1 March 2012 in RadioGraphics
Verified
Journal Article
Closed access
RKRavi K. Kaza
Ravi K. Kaza
JPJoel F. Platt
Joel F. Platt
RCRichard H. Cohan
Richard H. Cohan
ECElaine M. Caoili
Elaine M. Caoili
MAMahmoud M. Al-Hawary
Mahmoud M. Al-Hawary
AWAshish Pandhari Wasnik
Ashish Pandhari Wasnik
Several promising clinical applications for dual-energy computed tomography (CT) in genitourinary imaging have been reported. Dual-energy CT not only provides excellent morphologic detail but also can supply material-specific and quantitative information that may be particularly useful in genitourinary imaging. Dual-energy CT has unique capabilities for characterizing renal lesions by quantifying iodine content and helping identify the mineral contents of renal stones, information that is important for patient care. Virtual unenhanced images reconstructed from dual-energy CT datasets can be useful for detecting calculi within the iodine-filled urinary collecting system, potentially reducing the need for an unenhanced scanning phase at CT urography. Although the underlying principles of dual-energy CT are the same regardless of scanner type, single-source dual-energy scanners with fast kilovoltage switching differ from dual-source dual-energy scanners both in image data acquisition and in processing methods; an understanding of these differences may help optimize dual-energy CT genitourinary protocols. Dual-energy CT performed with a dual-source scanner or with a single-source scanner with fast kilovoltage switching also has some important limitations. Further advances in scanning protocols and refinement of processing techniques to reduce image noise may lead to more widespread use of dual-energy CT.

1 July 2014 in Radiology
Verified
Journal Article
Closed access
MDMatthew S. Davenport
Matthew S. Davenport
SKShokoufeh Khalatbari
Shokoufeh Khalatbari
PLPeter S. C. Liu
Peter S. C. Liu
KMKatherine E. Maturen
Katherine E. Maturen
RKRavi K. Kaza
Ravi K. Kaza
HHHero K. Hussain
Hero K. Hussain
Of three major qualitative MR imaging features for hepatocellular carcinoma, two (washout appearance and pseudocapsule) have only moderate interreader agreement. PurposeTo determine for expert and novice radiologists repeatability of major diagnostic features and scoring systems (ie, Liver Imaging Reporting and Data System [LI-RADS], Organ Procurement and T...

1 June 2019 in Academic Radiology
Verified
Journal Article
Closed access
ADAndrew J. Degnan
Andrew J. Degnan
EGEmily H. Ghobadi
Emily H. Ghobadi
PHPeter Hardy
Peter Hardy
EKElizabeth Krupinski
Elizabeth Krupinski
ESElena P. Scali
Elena P. Scali
WAWilliam F. Auffermann
William F. Auffermann

1 July 2012 in American Journal of Roentgenology
Verified
Journal Article
Closed access
RORyan B O'Malley
Ryan B O'Malley
MAMahmoud M Al-Hawary
Mahmoud M Al-Hawary
RKRavi K Kaza
Ravi K Kaza
AWAshish Pandhari Wasnik
Ashish Pandhari Wasnik
PLPeter S Liu
Peter S Liu
HHHero K Hussain
Hero K Hussain
OBJECTIVE. The purpose of this article is to provide an overview of pelvic MRI for the evaluation of perianal fistulas, with a description of the technique, illustration of relevant normal anatomy, and examples of various fistula types. CONCLUSION. MRI evaluation of perianal fistulas can be challenging, and knowledge of relevant pelvic anatomy and fistula classification remains crucial in the diagnosis. MRI is highly accurate for fistula depiction and, by providing an accurate assessment of disease status and extension, can help surgical planning to minimize recurrence and detect clinically unapparent disease.

