Qingwei Song

Qingwei Song


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2019 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
JWJingjun Wu
Jingjun Wu
ALAilian Liu
Ailian Liu
JCJingjing Cui
Jingjing Cui
ACAnliang Chen
Anliang Chen
QSQingwei Song
Qingwei Song
LXLizhi Xie
Lizhi Xie
To evaluate the feasibility of using radiomics with precontrast magnetic resonance imaging for classifying hepatocellular carcinoma (HCC) and hepatic haemangioma (HH). This study enrolled 369 consecutive patients with 446 lesions (a total of 222 HCCs and 224 HHs). A training set was constituted by randomly selecting 80% of the samples and the remaining samples were used to test. On magnetic resonance (MR) images of HCC and HH obtained with in-phase, out-phase, T2-weighted imaging (T2WI), and diffusion-weighted imaging (DWI) sequences, we outlined the target lesions and extracted 1029 radiomics features, which were classified as first-, second-, higher-order statistics and shape features. Then, the variance threshold, select k best, and least absolute shrinkage and selection operator algorithms were explored for dimensionality reduction of the features. We used four classifiers (decision tree, random forest, K nearest neighbours, and logistic regression) to identify HCC and HH on the basis of radiomics features. Two abdominal radiologists also performed the conventional qualitative analysis for classification of HCC and HH. Diagnostic performances of radiomics and radiologists were evaluated by receiver operating characteristic (ROC) analysis. Valuable radiomics features for building a radiomics signature were extracted from in-phase (n = 22), out-phase (n = 24), T2WI (n = 34) and DWI (n = 24) sequences. In comparison, the logistic regression classifier showed better predictive ability by combining four sequences. In the training set, the area under the ROC curve (AUC) was 0.86 (sensitivity: 0.76; specificity: 0.78), and in the testing set, the AUC was 0.89 (sensitivity: 0.822; specificity: 0.714). The diagnostic performance for the optimal radiomics-based combined model was significantly higher than that for the less experienced radiologist (2-years experience) (AUC = 0.702, p < 0.05), and had no statistic difference with the experienced radiologist (10-years experience) (AUC = 0.908, p>0.05). We developed and validated a radiomics signature as an adjunct tool to distinguish HCC and HH by combining in-phase, out-phase, T2W, and DW MR images, which outperformed the less experienced radiologist (2-years experience), and was nearly equal to the experienced radiologist (10-years experience).

15 April 2021 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
JDJ. Ding
J. Ding
YDY. Duan
Y. Duan
ZZZhizheng Zhuo
Zhizheng Zhuo
YYY. Yuan
Y. Yuan
GZG. Zhang
G. Zhang
YLYaou Liu
Yaou Liu
BACKGROUND AND PURPOSE: The clinical practice of three-dimensional TOF-MRA, despite its capability in brain artery assessment, has been hampered by the relatively long scan time, while recent developments in fast imaging techniques with random undersampling has shed light on an improved balance between image quality and imaging speed. Our aim was to evaluate the effectiveness of TOF-MRA accelerated by compressed sensitivity encoding and to identify the optimal acceleration factors for routine clinical use. MATERIALS AND METHODS: One hundred subjects, enrolled at 5 centers, underwent 8 brain TOF-MRA sequences: 5 sequences using compressed sensitivity encoding with acceleration factors of 2, 4, 6, 8, and 10 (CS2, CS4, CS6, CS8, and CS10), 2 using sensitivity encoding with factors of 2 and 4 (SF2 and SF4), and 1 without acceleration as a reference sequence (RS). Five large arteries, 6 medium arteries, and 6 small arteries were evaluated quantitatively (reconstructed signal intensity, structural similarity, contrast ratio) and qualitatively (scores on arteries, artifacts, overall image quality, and diagnostic confidence for aneurysm and stenosis). Comparisons were performed among the 8 sequences. RESULTS: The quantitative measurements showed that the reconstructed signal intensities of the assessed arteries and the structural similarity consistently decreased as the compressed sensitivity encoding acceleration factor increased, and no significant difference was found for the contrast ratios in pair-wise comparisons among SF2, CS2, and CS4. Qualitative evaluations showed no significant difference in pair-wise comparisons among RS, SF2, and CS2 (P > .05). The visualization of all the assessed arteries was acceptable for CS2 and CS4, while 2 small arteries in images of CS6 were not reliably displayed, and the visualization of large arteries was acceptable in images of CS8 and CS10. CONCLUSIONS: CS4 is recommended for routine brain TOF-MRA with balanced image quality and acquisition time; CS6, for examinations when small arteries are not evaluated; and CS10, for fast visualization of large arteries.

