Francisco Álvarez Guzmán

Francisco Álvarez Guzmán

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2022 in Journal of Dentistry
Verified
Journal Article
Open access
MGMiguel Gómez-Polo
Miguel Gómez-Polo
FGFrancisco Álvarez Guzmán
Francisco Álvarez Guzmán
RORocío Ortega
Rocío Ortega
CGCristina Gómez-Polo
Cristina Gómez-Polo
ABAbdul B. Barmak
Abdul B. Barmak
MRMarta Revilla-León
Marta Revilla-León
To assess the influence of the scan body geometry bevel location and implant angulation and position of complete-arch implant digital scans. Two definitive casts with 4 implant analogs placed parallel (P group) or angulated up to 30° (NP group) were fabricated. Five subgroups were created based on the scan body geometry bevel position: facial, mesial, distal, lingual, or random (F, M, D, L, and R subgroup). Casts were digitized using a laboratory scanner (reference) (7Series Desktop Scanner) and an intraoral scanner (TRIOS 3). The implant position discrepancies between the reference and experimental scans were calculated. Data was analyzed using 3-way ANOVA and Tukey tests (α = .05). The scan body geometry bevel position (P < .001) and the inter-implant distance (P < .001) were shown as significant predictors of the linear discrepancies obtained. The L subgroup had a significantly lower discrepancy compared with the other subgroups. Implant angulation (P < .001), the scan body geometry bevel position (P < .001), and the inter-implant distance (P < .001) were all significant predictors on the angular discrepancies obtained. The scan body geometry bevel location and implant angulation and position influenced the accuracy of the IOS tested. The lingual orientation obtained significantly better accuracy values compared with the other positions. The parallel implant analog position obtained better accuracy than the angulated positions. Lastly, the implant positioned in the dental arch where the intraoral digital scan was finished obtained significantly higher distortion than the contralateral implant.

24 April 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RSRocío Cascos Sánchez
Rocío Cascos Sánchez
LALaura Ortiz del Amo
Laura Ortiz del Amo
FGFrancisco Álvarez Guzmán
Francisco Álvarez Guzmán
JAJosé Luis Antonaya-Martín
José Luis Antonaya-Martín
Alicia CeleminAlicia Celemin
Alicia Celemin
MGMiguel Gómez-Polo
Miguel Gómez-Polo
(1) Background: Facial scanners are used in different fields of dentistry to digitalize the soft tissues of the patient’s face. The development of technology has allowed the patient to have a 3-dimensional virtual representation, facilitating facial integration in the diagnosis and treatment plan. However, the accuracy of the facial scanner and the obtaining of better results with respect to the manual or two-dimensional (2D) method are questionable. The objective of this clinical trial was to evaluate the usefulness and accuracy of the 3D method (a dual-structured light facial scanner) and compare it with the 2D method (photography) to obtain facial analysis in the maximum intercuspation position and smile position. (2) Methods: A total of 60 participants were included, and nine facial landmarks and five interlandmarks distances were determined by two independent calibrated operators for each participant. All measurements were made using three methods: the manual method (manual measurement), the 2D method (photography), and the 3D method (facial scanner). All clinical and lighting conditions, as well as the specific parameters of each method, were standardized and controlled. The facial interlandmark distances were made by using a digital caliper, a 2D software program (Adobe Photoshop, version 21.0.2), and a 3D software program (Meshlab, version 2020.12), respectively. The data were analyzed by SPSS statistical software. The Kolmogorov–Smirnov test revealed that trueness and precision values were normally distributed (p > 0.05), so a Student’s t-test was employed. (3) Results: Statistically significant differences (p ≤ 0.01) were observed in all interlandmark measurements in the 2D group (photography) to compare with the manual group. The 2D method obtained a mean accuracy value of 2.09 (±3.38) and 2.494 (±3.67) in maximum intercuspation and smile, respectively. On the other hand, the 3D method (facial scanner) obtained a mean accuracy value of 0.61 (±1.65) and 0.28 (±2.03) in maximum intercuspation and smile, respectively. There were no statistically significant differences with the manual method. (4) Conclusions: The employed technique demonstrated that it influences the accuracy of facial records. The 3D method reported acceptable accuracy values, while the 2D method showed discrepancies over the clinically acceptable limits.