the feasibility and efficiency of the combination of GWO and gcForest algorithms. This study provides an effective solution for the diagnosis of mechanical faults in HVCBs.