Human exposure to per- and polyfluoroalkyl substances also known as PFAS is an ongoing occupational and environmental health problem. This study seeks to characterise multiple pathways for firefighters' exposure to PFAS. PFAS were analysed in 688 environmental samples such as eggs, fruits, vegetables, dust, soil, surface swabs, appliance washes and water obtained from fire stations. Relevant exposure pathways were identified and daily intake levels were estimated using PFAS concentrations and exposure factors relevant to firefighters. Five PFAS including perfluorooctane sulfonic acid (PFOS), perfluorooctanoic acid (PFOA), perfluorohexane sulfonic acid (PFHxS), 6:2 fluorotelomer sulfonate (6:2 FTS), and 8:2 fluorotelomer sulfonic acid (8:2 FTS) were frequently detected in the samples. Based on the median concentrations in each sample type, PFOS was the most abundant contaminant in eggs (80%), fruits (52%), dust (81%), surface swab (66%), soil (83%) and appliance wash (31%) samples. On the other hand, PFHxS was most abundant in vegetables (77%) and 8:2 FTS in water (58%). The intake estimation results show that dietary exposure from ingestion of foods produced on fire stations was the predominant exposure pathway, representing 82% and 62% of firefighters' total PFAS intake under typical and worst-case exposure scenarios, respectively. Incidental ingestion and dermal absorption of PFAS in dust contributed 15% for typical and 34% for worst-case exposure scenarios. The relative contributions from incidental ingestion and dermal absorption of PFAS in soil and appliance washes were insignificant. Overall, the study identifies multiple exposure pathways relevant to career firefighters including consumption of food grown on fire stations, which has not previously been recognised within the occupational exposure context. The results suggest exposure control strategies that target foods produced on fire stations could substantially reduce firefighters' exposure to PFAS.
Firefighters are at a high risk of exposure to per- and polyfluoroalkyl substances (PFAS) due to their frequent use of PFAS-containing foams in training and emergency situations. This longitudinal study aimed to investigate the changes in serum PFAS levels among firefighters following cessation of their exposure to PFAS-containing foams. The study involved 130 firefighters from the South Australian Metropolitan Fire Services (SAMFS), and serum samples were collected at two time points: baseline in 2018-19 and follow-up in 2021-22. Along with the collection of samples, a survey questionnaire was administered to gather information on firefighters' employment and demographic characteristics. Regression models were employed to assess the association between these factors and the outcome variable (annual percentage change in serum PFAS concentration). The results indicated a decline in serum PFAS concentrations over time, with the main contaminants being perfluorooctane sulfonic acid (PFOS), perfluorohexane sulfonate (PFHxS), and perfluorooctanoic acid (PFOA). The median and Interquartile Range (IQR) of total PFAS (∑PFAS) concentration reduced from 21.5 ng/ml (IQR: 11 to 53 ng/ml) at baseline to 15 ng/ml (IQR: 8 to 33 ng/ml) at follow-up. On average, there was an annual reduction of 13%, 7%, and 4.4% in serum concentrations of PFOS, PFHxS, and PFOA, respectively. Firefighters under the age of 55, those who used PFAS in the past ten years, or those who had little to no frequency of PFAS exposure in their previous employment, encountered a significantly higher annual percentage reduction (P < 0.05) in both ∑PFAS and PFOS concentrations. None of the independent variables analysed could significantly predict the annual percentage change in PFOA and PFHxS. This study provides evidence for a declining temporal trend in serum PFAS concentrations among metropolitan firefighters following workplace interventions that involved the removal of PFAS-containing foams.
Accurate real-time dust monitoring methods are essential in workplaces where exposure to respirable crystalline silica (RCS) presents serious health risks. While real-time monitors are increasingly adopted due to their ability to quickly detect dust-generating activities, concerns remain regarding their accuracy compared to conventional gravimetric methods. This pilot study evaluated the performance of three real-time personal dust monitors: the SidePak™ AM520, Trolex XD1+, and Nanozen DustCount 9000, against a gravimetric reference in both field settings (South Australian quarries) and controlled laboratory environments. Pairwise comparisons of respirable dust (RD) concentrations were conducted across full work shifts. Geometric means from the real-time monitors were regressed against corresponding gravimetric measurements to derive correction coefficients, which were then used to estimate RCS exposure. Agreement between estimated and measured RCS values was assessed using Lin’s Concordance Correlation Coefficient (CCC). Field results revealed inconsistent accuracy for the SidePak™ and Nanozen monitors, with performance varying by task. For example, the SidePak™ overestimated RD by 51% for a truck driver but underestimated levels by up to 48% for other roles. The Trolex XD1+ consistently underestimated RD by 80–89%. All monitors underestimated dust levels under laboratory conditions. However, applying correction coefficients improved agreement with gravimetric data, yielding a high concordance for RCS estimates (Lin’s CCC = 0.89; 95% CI: 0.66–0.97). These findings highlight both the utility and limitations of real-time monitors. Site-specific calibration is essential to enhance their reliability, and further studies with larger datasets are recommended to refine correction factors and improve accuracy of real-time dust monitors.
Background: Respirable crystalline silica (RCS) presents persistent health risks in construction, and predictive exposure models offer a potential complement to traditional monitoring. This study evaluated the applicability of the British Columbia Construction Safety Alliance (BCCSA) Silica Control ToolTM for use in the construction sector in Victoria, Australia. Methods: A two-phase evaluation was undertaken. First, a desktop interrogation of the Tool’s underpinning data, statistical model development and documented limitations was performed, including statistical review. Second, a user trial was conducted with 12 Victorian industry stakeholders who completed realistic task scenarios within the Tool and generated Exposure Control Plans (ECPs). Qualitative feedback was obtained through observation and focus group discussion. Results: The interrogation demonstrated that the Tool is built on a large, iteratively improved North American exposure database, with well developed and statistically sound modelling framework; however, its predictive validity has not yet been independently evaluated using Australian exposure data. Stakeholders produced 14 ECPs across diverse silica-generating tasks, showing that the Tool responded sensitively to changes in task parameters and control selections. Thematic analysis identified five key themes: usability, regulatory alignment, clarity of terminology, gaps in task representation, and adherence to the hierarchy of controls. Participants saw strong potential for the Tool but emphasised the need for Australian data integration, clearer definitions, enhanced usability, and localised terminology. Conclusions: The BCCSA Silica Control ToolTM demonstrates a technically robust North American modelling framework and strong stakeholder acceptability, but Australian-specific validation and adaptation are required before adoption in Victoria. Incorporating Australian exposure data, tailoring terminology and ensuring alignment with local legislation are critical next steps.