Xiangpan Li

Dr. Xiangpan Li


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2012 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
XJXuesong Jiang
Xuesong Jiang
JXJian-Ping Xiao
Jian-Ping Xiao
YZYe Zhang
Ye Zhang
YXYing-Jie Xu
Ying-Jie Xu
XLXiangpan Li
Xiangpan Li
YLYe-Xiong Li
Ye-Xiong Li
Background: To evaluate the efficacy and outcomes of hypofractionated stereotactic radiotherapy (HSRT) for brain metastases > 3 cm. Methods: From March 2003 to October 2009, 40 patients with brain metastases larger than 3 cm were treated by HSRT. HSRT was applied in 29 patients for primary treatment and in 11 patients for rescue. Single brain metastasis was detected in 21 patients. Whole brain radiotherapy was incorporated into HSRT in 10 patients for primary treatment. HSRT boosts were applied in 23 patients. The diameters of the brain metastases ranged from 3.1 to 5.5 cm (median, 4.1 cm). The median prescribed dose (not including HSRT boosts) was 40 Gy (range, 20-53 Gy) with a median of 10 fractions (range, 4-15 fractions) to the 90% isodose line. The median dose of the boost was 20 Gy (range, 10-35 Gy) in 4 fractions (range, 2-10 fractions). Result: The median overall survival time was 15 months. The overall survival and local control rate at 12 months was 55.3% and 94.2%, respectively. Four patients experienced local progression of large brain metastases. Nine patients died of intracranial disease progression. One patient died of radiation necrosis with brain edema. Conclusion: HSRT was a safe and effective treatment for patients with brain metastases ranged from 3.1 to 5.5 cm. Dose escalation of HSRT boost may improve local control with an acceptable toxicity.

19 December 2011 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
XCXiu-Jun Chen
Xiu-Jun Chen
JXJian-Ping Xiao
Jian-Ping Xiao
XLXiangpan Li
Xiangpan Li
XJXuesong Jiang
Xuesong Jiang
YZYe Zhang
Ye Zhang
YLYe-Xiong Li
Ye-Xiong Li
Objective: To explore the risk factors of distant brain failure (DBF) for patients with brain metastasis (BM) who were treated with stereotactic radiotherapy alone and to group the patients on the basis of their risk levels. Methods and Materials: We retrospectively analyzed 132 newly diagnosed BM patients who were treated with stereotactic radiotherapy alone from May 2000 to April 2010. Kaplan-Meier and Cox proportional hazards regression analyses were performed for univariate and multivariate analyses. Results: The 1-year incidence rate of DBF was 44.7%, and the median DBF time (MDBFT) was 18 months. In multivariate analysis, the risk factors of DBF were the number of BMs greater than 1 (p = 0.041), uncontrolled extracranial disease (p = 0.005), interval time (IT) of less than 60 months between the diagnosis of primary tumor and BM (p = 0.024), and total volume of BM was greater than 6 cc (p = 0.049). Each risk factor was assigned 1 score. The median survival times for the patients with scores of 0-1, 2-3, and 4 were 31, 12, and 10 months, respectively, and the corresponding MDBFTs were not reached, 13, and 3 months, respectively, (p < 0.001). The crude DBF incidence rates in patients with scores of 0-1, 2-3, and 4 were 14.8%, 50.0%, and 76.9%, respectively, (p < 0.001). Conclusions: The patients with scores of 0-1 had a lower risk of DBF than the patients with higher scores did, and it may be reasonable to treat these patients with SRS alone and resort to whole-brain radiation therapy only for salvage. The patients with a score of 4 had the highest risk of developing DBF after stereotactic radiotherapy alone, these patients may be candidates for initial whole-brain radiation therapy or clinical trials. The patients with a score of 2-3 had a moderate risk of developing DBF, SRT alone combined with close clinical monitoring would be the optimal treatment regimen for such patients, and for those patients with difficulties in receiving close clinical mornitoring, SRT combined with WBRT will be more suitable.

