Emiel DenHartog

Dr. Emiel DenHartog

orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2013 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
GHGeorge Havenith
George Havenith
PBPeter Bröde
Peter Bröde
EDEmiel DenHartog
Emiel DenHartog
Kalev KuklaneKalev Kuklane
Kalev Kuklane
IHIngvar Holmer
Ingvar Holmer
XWXiaoxin Wang
Xiaoxin Wang
Calculation of evaporative heat loss is essential to heat balance calculations. Despite recognition that the value for latent heat of evaporation, used in these calculations, may not always reflect the real cooling benefit to the body, only limited quantitative data on this is available, which has found little use in recent literature. In this experiment a thermal manikin, (MTNW, Seattle, WA) was used to determine the effective cooling power of moisture evaporation. The manikin measures both heat loss and mass loss independently, allowing a direct calculation of an effective latent heat of evaporation (λeff). The location of the evaporation was varied: from the skin or from the underwear or from the outerwear. Outerwear of different permeabilities was used, and different numbers of layers were used. Tests took place in 20°C, 0.5 m/s at different humidities and were performed both dry and with a wet layer, allowing the breakdown of heat loss in dry and evaporative components. For evaporation from the skin, λeff is close to the theoretical value (2,430 J/g) but starts to drop when more clothing is worn, e.g., by 11% for underwear and permeable coverall. When evaporation is from the underwear, λeff reduction is 28% wearing a permeable outer. When evaporation is from the outermost layer only, the reduction exceeds 62% (no base layer), increasing toward 80% with more layers between skin and wet outerwear. In semi- and impermeable outerwear, the added effect of condensation in the clothing opposes this effect. A general formula for the calculation of λeff was developed.

1 January 2008 in Journal of Applied Physiology
Verified
Journal Article
Closed access
GHGeorge Havenith
George Havenith
MRMark G. Richards
Mark G. Richards
XWXiaoxin Wang
Xiaoxin Wang
PBPeter Bröde
Peter Bröde
VCVictor Candas
Victor Candas
WNWolfgang Nocker
Wolfgang Nocker
Investigating claims that a clothed person's mass loss does not always represent their evaporative heat loss (EVAP), a thermal manikin study was performed measuring heat balance components in more detail than human studies would permit. Using clothing with different levels of vapor permeability and measuring heat losses from skin controlled at 34°C in ambient temperatures of 10, 20, and 34°C with constant vapor pressure (1 kPa), additional heat losses from wet skin compared with dry skin were analyzed. EVAP based on mass loss ( Emass) measurement and direct measurement of the extra heat loss by the manikin due to wet skin ( Eapp) were compared. A clear discrepancy was observed. Emass overestimated Eapp in warm environments, and both under and overestimations were observed in cool environments, depending on the clothing vapor permeability. At 34°C, apparent latent heat (λapp) of pure evaporative cooling was lower than the physical value (λ; 2,430 J/g) and reduced with increasing vapor resistance up to 45%. At lower temperatures, λapp increases due to additional skin heat loss via evaporation of moisture that condenses inside the clothing, analogous to a heat pipe. For impermeable clothing, λapp even exceeds λ by four times that value at 10°C. These findings demonstrate that the traditional way of calculating evaporative heat loss of a clothed person can lead to substantial errors, especially for clothing with low permeability, which can be positive or negative, depending on the climate and clothing type. The model presented explains human subject data on EVAP that previously seemed contradictive.

4 May 2011 in Ergonomics
Verified
Journal Article
Closed access
GHGeorge Havenith
George Havenith
EDEmiel DenHartog
Emiel DenHartog
SMSvein Martini
Svein Martini
Heat strain in chemical protective clothing is an important factor in industrial and military practice. Various improvements to the clothing to alleviate strain while maintaining protection have been attempted. More recently, selectively permeable membranes have been introduced to improve protection, but questions are raised regarding their effect on heat strain. In this paper the use of selectively permeable membranes with low vapour resistance was compared to textile-based outer layers with similar ensemble vapour resistance. For textile-based outer layers, the effect of increasing air permeability was investigated. When comparing ensembles with a textile vs. a membrane outer layer that have similar heat and vapour resistances measured for the sum of fabric samples, a higher heat strain is observed in the membrane ensemble, as in actual wear, and the air permeability of the textile version improves ventilation and allows better cooling by sweat evaporation. For garments with identical thickness and static dry heat resistance, but differing levels of air permeability, a strong correlation of microclimate ventilation due to wind and movement with air permeability was observed. This was reflected in lower values of core and skin temperatures and heart rate for garments with higher air permeability. For heart rate and core temperature the two lowest and the two highest air permeabilities formed two distinct groups, but they did not differ within these groups. Based on protection requirements, it is concluded that air permeability increases can reduce heat strain levels allowing optimisation of chemical protective clothing. Statement of Relevance: In this study on chemical, biological, radiological and nuclear (CBRN) protective clothing, heat strain is shown to be significantly higher with selectively permeable membranes compared to air permeable ensembles. Optimisation of CBRN personal protective equipment needs to balance sufficient protection with reduced heat strain. Using selectively permeable membranes may optimise protection but requires thorough consideration of the wearer's heat strain.

1 January 2006 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
JKJ. A. Kistemaker
J. A. Kistemaker
EDEmiel DenHartog
Emiel DenHartog
HDHein A.M. Daanen
Hein A.M. Daanen
The SensorTouch thermometer performs an infrared measurement of the skin temperature above the Superficial Temporal Artery (STA). This study evaluates the validity and the accuracy of the SensorTouch thermometer. Two experiments were performed in which the body temperature was measured with a rectal sensor, with an oesophageal sensor and with the SensorTouch. After entering a warm chamber the SensorTouch underestimated the core temperature during the first 10 minutes. After that, the SensorTouch was not significantly different from the core temperature, with an average difference of 0.5 degrees C (SD 0.5 degrees C) in the first study and 0.3 degrees C (SD 0.2 degrees C) in the second study. The largest differences between the SensorTouch and the core temperature existed 15 minutes after the start of the exercise. During this period the SensorTouch was significantly higher than the core temperature. The SensorTouch did not provide reliable values of the body temperature during periods of increasing body temperature, but the SensorTouch might work under stable conditions.

1 April 1993 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
WUWim Uijttewaal
Wim Uijttewaal
ENE. J. Nijhof
E. J. Nijhof
PBP. J. Bronkhorst
P. J. Bronkhorst
EDEmiel DenHartog
Emiel DenHartog
RHR. M. Heethaar
R. M. Heethaar
In this study we present experimental data on the inhomogeneous distribution of platelets in polyethylene tubes (200 microns diam) based on the inverse Fahraeus effect for platelets. It is shown that platelets are expelled toward the red blood cell-depleted marginal layer near the tube wall by mutual interaction with erythrocytes. By means of a straightforward model, the near-wall concentration of platelets could be estimated from measurements on the average tubular platelet concentration. The marginal layer originates from the hydrodynamic interaction of the deformable erythrocytes with the tube wall. If the tube diameter is large compared with the size of the erythrocytes, the lateral migration effects can effectively be scaled on the absolute distance between the erythrocytes and the tube wall. This results in the main conclusion that the near-wall concentration of platelets is significantly enhanced up to about seven times the average concentration, practically irrespective of the tube diameter in the range of 100-500 microns. Where comparable, the results of this study are in accordance with experimental data of other authors.

1 July 2018 in Applied Ergonomics
Verified
Journal Article
Closed access
MMMeredith McQuerry
Meredith McQuerry
RBRoger Barker
Roger Barker
EDEmiel DenHartog
Emiel DenHartog