David Martin

Prof. David Martin

orcid

Research Focus & Metrics

Academic Career Length

41Years (1986-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2005 in Experimental Neurology
Verified
Journal Article
Closed access
RBRoy Biran
Roy Biran
DMDavid Martin
David Martin
PTPatrick A. Tresco
Patrick A. Tresco

25 January 2006 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
MAM. R. Abidian
M. R. Abidian
DKD.‐H. Kim
D.‐H. Kim
DMDavid Martin
David Martin

25 September 2005 in Nature Materials
Verified
Journal Article
Closed access
KRKyung-Ho Roh
Kyung-Ho Roh
DMDavid Martin
David Martin
JLJoerg Lahann
Joerg Lahann

1 March 2006 in Journal of Neural Engineering
Verified
Journal Article
Closed access
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
JUJeffrey D Uram
Jeffrey D Uram
JYJunyan Yang
Junyan Yang
DMDavid Martin
David Martin
DKDaryl R Kipke
Daryl R Kipke
Conductive polymer coatings can be used to modify traditional electrode recording sites with the intent of improving the long-term performance of cortical microelectrodes. Conductive polymers can drastically decrease recording site impedance, which in turn is hypothesized to reduce thermal noise and signal loss through shunt pathways. Moreover, conductive polymers can be seeded with agents aimed at promoting neural growth toward the recording sites or minimizing the inherent immune response. The end goal of these efforts is to generate an ideal long-term interface between the recording electrode and surrounding tissue. The goal of this study was to refine a method to electrochemically deposit surfactant-templated ordered poly(3,4-ethylenedioxythiophene) (PEDOT) films on the recording sites of standard 'Michigan' probes and to evaluate the efficacy of these modified sites in recording chronic neural activity. PEDOT-coated site performance was compared to control sites over a six-week evaluation period in terms of impedance spectroscopy, signal-to-noise ratio, number of viable unit potentials recorded and local field potential recordings. PEDOT sites were found to outperform control sites with respect to signal-to-noise ratio and number of viable unit potentials. The benefit of reduced initial impedance, however, was mitigated by the impedance contribution of typical silicon electrode encapsulation. Coating sites with PEDOT also reduced the amount of low-frequency drift evident in local field potential recordings. These findings indicate that electrode sites electrochemically deposited with PEDOT films are suitable for recording neural activity in vivo for extended periods. This study also provided a unique opportunity to monitor how neural recording characteristics develop over the six weeks following implantation.

1 December 1999 in Polymer
Verified
Journal Article
Closed access
CBChristopher J. Buchko
Christopher J. Buchko
LCLoui C. Chen
Loui C. Chen
YSYu Shen
Yu Shen
DMDavid Martin
David Martin

1 March 2003 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
XCXinyan Cui
Xinyan Cui
DMDavid Martin
David Martin