Grace Bishop

Ms. Grace Bishop


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2023 in Polymers
Verified
Journal Article
Open access
PDF file
AEAnusha Elumalai
Anusha Elumalai
YNYash Nayak
Yash Nayak
AGAravinda Ganapathy
Aravinda Ganapathy
DCDavid Chen
David Chen
Karthik TappaKarthik Tappa
Karthik Tappa
DBDavid Ballard
David Ballard
In recent years, 3D printing (3DP) has advanced traditional medical treatments. This review explores the fusion of reverse engineering and 3D printing of medical implants, with a specific focus on drug delivery applications. The potential for 3D printing technology to create patient-specific implants and intricate anatomical models is discussed, along with its ability to address challenges in medical treatment. The article summarizes the current landscape, challenges, benefits, and emerging trends of using 3D-printed formulations for medical implantation and drug delivery purposes.

14 October 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
YKYuktesh Varma Kalidindi
Yuktesh Varma Kalidindi
AGAravinda Ganapathy
Aravinda Ganapathy
YNYash Nayak
Yash Nayak
AEAnusha Elumalai
Anusha Elumalai
DCDavid Chen
David Chen
DBDavid Ballard
David Ballard
Three-dimensionally printed phantoms are increasingly used in medical imaging and research due to their cost-effectiveness and customizability, offering valuable alternatives to commercial phantoms. The purpose of this study was to assess the computed tomography (CT) attenuation characteristics of 27 resin materials from Formlabs, a 3D printing equipment and materials manufacturer. Cube phantoms (both solid and hollow constructions) produced with each resin were subjected to CT scanning under varying tube current–time products with attenuation measurements recorded in Hounsfield units (HU). The resins exhibited a wide range of attenuation values (−3.33 to 2666.27 HU), closely mimicking a range of human tissues, from fluids to dense bone structures. The resins also demonstrated consistent attenuation regardless of changes in the tube current. The CT attenuation analysis of FormLabs resins produced an archive of radiological imaging characteristics of photopolymers that can be utilized to construct more accurate tissue mimicking medical phantoms and improve the evaluation of imaging device performance.

Verified
Journal Article
Open access
PDF file
DCDavid Chen
David Chen
AGAravinda Ganapathy
Aravinda Ganapathy
YNYash Nayak
Yash Nayak
CMChristopher Mejias
Christopher Mejias
GBGrace Bishop
Grace Bishop
DBDavid Ballard
David Ballard
Together, the Camper’s and Scarpa’s fasciae form the superficial fat layer of the abdominal wall. Though they have clinical and surgical relevance, little is known about their role in body composition across diverse patient populations. This study aimed to determine the relationship between patient characteristics, including sex and body mass index, and the distribution of Camper’s and Scarpa’s fascial layers in the abdominal wall. A total of 458 patients’ abdominal CT examinations were segmented via CoreSlicer 1.0 to determine the surface area of each patient’s Camper’s, Scarpa’s, and visceral fascia layers. The reproducibility of segmentation was corroborated by an inter-rater analysis of segmented data for 20 randomly chosen patients divided between three study investigators. Pearson correlation and Student’s t-test analyses were performed to characterize the relationship between fascia distribution and demographic factors. The ratios of Camper’s fascia, both as a proportion of superficial fat (r = −0.44 and p < 0.0001) and as a proportion of total body fat (r = −0.34 and p < 0.0001), showed statistically significant negative correlations with BMI. In contrast, the ratios of Scarpa’s fascia, both as a proportion of superficial fat (r = 0.44 and p < 0.0001) and as a proportion of total body fat (r = 0.41 and p < 0.0001), exhibited statistically significant positive correlations with BMI. Between sexes, the females had a higher ratio of Scarpa’s facia to total body fat compared to the males (36.9% vs. 31% and p < 0.0001). The ICC values for the visceral fat, Scarpa fascia, and Camper fascia were 0.995, 0.991, and 0.995, respectively, which were all within the ‘almost perfect’ range (ICC = 0.81–1.00). These findings contribute novel insights by revealing that as BMI increases the proportion of Camper’s fascia decreases, while the ratio of Scarpa’s fascia increases. Such insights expand the scope of body composition studies, which typically focus solely on superficial and visceral fat ratios.

