Wen-Chih Liu

Dr. Wen-Chih Liu

Kaohsiung Medical University Chung-Ho Memorial Hospital, Kaohsiung City, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

27 July 2024 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
FRFloris V. Raasveld
Floris V. Raasveld
MMMaximilian Mayrhofer-Schmid
Maximilian Mayrhofer-Schmid
BJBenjamin R. Johnston
Benjamin R. Johnston
BGBarbara Gomez-Eslava
Barbara Gomez-Eslava
YHYannick A.J. Hoftiezer
Yannick A.J. Hoftiezer
KEKyle R. Eberlin
Kyle R. Eberlin

16 September 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CLChun-Kuan Lu
Chun-Kuan Lu
WLWen-Chih Liu
Wen-Chih Liu
CCChung-Chia Chang
Chung-Chia Chang
CSChia-Lung Shih
Chia-Lung Shih
YFYin-Chih Fu
Yin-Chih Fu
JJJesse B. Jupiter
Jesse B. Jupiter
Background: Distal radius fracture (DRF) is the most common upper extremity fracture that requires surgery. Operative treatment with a volar locking plate has proved to be the treatment of choice for unstable fractures. However, no consensus has been reached about the benefits of pronator quadratus (PQ) repair after volar plate fixation of DRF in terms of patient-reported outcome measures, pronation strength, and wrist mobility. Methods: We searched the PubMed, Embase, Cochrane Central, and China National Knowledge Infrastructure (CNKI) databases up to March 13, 2020, and included randomized-controlled, non-randomized controlled, or case-control cohort studies that compared cases with and without PQ repair after volar plate fixation of DRF. We used a random-effects model to pool effect sizes, which were expressed as standardized mean differences (SMDs) and 95% confidence intervals. The primary outcomes included Disabilities of the Arm, Shoulder, and Hand scores and pronation strength. The secondary outcomes included the SMDs in pain scale score, wrist mobility, and grip strength. The outcomes measured were assessed for publication bias by using a funnel plot and the Egger regression test. Results: Five randomized controlled studies and six retrospective case-control studies were included in the meta-analysis. We found no significant difference in primary and secondary outcomes at a minimum of 6-month follow-up. In a subgroup analysis, the pronation strength in the PQ repair group for AO type B DRFs (SMD = − 0.94; 95% CI, − 1.54 to − 0.34; p < 0.01) favored PQ repair, whereas that in the PQ repair group for non-AO type B DRFs (SMD = 0.39; 95% CI, 0.07–0.70; p = 0.02) favored no PQ repair. Discussion: We found no functional benefit of PQ repair after volar plate fixation of DRF on the basis of the present evidence. However, PQ muscle repair showed different effects on pronation strength in different groups of DRFs. Future studies are needed to confirm the relationship between PQ repair and pronation strength among different patterns of DRF. Registration: This study was registered in the PROSPERO registry under registration ID No. CRD42020188343. Level of evidence: Therapeutic III

Verified
Journal Article
Open access
PDF file
CTChien-Cheng Tai
Chien-Cheng Tai
HLHON LOK LO
HON LOK LO
CLChen-Kun Liaw
Chen-Kun Liaw
YHYu-Min Huang
Yu-Min Huang
YHYen-Hua Huang
Yen-Hua Huang
Chih-Yu ChenChih-Yu Chen
Chih-Yu Chen
This study evaluated the biocompatibility and biological performance of novel additive-manufactured bioabsorbable iron-based porous suture anchors (iron_SAs). Two types of bioabsorbable iron_SAs, with double- and triple-helical structures (iron_SA_2_helix and iron_SA_3_helix, respectively), were compared with the synthetic polymer-based bioabsorbable suture anchor (polymer_SAs). An in vitro mechanical test, MTT assay, and scanning electron microscope (SEM) analysis were performed. An in vivo animal study was also performed. The three types of suture anchors were randomly implanted in the outer cortex of the lateral femoral condyle. The ultimate in vitro pullout strength of the iron_SA_3_helix group was significantly higher than the iron_SA_2_helix and polymer_SA groups. The MTT assay findings demonstrated no significant cytotoxicity, and the SEM analysis showed cells attachment on implant surface. The ultimate failure load of the iron_SA_3_helix group was significantly higher than that of the polymer_SA group. The micro-CT analysis indicated the iron_SA_3_helix group showed a higher bone volume fraction (BV/TV) after surgery. Moreover, both iron SAs underwent degradation with time. Iron_SAs with triple-helical threads and a porous structure demonstrated better mechanical strength and high biocompatibility after short-term implantation. The combined advantages of the mechanical superiority of the iron metal and the possibility of absorption after implantation make the iron_SA a suitable candidate for further development.

