Richard Legras

Dr. Richard Legras

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RLRichard Legras
Richard Legras
AGAlain Gaudric
Alain Gaudric
KWKelly Woog
Kelly Woog
The aim of this article is to analyse cone density, spacing and arrangement using an adaptive optics flood illumination retina camera (rtx1™) on a healthy population. Cone density, cone spacing and packing arrangements were measured on the right retinas of 109 subjects at 2°, 3°, 4°, 5° and 6° of eccentricity along 4 meridians. The effects of eccentricity, meridian, axial length, spherical equivalent, gender and age were evaluated. Cone density decreased on average from 28 884 ± 3 692 cones/mm2, at 2° of eccentricity, to 15 843 ± 1 598 cones/mm2 at 6°. A strong inter-individual variation, especially at 2°, was observed. No important difference of cone density was observed between the nasal and temporal meridians or between the superior and inferior meridians. However, the horizontal and vertical meridians differed by around 14% (T-test, p<0.0001). Cone density, expressed in units of area, decreased as a function of axial length (r2 = 0.60), but remained constant (r2 = 0.05) when cone density is expressed in terms of visual angle supporting the hypothesis that the retina is stretched during the elongation of the eyeball. Gender did not modify the cone distribution. Cone density was slightly modified by age but only at 2°. The older group showed a smaller density (7%). Cone spacing increased from 6,49 ± 0,42 μm to 8,72 ± 0,45 μm respectively between 2° and 6° of eccentricity. The mosaic of the retina is mainly triangularly arranged (i.e. cells with 5 to 7 neighbors) from 2° to 6°. Around half of the cells had 6 neighbors.

1 March 2012 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
RLRichard Legras
Richard Legras
YBYohann Benard
Yohann Benard
NLNorberto Lopez-Gil
Norberto Lopez-Gil
To compare the effect of primary spherical aberration and vertical coma on depth of focus measured with 2 methods. Laboratoire Aimé Cotton, Centre National de la Recherche Scientifique, and Université Paris-Sud, Orsay, France. Evaluation of technology. The subjective depth of focus, defined as the interval of vision for which the target was still perceived acceptable, was evaluated using 2 methods. In the first method, the subject changed the defocus term by reshaping the mirror, which also corrected the subject's aberrations and induced a certain value of coma or primary spherical aberration. In the second procedure, the subject changed the displayed images, which were calculated for various defocuses and with the desired aberration using a numerical eye model. Depth of focus was measured using a 0.18 diopter (D) step in 4 nonpresbyopic subjects corrected for the entire eye aberrations with a 6.0 mm and 3.0 mm pupil and with the addition of 0.3 μm and 0.6 μm of positive primary spherical aberration or vertical coma. There was good concordance between the depth of focus measured with both methods (differences within 1/3 D, r(2) = 0.88). Image-quality metrics failed to predict the subjective depth of focus (r(2) < 0.41). These data confirm that defocus in the retinal image can be generated by optical or computational methods and that both can be used to assess the effect of higher-order aberrations on depth of focus. No author has a financial or proprietary interest in any material or method mentioned.

1 September 2004 in Optometry and Vision Science
Verified
Journal Article
Closed access
RLRichard Legras
Richard Legras
NCNicolas Chateau
Nicolas Chateau
WCW Neil Charman
W Neil Charman

1 June 2010 in Vision Research
Verified
Journal Article
Closed access
RLRichard Legras
Richard Legras
YBYohann Benard
Yohann Benard
HRHélène Rouger
Hélène Rouger

1 September 2004 in Optometry and Vision Science
Verified
Journal Article
Closed access
RLRichard Legras
Richard Legras
NCNicolas Chateau
Nicolas Chateau
WCW Neil Charman
W Neil Charman

29 January 2019 in Ophthalmic and Physiological Optics
Verified
Journal Article
Closed access
PDF file
KWKelly Woog
Kelly Woog
RLRichard Legras
Richard Legras