Glioblastoma (GBM) is a common and highly malignant primary tumor of the central nervous system in adults. Ever more recent papers are focusing on understanding the role of the tumor microenvironment (TME) in affecting tumorigenesis and the subsequent prognosis. We assessed the impact of macrophages in the TME on the prognosis in patients with recurrent GBM. A PubMed, MEDLINE and Scopus review was conducted to identify all studies dealing with macrophages in the GBM microenvironment from January 2016 to December 2022. Glioma-associated macrophages (GAMs) act critically in enhancing tumor progression and can alter drug resistance, promoting resistance to radiotherapy and establishing an immunosuppressive environment. M1 macrophages are characterized by increased secretion of proinflammatory cytokines, such as IL-1ß, tumor necrosis factor (TNF), IL-27, matrix metalloproteinase (MMPs), CCL2, and VEGF (vascular endothelial growth factor), IGF1, that can lead to the destruction of the tissue. In contrast, M2 is supposed to participate in immunosuppression and tumor progression, which is formed after being exposed to the macrophage M-CSF, IL-10, IL-35 and the transforming growth factor-ß (TGF-β). Because there is currently no standard of care in recurrent GBM, novel identified targeted therapies based on the complex signaling and interactions between the glioma stem cells (GSCs) and the TME, especially resident microglia and bone-marrow-derived macrophages, may be helpful in improving the overall survival of these patients in the near future.
Background: Simulation-based techniques using three-dimensional models are gaining popularity in neurosurgical training. Most pre-existing models are expensive, so we felt a need to develop a real-life model using 3D printing technology to train in endoscopic third ventriculostomy. Methods: The brain model was made using a 3D-printed resin mold from patient-specific MRI data. The mold was filled with silicone Ecoflex™ 00-10 and mixed with Silc Pig® pigment additives to replicate the color and consistency of brain tissue. The dura mater was made from quick-drying silicone paste admixed with gray dye. The blood vessels were made from a silicone 3D-printed mold based on magnetic resonance imaging. Liquid containing paprika oleoresin dye was used to simulate blood and was pumped through the vessels to simulate pulsatile motion. Results: Seven residents and eight senior neurosurgeons were recruited to test our model. The participants reported that the size and anatomy of the elements were very similar to real structures. The model was helpful for training neuroendoscopic 3D perception and navigation. Conclusions: We developed an endoscopic third ventriculostomy training model using 3D printing technology that provides anatomical precision and a realistic simulation. We hope our model can provide an indispensable tool for young neurosurgeons to gain operative experience without exposing patients to risk.
Background: The advance in imaging techniques is useful for 3D models and printing leading to a real revolution in many surgical specialties, in particular, neurosurgery. Methods: We report on a clinical study on the use of 3D printed models to perform cranioplasty in patients with craniosynostosis. The participants were recruited from various medical institutions and were divided into two groups: Group A (n = 5) received traditional surgical education (including cadaveric specimens) but without using 3D printed models, while Group B (n = 5) received training using 3D printed models. Results: Group B surgeons had the opportunity to plan different techniques and to simulate the cranioplasty. Group B surgeons reported that models provided a realistic and controlled environment for practicing surgical techniques, allowed for repetitive practice, and helped in visualizing the anatomy and pathology of craniosynostosis. Conclusion: 3D printed models can provide a realistic and controlled environment for neurosurgeons to develop their surgical skills in a safe and efficient manner. The ability to practice on 3D printed models before performing the actual surgery on patients may potentially improve the surgeons’ confidence and competence in performing complex craniosynostosis surgeries.
