This systematic review assessed the literature to evaluate the efficiency of polymerization of bulk-fill composite resins at 4 mm restoration depth. PubMed, Cochrane, Scopus and Web of Science databases were searched with no restrictions on year, publication status, or article’s language. Selection criteria included studies that evaluated bulk-fill composite resin when inserted in a minimum thickness of 4 mm, followed by curing according to the manufacturers’ instructions; presented sound statistical data; and comparison with a control group and/or a reference measurement of quality of polymerization. The evidence level was evaluated by qualitative scoring system and classified as high-, moderate- and low- evidence level. A total of 534 articles were retrieved in the initial search. After the review process, only 10 full-text articles met the inclusion criteria. Most articles included (80%) were classified as high evidence level. Among several techniques, microhardness was the most frequently method performed by the studies included in this systematic review. Irrespective to the “in vitro” method performed, bulk fill RBCs were partially likely to fulfill the important requirement regarding properly curing in 4 mm of cavity depth measured by depth of cure and / or degree of conversion. In general, low viscosities BFCs performed better regarding polymerization efficiency compared to the high viscosities BFCs.
Objective: Direct laser metal forming (DLMF) is a procedure in which a high‐power laser beam is directed onto a metal powder bed and programmed to fuse particles according to a computer‐aided design file, generating a thin metal layer. This histologic study evaluated the bone‐to‐implant contact (BIC%) around immediately loaded DLMF transitional implants retrieved after 2 months from posterior human maxillae.Methods: Twelve totally edentulous individuals (mean age, 66.14 ± 2.11 years) received DLMF transitional implants divided in twelve immediately loaded (IL) and twelve unloaded (UI) implants. These transitional implants were placed between conventional implants to support the interim complete maxillary denture during the healing period. After 8 weeks, the transitional implants and the surrounding tissue were removed and prepared for histomorphometric analysis.Results: Mature woven preexisting bone lined by newly formed bone in early stages of maturation were found around all retrieved implants. Histometric evaluation indicated that the mean BIC% was 45.20 ± 7.68% and 34.10 ± 7.85% for IL and UI, respectively (P <0.05).Conclusion: The present data obtained in humans showed that, although both IL and UI presented good BIC%, IL DLMF implants had a higher BIC% in the posterior maxilla.
The establishment of the subgingival microbiota is dependent on successive colonization of the implant surface by bacterial species. Different implant surface topographies could influence the bacterial adsorption and therefore jeopardize the implant survival. This study evaluated the biofilm formation capacity of five oral streptococci species on two titanium surface topographies.In vitrobiofilm formation was induced on 30 titanium discs divided in two groups: sandblasted acid-etched (SAE-) and as-machined (M-) surface. The specimens were immersed in sterilized whole human unstimulated saliva and then in fresh bacterial culture with five oral streptococci species:Streptococcus sanguinis,Streptococcus salivarius,Streptococcus mutans,Streptococcus sobrinus, andStreptococcus cricetus. The specimens were fixed and stained and the adsorbed dye was measured. Surface characterization was performed by atomic force and scanning electron microscopy. Surface and microbiologic data were analyzed by Student’s-test and two-way ANOVA, respectively ().S. cricetus,S. mutans,andS. sobrinusexhibited higher biofilm formation and no differences were observed between surfaces analyzed within each species ().S. sanguinisexhibited similar behavior to form biofilm on both implant surface topographies, whileS. salivariusshowed the lowest ability to form biofilm. It was concluded that biofilm formation on titanium surfaces depends on surface topography and species involved.
SUMMARY: Objectives: This study evaluated the degree of conversion (DC) and working time (WT) of two commercial, dual-cured resin cements polymerized at varying temperatures and under different curing-light accessible conditions, using Fourier transformed infrared analysis (FTIR). Materials and Methods: Calibra (Cal; Dentsply Caulk) and Variolink II (Ivoclar Vivadent) were tested at 25°C or preheated to 37°C or 50°C and applied to a similar-temperature surface of a horizontal attenuated-total-reflectance unit (ATR) attached to an infrared spectrometer. The products were polymerized using one of four conditions: direct light exposure only (600 mW/cm2) through a glass slide or through a 1.5- or 3.0-mm-thick ceramic disc (A2 shade, IPS e.max, Ivoclar Vivadent) or allowed to self-cure in the absence of light curing. FTIR spectra were recorded for 20 min (1 spectrum/s, 16 scans/spectrum, resolution 4 cm−1) immediately after application to the ATR. DC was calculated using standard techniques of observing changes in aliphatic-to-aromatic peak ratios precuring and 20-min postcuring as well as during each 1-second interval. Time-based monomer conversion analysis was used to determine WT at each temperature. DC and WT data (n=6) were analyzed by two-way analysis of variance and Tukey post hoc test (p=0.05). Results: Higher temperatures increased DC regardless of curing mode and product. For Calibra, only the 3-mm-thick ceramic group showed lower DC than the other groups at 25°C (p=0.01830), while no significant difference was observed among groups at 37°C and 50°C. For Variolink, the 3-mm-thick ceramic group showed lower DC than the 1-mm-thick group only at 25°C, while the self-cure group showed lower DC than the others at all temperatures (p=0.00001). WT decreased with increasing temperature: at 37°C near 70% reduction and at 50°C near 90% for both products, with WT reduction reaching clinically inappropriate times in some cases (p=0.00001). Conclusion: Elevated temperature during polymerization of dual-cured cements increased DC. WT was reduced with elevated temperature, but the extent of reduction might not be clinically acceptable.