1 May 2012 in American Journal of Roentgenology
Verified
Journal Article
Closed access
RKRavi K. Kaza
Ravi K. Kaza
JPJoel F. Platt
Joel F. Platt
MAMahmoud M. Al-Hawary
Mahmoud M. Al-Hawary
AWAshish Pandhari Wasnik
Ashish Pandhari Wasnik
PLPeter S. Liu
Peter S. Liu
APAmit Pandya
Amit Pandya
OBJECTIVE. The objective of our study was to evaluate the image quality and diagnostic adequacy of the following two CT enterography protocols in patients weighing less than 160 lb (72 kg): 80-kVp imaging with the adaptive statistical iterative reconstruction (ASIR) in comparison with 120-kVp imaging with the filtered back projection reconstruction. MATERIALS AND METHODS. We retrospectively reviewed 133 CT enterography examinations of 127 patients weighing less than 160 lb, 64 80-kVp examinations, and 69 120-kVp examinations. Image quality for evaluation of the bowel wall, mesenteric vessels, and hepatic parenchyma and the overall image quality were graded on a scale of 1–5 (1 = poor, 2 = acceptable, 3 = good, 4 = very good, 5 = excellent). Diagnostic accuracy for the detection of inflammatory bowel disease was evaluated. The volume CT dose index (CTDIvol) was recorded and effective dose was calculated from scanner-generated dose-length product. RESULTS. There was a statistically significant decrease in the mean image quality scores for 80-kVp examinations compared with 120-kVp examinations for evaluation of the bowel wall (3.19 vs 3.70, respectively) and liver (3.12 vs 3.81) and for overall image quality (3.23 vs 3.68), but there was no significant decrease in score for evaluation of the mesenteric vessels (3.63 vs 3.67). None of the 80-kVp examinations was graded as poor, and all were considered to be of acceptable quality. Both techniques had comparable diagnostic accuracy for the detection of inflammatory bowel disease. Interobserver agreement was fair to moderate for qualitative image grading and was substantial for the detection of features of inflammatory bowel disease. The mean CTDIvol and effective dose for the 80-kVp examinations were 6.15 mGy and 4.60 mSv, respectively, and for the 120-kVp examinations, 20.79 mGy and 15.81 mSv. CONCLUSION. In patients weighing less than 160 lb, CT enterography examinations at 80 kVp with 30% ASIR produce diagnostically acceptable image quality with an average CTDIvol of 6.15 mGy and an average effective dose of 4.60 mSv.

1 January 2014 in RadioGraphics
Verified
Journal Article
Closed access
RKRavi K. Kaza
Ravi K. Kaza
JPJoel F. Platt
Joel F. Platt
MGMitchell M. Goodsitt
Mitchell M. Goodsitt
MAMahmoud M. Al-Hawary
Mahmoud M. Al-Hawary
KMKatherine E. Maturen
Katherine E. Maturen
APAmit Pandya
Amit Pandya
Recent advances in computed tomographic (CT) scanning technique such as automated tube current modulation (ATCM), optimized x-ray tube voltage, and better use of iterative image reconstruction have allowed maintenance of good CT image quality with reduced radiation dose. ATCM varies the tube current during scanning to account for differences in patient attenuation, ensuring a more homogeneous image quality, although selection of the appropriate image quality parameter is essential for achieving optimal dose reduction. Reducing the x-ray tube voltage is best suited for evaluating iodinated structures, since the effective energy of the x-ray beam will be closer to the k-edge of iodine, resulting in a higher attenuation for the iodine. The optimal kilovoltage for a CT study should be chosen on the basis of imaging task and patient habitus. The aim of iterative image reconstruction is to identify factors that contribute to noise on CT images with use of statistical models of noise (statistical iterative reconstruction) and selective removal of noise to improve image quality. The degree of noise suppression achieved with statistical iterative reconstruction can be customized to minimize the effect of altered image quality on CT images. Unlike with statistical iterative reconstruction, model-based iterative reconstruction algorithms model both the statistical noise and the physical acquisition process, allowing CT to be performed with further reduction in radiation dose without an increase in image noise or loss of spatial resolution. Understanding these recently developed scanning techniques is essential for optimization of imaging protocols designed to achieve the desired image quality with a reduced dose.