Héctor Guerrero

Dr. Héctor Guerrero

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Engineering Structures
Verified
Journal Article
Closed access
HGHéctor Guerrero
Héctor Guerrero
TJTianjian Ji
Tianjian Ji
JEJ. Alberto Escobar
J. Alberto Escobar
ATAmador Teran-Gilmore
Amador Teran-Gilmore

1 October 2017 in Journal of Constructional Steel Research
Verified
Journal Article
Closed access
HGHéctor Guerrero
Héctor Guerrero
JRJorge Ruíz-García
Jorge Ruíz-García
JEJ. Alberto Escobar
J. Alberto Escobar
ATAmador Terán-Gilmore
Amador Terán-Gilmore

14 July 2022 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
ETEdgar Tapia-Hernández
Edgar Tapia-Hernández
ASAlejandro Santiago-Flores
Alejandro Santiago-Flores
HGHéctor Guerrero
Héctor Guerrero

18 May 2020 in Experimental Techniques
Verified
Journal Article
Closed access
PDF file
HGHéctor Guerrero
Héctor Guerrero
ATA. Teran-Gilmore
A. Teran-Gilmore
EZE. Zamora
E. Zamora
JEJ.A. Escobar
J.A. Escobar
RGR. Gómez
R. Gómez

1 June 2025 in Journal of Building Engineering
Verified
Journal Article
Closed access
MCMing-Chieh Chuang
Ming-Chieh Chuang
ETEdgar Tapia-Hernández
Edgar Tapia-Hernández
KCKai-Ning Chi
Kai-Ning Chi
HLHuang-Zuo Lin
Huang-Zuo Lin
JLJui-Liang Lin
Jui-Liang Lin
CMChung-Chun Ma
Chung-Chun Ma

18 May 2023 in Buildings
Verified
Journal Article
Open access
PDF file
CLCyprien Lubin
Cyprien Lubin
HGHéctor Guerrero
Héctor Guerrero
SASergio M. Alcocer
Sergio M. Alcocer
OBOscar Lopez Batiz
Oscar Lopez Batiz
Results of an experimental program of 13 confined masonry walls rehabilitated with different techniques are presented. All specimens were built to full-scale with an aspect ratio (height to length) of 1. Vertical confining elements of one wall were built with 6.4 mm diameter welded wire reinforcing cages. Before rehabilitation, 11 of the 13 walls were initially tested to induce repairable damage; the other 2 were strengthened in an undamaged state. During testing, walls were subjected to a constant vertical load. Initially, damaged walls were rehabilitated using various techniques, such as jacketing made of mortar and welded wire mesh and synthetic or steel fibers. One initially damaged wall was rehabilitated with premixed mortar and fiberglass mesh. After rehabilitation, specimens were tested for failure. The experimental program is discussed, including materials characterization and main test results. Recommendations to practicing engineers involved in rehabilitating earthquake-damaged masonry structures are presented. It was found that the original capacity of the walls, in terms of strength, stiffness, and deformation, was increased considerably using the studied techniques. It is concluded that the techniques evaluated in this project are adequate for the seismic rehabilitation of masonry structures.