Jeroen Bax

Prof. Dr. Jeroen Bax


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
ANArnold C.T. Ng
Arnold C.T. Ng
VDVictoria Delgado
Victoria Delgado
FKFrank van der Kley
Frank van der Kley
MSMiriam Shanks
Miriam Shanks
NVNico R.L. van de Veire
Nico R.L. van de Veire
JBJeroen Bax
Jeroen Bax
Background— 3D transesophageal echocardiography (TEE) may provide more accurate aortic annular and left ventricular outflow tract (LVOT) dimensions and geometries compared with 2D TEE. We assessed agreements between 2D and 3D TEE measurements with multislice computed tomography (MSCT) and changes in annular/LVOT areas and geometries after transcatheter aortic valve implantations (TAVI).

13 November 2020 in Nature Reviews Cardiology
Verified
Journal Article
Closed access
PDF file
ANArnold C. T. Ng
Arnold C. T. Ng
VDVictoria Delgado
Victoria Delgado
BBBarry A. Borlaug
Barry A. Borlaug
JBJeroen Bax
Jeroen Bax

1 February 2009 in JACC
Verified
Journal Article
Closed access
JWJacob M. van Werkhoven
Jacob M. van Werkhoven
JSJoanne D. Schuijf
Joanne D. Schuijf
OGOliver Gaemperli
Oliver Gaemperli
JJJ. Wouter Jukema
J. Wouter Jukema
EBEric Boersma
Eric Boersma
JBJeroen Bax
Jeroen Bax

1 March 2019 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
EPEdgard A. Prihadi
Edgard A. Prihadi
VDVictoria Delgado
Victoria Delgado
MLMartin B. Leon
Martin B. Leon
MEMaurice Enriquez-Sarano
Maurice Enriquez-Sarano
YTYan Topilsky
Yan Topilsky
JBJeroen Bax
Jeroen Bax

12 September 2019 in European Heart Journal
Verified
Journal Article
Closed access
PDF file
SASubhi J. AlAref
Subhi J. AlAref
GMGabriel Maliakal
Gabriel Maliakal
GSGurpreet Singh
Gurpreet Singh
ARAlexander R van Rosendael
Alexander R van Rosendael
XMXiaoyue Ma
Xiaoyue Ma
LSLeslee J Shaw
Leslee J Shaw
Symptom-based pretest probability scores that estimate the likelihood of obstructive coronary artery disease (CAD) in stable chest pain have moderate accuracy. We sought to develop a machine learning (ML) model, utilizing clinical factors and the coronary artery calcium score (CACS), to predict the presence of obstructive CAD on coronary computed tomography angiography (CCTA). The study screened 35 281 participants enrolled in the CONFIRM registry, who underwent ≥64 detector row CCTA evaluation because of either suspected or previously established CAD. A boosted ensemble algorithm (XGBoost) was used, with data split into a training set (80%) on which 10-fold cross-validation was done and a test set (20%). Performance was assessed of the (1) ML model (using 25 clinical and demographic features), (2) ML + CACS, (3) CAD consortium clinical score, (4) CAD consortium clinical score + CACS, and (5) updated Diamond-Forrester (UDF) score. The study population comprised of 13 054 patients, of whom 2380 (18.2%) had obstructive CAD (≥50% stenosis). Machine learning with CACS produced the best performance [area under the curve (AUC) of 0.881] compared with ML alone (AUC of 0.773), CAD consortium clinical score (AUC of 0.734), and with CACS (AUC of 0.866) and UDF (AUC of 0.682), P < 0.05 for all comparisons. CACS, age, and gender were the highest ranking features. A ML model incorporating clinical features in addition to CACS can accurately estimate the pretest likelihood of obstructive CAD on CCTA. In clinical practice, the utilization of such an approach could improve risk stratification and help guide downstream management.

23 April 2019 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
PPPhilippe Pibarot
Philippe Pibarot
VDVictoria Delgado
Victoria Delgado
JBJeroen Bax
Jeroen Bax
Percutaneous mitral valve repair using the MitraClip device has been proposed to correct secondary mitral regurgitation (MR). Recently, the results of two randomized controlled trials, that is MITRA-FR (Percutaneous Repair with the MitraClip Device for Severe Functional/Secondary Mitral Regurgitation) and COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation), assessing the efficacy and safety of MitraClip in patients with systolic heart failure and severe secondary MR were published. A priori, these two trials targeted the same patient populations with the same disease using the same device but the results of these trials were diametrically opposed, MITRA-FR being neutral and COAPT being highly positive with respect to efficacy of the MitraClip procedure. The objectives of this viewpoint are: (i) to highlight not only the similarities but also the differences between MITRA-FR and COAPT, which may explain the strikingly different results and conclusions between these two trials and (ii) to derive from these results, implications with regards to the application of the MitraClip procedure in clinical practice.