27 April 2023 in 3D Printing in Medicine
Verified
Journal Article
Open access
PDF file
DCDavid Chen
David Chen
AGAravinda Ganapathy
Aravinda Ganapathy
NANihil Abraham
Nihil Abraham
KMKaitlin M. Marquis
Kaitlin M. Marquis
GBGrace Bishop
Grace Bishop
DBDavid H. Ballard
David H. Ballard
Rationale and objectives: The purpose of this study is to summarize a survey of radiology chief residents focused on 3D printing in radiology. Materials and methods: An online survey was distributed to chief residents in North American radiology residencies by subgroups of the Association of University Radiologists. The survey included a subset of questions focused on the clinical use of 3D printing and perceptions of the role of 3D printing and radiology. Respondents were asked to define the role of 3D printing at their institution and asked about the potential role of clinical 3D printing in radiology and radiology residencies. Results: 152 individual responses from 90 programs were provided, with a 46% overall program response rate (n = 90/194 radiology residencies). Most programs had 3D printing at their institution (60%; n = 54/90 programs). Among the institutions that perform 3D printing, 33% (n = 18/54) have structured opportunities for resident contribution. Most residents (60%; n = 91/152 respondents) feel they would benefit from 3D printing exposure or educational material. 56% of residents (n = 84/151) believed clinical 3D printing should be centered in radiology departments. 22% of residents (n = 34/151) believed it would increase communication and improve relationships between radiology and surgery colleagues. A minority (5%; 7/151) believe 3D printing is too costly, time-consuming, or outside a radiologist’s scope of practice. Conclusions: A majority of surveyed chief residents in accredited radiology residencies believe they would benefit from exposure to 3D printing in residency. 3D printing education and integration would be a valuable addition to current radiology residency program curricula.

19 February 2023 in Clinical Imaging
Verified
Journal Article
Closed access
KMKaitlin M. Marquis
Kaitlin M. Marquis
MHMark J. Hoegger
Mark J. Hoegger
ASAnup S. Shetty
Anup S. Shetty
GBGrace Bishop
Grace Bishop
PBPatricia Balthazar
Patricia Balthazar
DBDavid H. Ballard
David H. Ballard

20 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AGAravinda Ganapathy
Aravinda Ganapathy
DBDavid Ballard
David Ballard
GBGrace Bishop
Grace Bishop
MHMark J. Hoegger
Mark J. Hoegger
NANihil Abraham
Nihil Abraham
HDHoracio B. D’agostino
Horacio B. D’agostino
Background: To report the evaluation of incentive spirometry (IS)-induced pressure changes in intra-abdominal drainage catheters and consider its use for maintaining catheter patency and enhancing drainage. Methods: Prospective study of patients with indwelling intra-abdominal drainage catheters for abdominal fluid collections who had their intra-abdominal pressures measured while performing incentive spirometry. Patients were instructed in the use of an incentive spirometer. Within a week after initial drainage, pressure changes with IS were evaluated three times at 1500 cc and three times at maximum inspiratory effort. Intra-abdominal pressure (IAP) was measured using a pressure monitor connected to the drainage catheter. Results: Twenty patients (men, 12; women, 8). Fluid collection locations were pelvis, Right-upper quadrant (RUQ), Left-upper quadrant (LUQ), Left-lower quadrant (LLQ), and Right-lower quadrant (RLQ). A total of 16 of 20 patients showed an elevation of IAP with IS. At 1500 cc, the pressure increased by an average of 41.24 mmH2O. At maximal inspiratory effort, the pressure increased by an average of 48.26 mmH2O. Pressure increase was greater in upper abdomen catheters. Four patients with lower abdominal and pelvic collections showed minimal pressure changes with IS. Conclusion: IS increases IAP and fluid flow through abdominal drainage catheters. Future studies are warranted to determine whether the use of IS enhances catheter performance and facilitates drainage via its effect on IAP.