Pregnancy induces substantial anatomical, hormonal, and biomechanical changes in the spine and pelvis to accommodate fetal growth and maintain postural adaptation. This narrative review synthesizes peer-reviewed evidence regarding pregnancy-related spinal biomechanics, with a particular focus on low back pain, spinopelvic alignment, sacroiliac joint dysfunction, and potential contributions to degenerative spinal conditions. A systematic search of PubMed, Embase, and Google Scholar was conducted using Boolean operators and relevant terms, yielding 1050 unique records, with 53 peer-reviewed articles ultimately cited. The review reveals that increased lumbar lordosis, ligamentous laxity, altered gait mechanics, and muscular deconditioning elevate mechanical load on the lumbar spine, predisposing up to 56% of pregnant individuals to low back pain. These changes are often associated with sacroiliac joint laxity, anterior pelvic tilt, and multiparity. Long-term risks may include degenerative disc disease and spondylolisthesis. Conservative interventions such as pelvic floor muscle training, prenatal exercise, and surface topography monitoring offer symptom relief and support early rehabilitation, although standardized protocols and longitudinal outcome data remain limited. Pregnancy-related spinal changes are multifactorial and clinically relevant; an interdisciplinary approach involving spinal biomechanics, physical therapy, and obstetric care is critical for optimizing maternal musculoskeletal health.
Background: Pilot hole preparation has been shown to have an impact on the short and long‐term stability of the screw fixation constructs.Purpose: Investigation and comparison of two nondestructive modal analysis methods with conventional insertion torque (IT) and pullout tests in optimum pilot hole diameter detection.Methods: Twenty conical core titanium screws were embedded in high‐density polyethylene blocks with different pilot hole diameters. The maximum IT was recorded for each screw during implantation. Then, two modal analysis methods including accelerometer (classical modal analysis [CMA]) and acoustic modal analysis (AMA) were carried out to measure the natural frequency (NF) of the bone‐screw structure. Finally, stiffness (S), pullout force (Fult), displacement at Fult (dult) and energy dissipation (ED) were obtained from the destructive pullout test.Results: The IT increased, as the pilot hole diameter decreased. The maximum value of IT was observed in the smallest pilot hole diameter. The same trend was found for the Fult and the first NF derived from both modal methods except for 5.5 mm pilot hole diameter. The natural NFs derived from CMA and AMA showed high correlations in different groups (R2 = 0.94) and did not deviate from y = x hypothesis in linear regression analysis. The Fult, dult, and ED were measured 4800 ± 172 N, 3.10 ± 0.08 mm and 14.23 ± 1.10 N.mm, respectively.Discussion: No significant change was observed in “S” between the groups. The highest Fult and first NF were obtained for the 5.5 mm pilot hole diameter. Both CMA and AMA were found to be reliable methods and can promote the undesirable contradiction between Fult and IT.
BACKGROUND: Breast cancer molecular features and modern therapies are not included in spine metastasis prediction algorithms. OBJECTIVE: To examine molecular differences and the impact of postoperative systemic therapy to improve prognosis prediction for spinal metastases surgery and aid surgical decision making. METHODS: This is a retrospective multi-institutional study of patients who underwent spine surgery for symptomatic breast cancer spine metastases from 2008 to 2021 at the Massachusetts General Hospital and Brigham and Women's Hospital. We studied overall survival, stratified by breast cancer molecular subtype, and calculated hazard ratios (HRs) adjusting for demographics, tumor characteristics, treatments, and laboratory values. We tested the performance of established models (Tokuhashi, Bauer, Skeletal Oncology Research Group, New England Spinal Metastases Score) to predict and compare all-cause. RESULTS: A total of 98 patients surgically treated for breast cancer spine metastases were identified (100% female sex; median age, 56 years [IQR, 36-84 years]). The 1-year probabilities of survival for hormone receptor positive, hormone receptor positive/human epidermal growth factor receptor 2+, human epidermal growth factor receptor 2+, and triple-negative breast cancer were 63% (45 of 71), 83% (10 of 12), 0% (0 of 3), and 12% (1 of 8), respectively (P < .001). Patients with triple-negative breast cancer had a higher proportion of visceral metastases, brain metastases, and poor physical activity at baseline. Postoperative chemotherapy and endocrine therapy were associated with prolonged survival. The Skeletal Oncology Research Group prognostic model had the highest discrimination (area under the receiver operating characteristic, 0.77 [95% CI, 0.73-0.81]). The performance of all prognostic scores improved when preoperative molecular data and postoperative systemic treatment plans was considered. CONCLUSION: Spine metastases risk tools were able to predict prognosis at a significantly higher degree after accounting for molecular features which guide treatment response.