Background: Anterior cervical discectomy and fusion (ACDF) is an often performed procedure in spine neurosurgery. These are often performed using an operating microscope (OM) for better illumination and visualization. But its use is limited to the surgeon and the assistant. There is difficulty in maneuvering long surgical instruments due to the limited space available. Exoscope (EX) has been used as an alternative to microscopes and endoscopes. We used an EX in patients undergoing ACDF for cervical spondylotic myelopathy.Methods: A prospective comparative trial was conducted to test the safety and usability of a low-cost EX compared to a conventional surgical binocular OM in ACDF. Twenty-six patients with degenerative cervical myelopathy symptoms were operated by ACDF assisted by the EX and OM between December 2021 and June 2022. The authors collected and compared data on operative time, intraoperative hemorrhage, hospital admission, and complications in the two groups.Results: There were no statistically significant differences between the two groups in mean operative time, hospital stay, or postoperative complications. The average intraoperative blood loss was significantly more in the OM group. There were no surgical complications related to the use of the EX or OM. The comfort level, preoperative setup and intraoperative adjustment of position and angle of the EX were rated higher than the OM group. The image quality, depth perception, and illumination were rated as inferior to that of the OM. The low-cost EX was rated to be superior to that of the OM with regard to education and training purposes.Conclusion: Our study showed that the low-cost EX appears to be a safe and effective alternative for OM-assisted ACDF with great comfort and ergonomics and serves as an essential tool for education and training purposes. However, some limitations of our EX included slightly inferior image quality and illumination when compared with the OM.
Background: The sciatic nerve (SN) is the widest nerve of the human body that exits the pelvis through the greater sciatic foramen, usually below the piriformis muscle (PM), and descends between the greater trochanter of the femur and ischial tuberosity of the pelvis to the knee. The aim of this paper is to examine and identify the SN variations in relation to the PM, its prevalence, pattern, and course. Methods: A prospective-descriptive cross-sectional study was carried out to determine the frequency of anatomical variations in the exit of the SN in relation with the PM in 20 anatomical bodies (corpses) of both genders, in equal numbers. Results: The dissection of 40 SNs in corpses of both sexes in equal numbers showed that the SN exited inferior to the PM in 37 lower limbs (92.5%); between the fascicles of the PM and inferior to the PM in two lower limbs (5%); and in one thigh, between the fascicles of the PM and superior to the PM (2.5%). Our study reported that the SN divides in its terminal branches more commonly in the proximal part of the popliteal fossa in 55% of cases, in the gluteal region in 35% of cases, and in the middle third of the thigh in 10% of cases. Conclusions: Anatomical variations of the SN in relation to the PM are challenging for the diagnostic and therapeutic procedure in many clinical and surgical cases. Rapid recognition of the SN changes makes surgical approaches more accurate and effective. Our study confirmed that the SN exits the pelvis most commonly below the PM, although some anatomical variations may occur.
22 December 2023 in Surgical Neurology International
Background: The main objectives of this paper are to outline the essential tools, instruments, and equipment needed to set up a functional microsurgery laboratory that is affordable for low-income hospitals and to identify cost-effective alternatives for acquiring microsurgical equipment, such as refurbished or donated instruments, collaborating with medical device manufacturers for discounted rates, or exploring local suppliers. Methods: Step-by-step instructions were provided on setting up the microsurgery laboratory, including recommendations for the layout, ergonomic considerations, lighting, and sterilization processes while ensuring cost-effectiveness, as well as comprehensive training protocols and a curriculum specifically tailored to enhance microsurgical skills in neurosurgery residents. Results: We explored cost-effective options for obtaining microsurgery simulators and utilizing open-source or low-cost virtual training platforms. We also included guidelines for regular equipment maintenance, instrument sterilization, and establishing protocols for infection control to ensure a safe and hygienic learning environment. To foster collaboration between low-income hospitals and external organizations or institutions that can provide support, resources, or mentorship, this paper shows strategies for networking, knowledge exchange, and establishing partnerships to enhance microsurgical training opportunities further. We evaluated the impact and effectiveness of the low-cost microsurgery laboratory by assessing the impact and effectiveness of the established microsurgery laboratory in improving the microsurgical skills of neurosurgery residents. About microsutures and microanastomosis, after three weeks of training, residents showed improvement in “surgical time” for ten separate simple stitches (30.06 vs. 8.65 min) and ten continuous single stitches (19.84 vs. 6.51 min). Similarly, there was an increase in the “good quality” of the stitches and the suture pattern from 36.36% to 63.63%. Conclusion: By achieving these objectives, this guide aims to empower low-income hospitals and neurosurgery residents with the necessary resources and knowledge to establish and operate an affordable microsurgery laboratory, ultimately enhancing the quality of microsurgical training and patient care in low-income countries.