4 March 2022 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
CLChih-Yao Lee
Chih-Yao Lee
PCPo-Cheng Chen
Po-Cheng Chen
YLYing-Chun Liu
Ying-Chun Liu
YTYun-Che Tsai
Yun-Che Tsai
PCPei-Hsi Chou
Pei-Hsi Chou
JJJesse Bernard Jupiter
Jesse Bernard Jupiter
Background: Acromioclavicular joint (ACJ) dislocation is a common shoulder injury. In treating acute unstable ACJ dislocation, a hook plate (HP) is a straightforward and popular option for ensuring proper reduction and rigid fixation while promoting AC and coracoclavicular (CC) ligament healing. Surgeons typically remove the HP to prevent subacromial impingement and acromial osteolysis; however, concerns about redislocation after implant removal remain. Therefore, additional CC augmentation may be helpful in combination with HP fixation. The aim of this meta-analysis is to compare the outcomes and complications of HP fixation with or without additional CC augmentation for acute unstable ACJ dislocation. Methods: We searched the PubMed, EMBASE, and Web of Science databases for relevant case–control studies. The primary outcomes were patient-reported outcome measures; the secondary outcomes were pain measured using a visual analog scale (VAS), CC distance (CCD), and complications. Continuous data were assessed using weighted standardized mean differences (SMDs) with 95% confidence intervals (CIs), and dichotomous data were evaluated with Mantel–Haenszel odds ratio (ORs) with 95% CIs. Results: We analyzed one randomized control trial and four case–control studies comparing HP fixation with or without CC augmentation. A total of 474 patients with Rockwood type III or V ACJ dislocation were included. We found no differences in Constant–Murley score (SMD, − 0.58, 95% CI − 1.41 to 0.26; P = 0.18), American Shoulder and Elbow Surgeons score (SMD, 0.21, 95% CI − 0.10 to 0.52; P = 0.19), University of California at Los Angeles shoulder rating scale score (SMD, − 0.02, 95% CI − 1.27 to 1.23; P = 0.97), or VAS pain score (SMD, 0.36, 95% CI − 0.16 to 0.88; P = 0.17) between groups. The CC augmentation group had lower odds of osteolysis (OR, 0.27, 95% CI 0.10 to 0.74; P = 0.01) and a shorter CCD (SMD, − 0.29, 95% CI − 0.57 to − 0.01; P = 0.04). Conclusion: HP fixation with CC augmentation is preferable for acute unstable ACJ dislocations. Although CC augmentation did not provide additional benefits related to functional outcomes or pain, it resulted in greater reduction maintenance after implant removal and a 73% lower risk of acromial osteolysis. Trial registration: PROSPERO (CRD42021271118).

21 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
WLWen-Chih Liu
Wen-Chih Liu
ILI-Cheng Lu
I-Cheng Lu
CCChung-Chia Chang
Chung-Chia Chang
CCChih-Ting Chen
Chih-Ting Chen
Chung-Hwan ChenChung-Hwan Chen
Chung-Hwan Chen
JJJesse Bernard Jupiter
Jesse Bernard Jupiter
This prospective case-control study aimed to compare the intraoperative hemodynamic changes between the wide-awake local anesthesia no tourniquet (WALANT) technique and general anesthesia (GA) in patients undergoing distal radius plating surgery. Forty adults with distal radius fractures underwent plating surgery via the WALANT technique (20 patients) or GA (20 patients). Mean arterial pressure (MAP) and heart rate were recorded. Intraoperative pain intensity was measured using the visual analog scale (VAS) for pain in the WALANT group. The measures of hemodynamics and VAS were recorded at seven-time points perioperatively. The VAS score decreased significantly compared with the preoperative status in the WALANT group for most of the intraoperative period except during injections of local anesthetics and fracture reduction. The intraoperative MAP in the WALANT group showed no significant change during the perioperative period. In addition, the WALANT group showed fewer perioperative MAP fluctuations than the GA group (p < 0.05). The reduction and plating quality were similar between the two groups. WALANT provided a feasible technique with less fluctuation in hemodynamic status. With gentle manipulation of the fracture reduction, distal radius plating surgery using the WALANT technique is a well-tolerated surgical procedure and shows similar reduction and plating quality to GA.