Aims: Femoroacetabular impingement (FAI) patients report exacerbation of hip pain in deep flexion. However, the exact impingement location in deep flexion is unknown. The aim was to investigate impingement-free maximal flexion, impingement location, and if cam deformity causes hip impingement in flexion in FAI patients. Methods: A retrospective study involving 24 patients (37 hips) with FAI and femoral retroversion (femoral version (FV) < 5° per Murphy method) was performed. All patients were symptomatic (mean age 28 years (SD 9)) and had anterior hip/groin pain and a positive anterior impingement test. Cam- and pincer-type subgroups were analyzed. Patients were compared to an asymptomatic control group (26 hips). All patients underwent pelvic CT scans to generate personalized CT-based 3D models and validated software for patient-specific impingement simulation (equidistant method). Results: Mean impingement-free flexion of patients with mixed-type FAI (110° (SD 8°)) and patients with pincer-type FAI (112° (SD 8°)) was significantly (p < 0.001) lower compared to the control group (125° (SD 13°)). The frequency of extra-articular subspine impingement was significantly (p < 0.001) increased in patients with pincer-type FAI (57%) compared to cam-type FAI (22%) in 125° flexion. Bony impingement in maximal flexion was located anterior-inferior at femoral four and five o’clock position in patients with cam-type FAI (63% (10 of 16 hips) and 37% (6 of 10 hips)), and did not involve the cam deformity. The cam deformity did not cause impingement in maximal flexion. Conclusion: Femoral impingement in maximal flexion was located anterior-inferior distal to the cam deformity. This differs to previous studies, a finding which could be important for FAI patients in order to avoid exacerbation of hip pain in deep flexion (e.g. during squats) and for hip arthroscopy (hip-preservation surgery) for planning of bone resection. Hip impingement in flexion has implications for daily activities (e.g. putting on shoes), sports, and sex. Cite this article: Bone Joint Res 2023;12(1):22–32.
The primary objective was to compare the subsidence resistance properties of a novel 3D-printed spinal interbody titanium implant versus a predicate polymeric annular cage. We evaluated a 3D-printed spinal interbody fusion device that employs truss-based bio-architectural features to apply the snowshoe principle of line length contact to provide efficient load distribution across the implant/endplate interface as means of resisting implant subsidence. Devices were tested mechanically using synthetic bone blocks of differing densities (osteoporotic to normal) to determine the corresponding resistance to subsidence under compressive load. Statistical analyses were performed to compare the subsidence loads and evaluate the effect of cage length on subsidence resistance. The truss implant demonstrated a marked rectilinear increase in resistance to subsidence associated with increase in the line length contact interface that corresponds with implant length irrespective of subsidence rate or bone density. In blocks simulating osteoporotic bone, comparing the shortest with the longest length truss cage (40 vs. 60 mm), the average compressive load necessary to induce subsidence of the implant increased by 46.4% (383.2 to 561.0 N) and 49.3% (567.4 to 847.2 N) for 1 and 2 mm of subsidence, respectively. In contrast, for annular cages, there was only a modest increase in compressive load when comparing the shortest with the longest length cage at a 1 mm subsidence rate. The Snowshoe truss cages demonstrated substantially more resistance to subsidence than corresponding annular cages. Clinical studies are required to support the biomechanical findings in this work.