The aim of this article is to analyse cone density, spacing and arrangement using an adaptive optics flood illumination retina camera (rtx1™) on a healthy population. Cone density, cone spacing and packing arrangements were measured on the right retinas of 109 subjects at 2°, 3°, 4°, 5° and 6° of eccentricity along 4 meridians. The effects of eccentricity, meridian, axial length, spherical equivalent, gender and age were evaluated. Cone density decreased on average from 28 884 ± 3 692 cones/mm2, at 2° of eccentricity, to 15 843 ± 1 598 cones/mm2 at 6°. A strong inter-individual variation, especially at 2°, was observed. No important difference of cone density was observed between the nasal and temporal meridians or between the superior and inferior meridians. However, the horizontal and vertical meridians differed by around 14% (T-test, p<0.0001). Cone density, expressed in units of area, decreased as a function of axial length (r2 = 0.60), but remained constant (r2 = 0.05) when cone density is expressed in terms of visual angle supporting the hypothesis that the retina is stretched during the elongation of the eyeball. Gender did not modify the cone distribution. Cone density was slightly modified by age but only at 2°. The older group showed a smaller density (7%). Cone spacing increased from 6,49 ± 0,42 μm to 8,72 ± 0,45 μm respectively between 2° and 6° of eccentricity. The mosaic of the retina is mainly triangularly arranged (i.e. cells with 5 to 7 neighbors) from 2° to 6°. Around half of the cells had 6 neighbors.
1 March 2012 in Journal of Cataract & Refractive Surgery
To compare the effect of primary spherical aberration and vertical coma on depth of focus measured with 2 methods. Laboratoire Aimé Cotton, Centre National de la Recherche Scientifique, and Université Paris-Sud, Orsay, France. Evaluation of technology. The subjective depth of focus, defined as the interval of vision for which the target was still perceived acceptable, was evaluated using 2 methods. In the first method, the subject changed the defocus term by reshaping the mirror, which also corrected the subject's aberrations and induced a certain value of coma or primary spherical aberration. In the second procedure, the subject changed the displayed images, which were calculated for various defocuses and with the desired aberration using a numerical eye model. Depth of focus was measured using a 0.18 diopter (D) step in 4 nonpresbyopic subjects corrected for the entire eye aberrations with a 6.0 mm and 3.0 mm pupil and with the addition of 0.3 μm and 0.6 μm of positive primary spherical aberration or vertical coma. There was good concordance between the depth of focus measured with both methods (differences within 1/3 D, r(2) = 0.88). Image-quality metrics failed to predict the subjective depth of focus (r(2) < 0.41). These data confirm that defocus in the retinal image can be generated by optical or computational methods and that both can be used to assess the effect of higher-order aberrations on depth of focus. No author has a financial or proprietary interest in any material or method mentioned.