Arsenic-containing hydrocarbons (AsHCs) are common constituents of marine organisms and have potential toxicity to human health. This work is to study the effect of AsHCs on long-term potentiation (LTP) for the first time. A multi-electrode array (MEA) system was used to record the field excitatory postsynaptic potential (fEPSP) of CA1 before and after treatment with AsHC 360 in hippocampal slices from infantile male rats. The element content of Na, K, Ca, Mg, Mn, Cu, Zn, and As in the hippocampal slices were analyzed by elemental mass spectrometry after the neurophysiological experiment. The results showed that low AsHC 360 (1.5 μg As L-1) had no effect on the LTP, moderate AsHC 360 (3.75-15 μg As L-1) enhanced the LTP, and high AsHC 360 (45-150 μg As L-1) inhibited the LTP. The enhancement of the LTP by promoting Ca2+ influx was proved by a Ca2+ gradient experiment. The inhibition of the LTP was likely due to damage of synaptic cell membrane integrity. This study on the neurotoxicity of AsHCs showed that high concentrations have a strong toxic effect on the LTP in hippocampus slices of the infantile male rat, which may lead to a negative effect on the development, learning, and memory.
6 July 2023 in IEEE Transactions on Instrumentation and Measurement
In this article, a wireless passive micro-magnetic stimulation (WP-μMS) for isolated hippocampal slices is designed. Wireless power transmission (WPT) is used to couple the energy from the transmitting coil into the micro-coil to achieve magnetic stimulation for the cell. However, the critical issue involved here is to improve the signal-to-noise ratio (SNR) of the micro-coil stimulation target and reach the threshold of effective magnetic stimulation. First, the magnetic coupling resonance WPT theory and finite element analysis model of the WP-μMS are established. The transmission efficiency and mutual inductance of the WP-μMS are measured at different resonant frequencies. Second, the magnetic field strength and magnetic field distribution regularity of the stimulated targets in hippocampal brain slices are analyzed. The system achieves a WPT efficiency of 39.58% at a resonance frequency of 920 kHz with a guaranteed threshold of 1 mT effective magnetic field strength generated by the micro-coil. Last, biological experiments based on isolated hippocampal brain slices are performed for validation. The results show that the WP-μMS enhances the synaptic plasticity long-term potentiation (LTP) in the hippocampal CA1 region.
1 September 2022 in Review of Scientific Instruments
Micro-magnetic stimulation is a research hotspot in the field of neuromodulation. However, it is difficult to measure the weak magnetic field produced by a millimeter-sized inductor. In this study, a mutual inductance model considering different positions and sizes was established for a common planar square spiral coil micro-magnetic stimulator. A physical model was simulated using the Comsol finite element method to verify the accuracy of the mutual inductance model. A weak magnetic field detection system was constructed using the TI AD8130 and NE5532 chips, and the magnetic field strengths of excitation micro-coils sized 3.612 × 3.612 and 5.55 × 5.55 mm2 were measured. The results show that when the size ratio of the detection coil (DC) to the excitation coil (EC) is under a specific ratio (DC:EC = 1:1, 2:1, 1.53:1,2.36:1), the measurement range of the magnetic field strength is in the range 0–3.06 mT with an error of 0.05 mT, and the frequency is in the range 1–120 kHz. The measurement accuracy rate reaches 97.62%. The results of this study have potential application in the measurement of the weak magnetic field.
Arsenic-containing hydrocarbons (AsHCs) are typical arsenolipids found in various marine organisms. They can penetrate the blood–brain barrier, specifically affecting synaptic plasticity and the learning and memory ability of hippocampal neurons. Temporal lobe epilepsy often occurs in the hippocampus. Thus, the possible influence of AsHCs exposure to temporal lobe epilepsy garnered attention. The present study investigated the effects of epileptiform discharges (EDs) signals introduced by low-magnesium ACSF in the hippocampus of infantile male rats in vitro, using electrophysiological techniques with multi-electrode arrays under AsHC 360 exposure. In our study of the effects of AsHC 360 on EDs signals, we found that inter-ictal discharges (IIDs) were not significantly impacted. When AsHC 360 was removed, any minor effects observed were reversed. However, when we examined the impact of AsHC 360 on ictal discharges (IDs), distinct patterns emerged based on the concentration levels. For low-concentration groups (5, 20, 60 μg As L−1), both the frequency and duration effects on IDs returned to normal post-elimination of AsHC 360. However, this recovery was not evident for concentrations of 100 μg As L−1 or higher. IDs were only observed in EDs signals during exposures to AsHC 360 concentrations up to 60 μg As L−1. In these conditions, ID frequencies significantly enhanced with the increased of AsHC 360 concentration. At high concentrations of AsHC 360 (≥100 μg As L−1), the transition from IIDs or pre-ictal discharges (PIDs) to IDs was notably inhibited. Additional study on co-exposure of AsHC 360 (100 μg As L−1) and agonist (10 nM (S)-(-)-Bay-K-8644) indicated that the regulation of EDs signals under AsHC 360 exposure could be due to directly interference with the α-amino-3-hydroxy-5-methyl-4-isoxazole-propionic acid receptor (AMPAR) expression which influences the binding of excitatory glutamate neurotransmitter to AMPAR. The results suggest that EDs activities in the hippocampus of infantile Sprague Dawley rats are concentration-dependent on AsHC 360 exposure. Thus, it provides a basis for the seafood intake with AsHCs for epileptic patients and those with potential seizures.
Traditional tethered nerve implants have many limitations since they rely on physical wires for power and signal transmission. Wireless stimulation technology can promote the exploration of neurological diseases and meet patient requirements, stemming from its portability and efficiency. In this paper, the link transmission characteristics of a sub-millimeter inductor are investigated by simulation, electrical tests, and theoretical analysis. The inductor acts as the receiving coil of a wireless stimulation device, and the wireless energy transmission process based on magnetic induction coupling is analyzed. Second, a novel millimeter-scale wireless stimulator device for neuromodulation is designed based on the parameters of transmitting and receiving coils obtained from the simulation. Finally, rat electrophysiological experiments are conducted to assess the feasibility of the device. The field Excitatory Post Synaptic Potential baseline is first recorded in the CA1 radiation area for 10 min, followed by the addition of high-frequency stimulation, and after successful induction of long-term potentiation (LTP) and recording for 10 min, the two coils are fixed at a distance of 1 cm and the hippocampal Schaffer-CA1 pathway is added. The experimental results show that the addition of wireless stimulation can modulate the transmission of synaptic electrical activity in the hippocampal Schaffer-CA1 pathway and significantly increase the level of (LTP) induction. A millimeter-scale wireless stimulation device is investigated and designed in this paper, the feasibility of the device is demonstrated through ex vivo electrophysiological experiments, and its effects on the targeted modulation of the Schaffer-CA1 pathway in the rat hippocampus are described.