11 August 2025 in Scientific Reports
Verified
Journal Article
Open access
HSHong-Bing Song
Hong-Bing Song
JXJing-Gang Xu
Jing-Gang Xu
XYXiong Yang
Xiong Yang
Zhifeng LiZhifeng Li
Zhifeng Li
SWSheng Wang
Sheng Wang
XLXiangpan Li
Xiangpan Li
This study investigated the impact of nuclear reaction cross-sections data from various nuclear data libraries on neutron parameters in Monte Carlo simulations using the PHITS code for accelerator-based BNCT (AB-BNCT). Specifically, it evaluated the effect of different proton data libraries-ENDF/B VII.1, ENDF/B VIII.1, CP2020, and JENDL-5.0-on the neutron yields from the 7Li(p, n)7Be reaction in a natural lithium target. The results showed that the calculated target neutron yields differed by up to 16.86%, with notable variations in the target neutron energy spectra. Furthermore, the study assessed the impact of neutron libraries-ENDF/B VII.1, ENDF/B VIII.0, ENDF/B VIII.1, JEFF-3.3, CENDL-3.2, and JENDL-5.0-on neutron beam parameters at the BSA exit, based on the neutron spectrum at the lithium target. It was found that the epithermal neutron intensity and fast neutron component calculated with the ENDF/B VIII.1 neutron library were 5.51%-8.61% and 19.04%-63.94% higher, respectively, than that obtained with the other neutron libraries, due to a more prominent neutron flux peak. The fast neutron component, calculated using the JENDL-5.0 neutron library, was 23.42%-63.94% lower compared to other libraries, while the gamma-ray component derived from the JEFF-3.3, CENDL-3.2, and JENDL-5.0 neutron libraries was 6.79%-10.08% higher than that from the ENDF/B series. Further analysis revealed that the discrepancies were primarily caused by differences in the neutron cross-section data of F, Pb, Mg, Cu, and H in specific neutron libraries. In particular, the differences in the neutron cross-sections of F and Pb accounted for the variations in the obtained BSA outlet spectra and neutron parameters when using the ENDF/B VIII.1 and JENDL-5.0 neutron libraries. The elevated gamma-ray component observed in the JEFF-3.3 and CENDL-3.2 neutron libraries, compared to the ENDF/B series, was largely due to the different cross-sections of Mg, Cu, and H. These findings underscored the considerable discrepancies arising from variations in nuclear data libraries and emphasized the critical importance of appropriate selection of nuclear data libraries for BNCT applications.

21 July 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
HSHongbing Song
Hongbing Song
JHJian Hu
Jian Hu
JHJunxiang He
Junxiang He
GMGuangdong Ma
Guangdong Ma
LCLan Cheng
Lan Cheng
XLXiangpan Li
Xiangpan Li
Purpose: To investigate the dosimetric impact of the calculation boundaries and dose calculation algorithms of radiotherapy in head and neck cancer patients with an opened oral cavity connected to the exterior by a hollow intraoral positioning stent.Methods and Materials: A homemade silicone phantom with an opened oral cavity was placed in a CIRS head phantom to model head and neck cancer patients with a hollow intraoral positioning stent. 3D‐CRT plans were designed on CT images of the phantom in Monaco and Pinnacle3 treatment planning systems (TPSs) with the same beam parameters. The default boundary and manually extrapolated boundary were both adopted in these two TPSs to explore the dosimetric impact on treatment plans. The nanoDot™ optically stimulated luminescence dosimeters (OSLDs) were chosen to measure the planned dose surrounding the oral cavity of the head phantom after calibration.Result: The doses in the air cavity and two measuring points at the joint area were dramatically changed from 0.0, 92.4 and 148.8 cGy to 177.8, 244.2 and 244.1 cGy in Monaco after adopting the extrapolated boundary. While the calculated doses at the same place were changed from 61.2, 143.7 and 198.3 cGy to 175.4, 234.7 and 233.2 cGy in Pinnacle3 with a similar calculation boundary. For the Monaco TPS, the relative errors compared to the OSLD measured doses were 2.94 ± 1.93%, 0.53 ± 8.64%, 2.65 ± 1.87% and 3.93 ± 1.69% at 4 measuring positions. In contrast, the relative errors 4.03 ± 1.93%, 4.85 ± 8.64%, 7.61 ± 1.87% and 5.61 ± 1.69% were observed in Pinnacle3.Conclusion: The boundary setting of an opened oral cavity in TPSs has a significant dosimetric impact on head and neck cancer radiotherapy. An extrapolated boundary should be manually set up to include the whole oral cavity in the dose calculation domain to avoid major dose deviations.

21 October 2024 in Advances in Radiotherapy & Nuclear Medicine
Verified
Journal Article
Open access
PDF file
HHHaonan Han
Haonan Han
HHHailing Hou
Hailing Hou
LQLin Qiu
Lin Qiu
CCChingyun Cheng
Chingyun Cheng
KXKeying Xu
Keying Xu
LXLiming Xu
Liming Xu
The total duration of radiotherapy for patients with cervical cancer should be limited to 56 days to optimize treatment outcomes. This study aimed to statistically evaluate the effects of extended radiotherapy duration on survival and complications in 649 patients with cervical cancer treated with brachytherapy at our institution from 2014 to 2019. All patients had undergone intensity-modulated external beam radiation therapy, with 525 receiving two-dimensional (2D) brachytherapy and 124 receiving three-dimensional (3D) brachytherapy. Using the inverse probability of treatment weighting (IPTW) and propensity score matching (PSM), clinical data regarding treatment duration, survival outcomes, and complications were analyzed. PSM revealed that overall survival (OS) did not significantly differ between patients receiving prolonged treatment (>56 days) and those receiving treatment for a standard duration ( 0.05). However, among patients who had received 2D brachytherapy, prolonged treatment correlated with increased recurrence and metastasis risks (P < 0.001); this trend was not evident in patients receiving 3D brachytherapy (P = 0.287). Higher FIGO stages were associated with worse OS and higher progression risks, which persisted post-IPTW adjustment. Extended radiotherapy duration was linked to a higher incidence of rectal and bladder reactions, particularly in the 2D group. Consequently, strictly controlling radiotherapy duration for patients receiving 2D brachytherapy is essential to reduce recurrence and metastasis risks. Close monitoring of rectal and bladder reactions is also recommended.