1 August 2020 in European Journal of Radiology
Verified
Journal Article
Closed access
YLYangYing Qiu Liu
YangYing Qiu Liu
BGBing Bing Gao
Bing Bing Gao
BDBin Dong
Bin Dong
SCShesnia Salim Padikkalakandy Cheriyath
Shesnia Salim Padikkalakandy Cheriyath
QSQingwei Song
Qingwei Song
YMYanwei Miao
Yanwei Miao

1 January 2020 in Clinics
Verified
Journal Article
Open access
PDF file
XCXiaorui Cui
Xiaorui Cui
LLLan Li
Lan Li
LYLei Yu
Lei Yu
HXHuijuan Xing
Huijuan Xing
HCHong Chang
Hong Chang
CDChunbo Dong
Chunbo Dong
OBJECTIVES: Parkinson’s disease (PD) and the parkinsonian variant of multiple system atrophy (MSA-P) are distinct neurodegenerative disorders that share similar clinical features of parkinsonism. The morphological alterations of these diseases have yet to be understood. The purpose of this study was to evaluate gray matter atrophy in PD and MSA-P using regions of interest (ROI)-based measurements and voxel-based morphometry (VBM). METHODS: We studied 41 patients with PD, 20 patients with MSA-P, and 39 controls matched for age, sex, and handedness [...] OBJECTIVES: Parkinson’s disease (PD) and the parkinsonian variant of multiple system atrophy (MSA-P) are distinct neurodegenerative disorders that share similar clinical features of parkinsonism. The morphological alterations of these diseases have yet to be understood. The purpose of this study was to evaluate gray matter atrophy in PD and MSA-P using regions of interest (ROI)-based measurements and voxel-based morphometry (VBM). METHODS: We studied 41 patients with PD, 20 patients with MSA-P, and 39 controls matched for age, sex, and handedness

20 December 2024 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
SZShuo Zhang
Shuo Zhang
MZMeimeng Zhong
Meimeng Zhong
HSHanxu Shenliu
Hanxu Shenliu
NWNan Wang
Nan Wang
SHShuai Hu
Shuai Hu
QSQingwei Song
Qingwei Song
BACKGROUND AND PURPOSE: DWI is crucial for detecting infarction stroke. However, its spatial resolution is often limited, hindering accurate lesion visualization. Our aim was to evaluate the image quality and diagnostic confidence of deep learning (DL)-based super-resolution reconstruction for brain DWI of infarction stroke. MATERIALS AND METHODS: This retrospective study enrolled 114 consecutive participants who underwent brain DWI. The DWI images were reconstructed with 2 schemes: 1) DL-based super-resolution reconstruction (DWIDL); and 2) conventional compressed sensing reconstruction (DWICS). Qualitative image analysis included overall image quality, lesion conspicuity, and diagnostic confidence in infarction stroke of different lesion sizes. Quantitative image quality assessments were performed by measurements of SNR, contrast-to-noise ratio (CNR), ADC, and edge rise distance. Group comparisons were conducted by using a paired t test for normally distributed data and the Wilcoxon test for non-normally distributed data. The overall agreement between readers for qualitative ratings was assessed by using the Cohen κ coefficient. A P value less than .05 was considered statistically significant. RESULTS: A total of 114 DWI examinations constituted the study cohort. For the qualitative assessment, overall image quality, lesion conspicuity, and diagnostic confidence in infarction stroke lesions (lesion size <1.5 cm) improved by DWIDL compared with DWICS (all P < .001). For the quantitative analysis, edge rise distance of DWIDL was reduced compared with that of DWICS (P < .001), and no significant difference in SNR, CNR, and ADC values (all P > .05). CONCLUSIONS: Compared with the conventional compressed sensing reconstruction, the DL-based super-resolution reconstruction demonstrated superior image quality and was feasible for achieving higher diagnostic confidence in infarction stroke.

11 July 2024 in Frontiers in Endocrinology
Verified
Journal Article
Open access
PDF file
NWNan Wang
Nan Wang
ZJZhengshi Jin
Zhengshi Jin
FLFuning Liu
Funing Liu
LCLihua Chen
Lihua Chen
YZYing Zhao
Ying Zhao
QSQingwei Song
Qingwei Song
Purpose: To explore the consistency of FRACTURE (Fast-field-echo Resembling A CT Using Restricted Echo-spacing) MRI and X-Ray/computerized tomography (CT) in the evaluation of bone injuries in knee and ankle joints.Methods: From Nov. 2020 to Jul. 2023, 42 patients with knee joint or ankle joint injuries who underwent FRACTURE MRI examinations were retrospectively collected. 11 patients were examined by both X-Ray and FRACTURE examinations. 31 patients were examined by both CT and FRACTURE examinations. The fracture, osteophyte, and bone destruction of the joints were evaluated by two radiologists using X-Ray/CT and FRACTURE images, respectively. Kappa test was used for consistency analysis.Results: The evaluation consistency of fracture, osteophyte and bone destruction via X-Ray and FRACTURE images by radiologist 1 were 0.879, 0.867 and 0.847 respectively, and for radiologist 2 were 0.899, 0.930, and 0.879, respectively. The evaluation consistency of fracture, osteophyte and bone destruction via CT and FRACTURE images by radiologist 1 were 0.938, 0.937 and 0.868 respectively, and for radiologist 2 were 0.961, 0.930, and 0.818, respectively.Conclusion: For fracture, osteophyte, and bone destruction of knee and ankle joints. FRACTURE MRI showed a high consistency with X-Ray/CT examinations.