The ability to obtain quantitative values of flow and myocardial flow reserve (MFR) has been perceived as an important advantage of PET over conventional nuclear myocardial perfusion imaging (MPI). We evaluated the added diagnostic value of MFR over MPI alone as assessed with (13)N-ammonia and PET/CT to predict angiographic coronary artery disease (CAD). Seventy-three patients underwent 1-d adenosine stress-rest (13)N-ammonia PET/CT MPI, and MFR was calculated. The added value of MFR as an adjunct to MPI for predicting CAD (luminal narrowing ≥ 50%) was evaluated using invasive coronary angiography as a standard of reference. Per patient, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of MPI for detecting significant CAD were 79%, 80%, 91%, 59%, and 79%, respectively. Adding a cutoff of less than 2.0 for global MFR to MPI findings improved the values to 96% (P < 0.005), 80%, 93%, 89% (P < 0.005), and 92% (P < 0.005), respectively. The quantification of MFR in (13)N-ammonia PET/CT MPI provides a substantial added diagnostic value for detection of CAD. Particularly in patients with normal MPI results, quantification of MFR helps to unmask clinically significant CAD.
We aimed at establishing the optimal scan time for nuclear myocardial perfusion imaging (MPI) on an ultrafast cardiac γ-camera using a novel cadmium-zinc-telluride (CZT) solid-state detector technology. Methods: Twenty patients (17 male; BMI range, 21.7–35.5 kg/m2) underwent 1-d 99mTc-tetrofosmin adenosine stress and rest MPI protocols, each with a 15-min acquisition on a standard dual-detector SPECT camera. All scans were immediately repeated on an ultrafast CZT camera over a 6-min acquisition time and reconstructed from list-mode raw data to obtain scan durations of 1 min, 2 min, etc., up to a maximum of 6 min. For each of the scan durations, the segmental tracer uptake value (percentage of maximum myocardial uptake) from the CZT camera was compared by intraclass correlation with standard SPECT camera data using a 20-segment model, and clinical agreement was assessed per coronary territory. Scan durations above which no further relevant improvement in uptake correlation was found were defined as minimal required scan times, for which Bland–Altman limits of agreement were calculated. Results: Minimal required scan times were 3 min for low dose (r = 0.81; P < 0.001; Bland–Altman, −11.4% to 12.2%) and 2 min for high dose (r = 0.80; P < 0.001; Bland–Altman, −7.6% to 12.9%), yielding a clinical agreement of 95% and 97%, respectively. Conclusion: We have established the minimal scan time for a CZT solid-state detector system, which allows 1-d stress/rest MPI with a substantially reduced acquisition time resulting in excellent agreement with regard to uptake and clinical findings, compared with MPI from a standard dual-head SPECT γ-camera.
27 January 2010 in European Journal of Nuclear Medicine and Molecular Imaging
The purpose of this study was to assess the relationship between calcium scoring (CS) and multi-slice computed tomography coronary angiography (MSCTA) and to determine if MSCTA has an incremental prognostic value to CS. In 432 patients (59% male, age 58 ± 11 years) referred for cardiac evaluation owing to suspected coronary artery disease (CAD), CS and 64-slice MSCTA were performed. The following events were combined in a composite endpoint: all-cause mortality, non-fatal infarction, and unstable angina requiring revascularization. CS was 0 in 147 (34%) patients, CS 1–99 was present in 122 (28%), CS 100–399 in 75 (17%), CS 400–999 in 56 (13%), and CS ≥ 1000 in 32 (7%). MSCTA was normal in 133 (31%) patients, MSCTA 30–50% stenosis was observed in 190 (44%), and MSCTA ≥50% stenosis in 109 (25%). During follow-up [median 670 days (25th–75th percentile: 418–895)], an event occurred in 21 patients (4.9%). After multivariate correction for CS, MSCTA ≥ 50% stenosis, the number of diseased segments, obstructive segments, and non-calcified plaques were independent predictors with an incremental prognostic value to CS. MSCTA provides additional information to CS regarding stenosis severity and plaque composition. This additional information was shown to translate into incremental prognostic value over CS.
Recent advances in SPECT technology including cadmium–zinc–telluride (CZT) semiconductor detector material may pave the way for absolute myocardial blood flow (MBF) measurements by SPECT. The aim of the present study was to compare K1 uptake rate constants as surrogates of absolute MBF and myocardial flow reserve index (MFRi) in humans as assessed with a CZT SPECT camera versus PET. Methods: Absolute MBF was assessed in 28 consecutive patients undergoing adenosine stress–rest myocardial perfusion imaging (MPI) by 99mTc-tetrofosmin CZT SPECT and 13N-ammonia PET, and MFR was calculated as a ratio of hyperemic over resting MBF. Results from both MPI methods were compared, and correlation coefficients were calculated. The diagnostic accuracy of CZT MFRi to predict an abnormal MFR defined as PET MFR less than 2 was assessed using a receiver-operator-characteristic curve. Results: Median MBF at rest was comparable between CZT and PET (0.89 [interquartile range (IQR), 0.77–1.00] vs. 0.92 [IQR, 0.78–1.06] mL/g/min; P = not significant) whereas it was significantly lower at stress in CZT than PET (1.11 [IQR, 1.00–1.26] vs. 2.06 [IQR, 1.48–2.56] mL/g/min; P < 0.001). This resulted in median MFRi values of 1.32 (IQR, 1.13–1.52) by CZT and 2.36 (IQR, 1.57–2.71) by PET (P < 0.001). The receiver-operator-characteristic curve revealed a cutoff for CZT MFRi at 1.26 to predict an abnormal PET MFR yielding an accuracy of 75%. Conclusion: The estimation of absolute MBF index values by CZT SPECT MPI with 99mTc-tetrofosmin is technically feasible, although hyperemic values are significantly lower than from PET with 13N-ammonia, resulting in a substantial underestimation of MFR. Nevertheless, CZT MFRi may confer diagnostic value.