Shu Liu

Dr. Shu Liu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2022 in Coatings
Verified
Journal Article
Open access
PDF file
JSJunhao Sui
Junhao Sui
SLShu Liu
Shu Liu
MCMengchen Chen
Mengchen Chen
HZHao Zhang
Hao Zhang
Titanium (Ti) and titanium alloy have been widely used in orthopedics. However, the successful application of titanium implants is mainly limited due to implant-associated infections. The implant surface contributes to osseointegration, but also has the risk of accelerating the growth of bacterial colonies, and the implant surfaces infected with bacteria easily form biofilms that are resistant to antibiotics. Biofilm-related implant infections are a disastrous complication of trauma orthopedic surgery and occur when an implant is colonized by bacteria. Surface bio-functionalization has been extensively studied to better realize the inhibition of bacterial proliferation to further optimize the mechanical functions of implants. Recently, the surface bio-functionalization of titanium implants has been presented to improve osseointegration. However, there are still numerous clinical and non-clinical challenges. In this review, these aspects were highlighted to develop surface bio-functionalization strategies for enhancing the clinical application of titanium implants to eliminate implant-associated infections.

21 February 2024 in Coatings
Verified
Journal Article
Open access
PDF file
JSJunhao Sui
Junhao Sui
YHYijin Hou
Yijin Hou
MCMengchen Chen
Mengchen Chen
ZZZhong Zheng
Zhong Zheng
XMXiangyu Meng
Xiangyu Meng
HZHao Zhang
Hao Zhang
Postoperative implant infection is a severe complication in orthopedic surgery, often leading to implant failure. Current treatment strategies mainly rely on systemic antibiotic therapies, despite contributing to increasing bacterial resistance. In recent years, nanomaterials have gained attention for their potential in anti-infection methods. They exhibit more substantial bactericidal effects and lower drug resistance than conventional antimicrobial agents. Nanomaterials also possess multiple bactericidal mechanisms, such as physico-mechanical interactions. Additionally, they can serve as carriers for localized antimicrobial delivery. This review explores recent applications of nanomaterials with different morphologies in post-orthopedic surgery infections and categorizes their bactericidal mechanisms.

15 June 2024 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Open access
ZXZihao Xu
Zihao Xu
LMLicai Miao
Licai Miao
XMXiangyu Meng
Xiangyu Meng
JSJunhao Sui
Junhao Sui
MCMengchen Chen
Mengchen Chen
HZHao Zhang
Hao Zhang
In the field of orthopedics, surgeons have long been facing the challenge of loosening of external fixation screws due to inherent material characteristics. Despite Polyetheretherketone (PEEK) being employed as an orthopedic implant material for many years, its bio-inert nature often hinders bone healing due to the limited bioactivity, which restricts its clinical applications. Herein, a new type of orthopedic implant (Sr-SPK) was developed by introducing strontium (Sr)-doped mesoporous bioactive glass (Sr-MBG) onto the surface of PEEK implants through a simple and feasible method. In vitro experiments revealed that Sr-SPK effectively promotes osteogenic differentiation while concurrently suppressing the formation of osteoclasts. The same results were validated in vivo with Sr-SPK significantly improving bone integration. Upon investigation, it was found that Sr-SPK promotes adhesion among bone marrow mesenchymal stem cells (BMSCs) thereby promoting osteogenesis by activating the regulation of actin cytoskeletal and focal adhesion pathways, as identified via transcriptome analysis. In essence, these findings suggest that the newly constructed Sr-doped biofunctionalized PEEK implant developed in this research can promote osteoblast differentiation and suppress osteoclast activity by enhancing cell adhesion processes. These results underline the immense potential of such an implant for wide-ranging clinical applications in orthopedics.

24 May 2023 in Coatings
Verified
Journal Article
Open access
PDF file
SLShu Liu
Shu Liu
JSJunhao Sui
Junhao Sui
KCKai Chen
Kai Chen
YDYun Ding
Yun Ding
XCXinyu Chang
Xinyu Chang
ZSZhicai Shi
Zhicai Shi
Currently, spinal interbody cages are crucial for spinal fusion surgeries. Due to the mechanical and imaging characteristics of polyetheretherketone (PEEK), it is a widely used material for cages. However, the bioinert PEEK has poor osseointegration, thereby preventing the ideal fusion of PEEK cages. Therefore, efforts have been made for improving biological activity using surface modification techniques, including physical as well as chemical modifications and surface coating. In this study, we reviewed and analyzed recent studies on PEEK surface modification techniques to enhance our understanding for future studies.

16 October 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
ZHZebin Huang
Zebin Huang
SLShu Liu
Shu Liu
MNMaodan Nie
Maodan Nie
JYJiabin Yuan
Jiabin Yuan
XLXumiao Lin
Xumiao Lin
ZSZhicai Shi
Zhicai Shi
A novel interlaminar elastic screw spacer technique was designed to maintain lumbar mobility in treating lumbar degenerative diseases. A validated finite element model of L4/5 was used to establish an ISES-1/2 model and an ISES-1/3 model based on different insertion points, a unilateral fixation model and a bilateral fixed model based on different fixation methods, and a Coflex-F model based on different implants. The elastic rods were used to fix screws. Under the same mechanical conditions, we compared the biomechanical characteristics to investigate the optimal entry point for ISES technology, demonstrate the effectiveness of unilateral fixation, and validate the feasibility of the ISES technique. Compared to ISES-1/3, the ISES-1/2 model had lower intradiscal pressure, facet cartilage stress, and posterior structural stress. Compared to the ISES-BF model, the ISES-UF model had lower intervertebral pressure, larger mobility, and smaller stress on the posterior structures. The ISES model had a similar intervertebral pressure and limitation of extension as the Coflex-F model. The ISES model retained greater mobility and reduced the stress on the facet cartilage and posterior structure compared with the Coflex-F model. Our study suggests that the ISES technique is a promising treatment of lumbar degenerative diseases, especially those with osteoporosis.