MUSTAFA ARMAĞAN

Dr. MUSTAFA ARMAĞAN

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2016 in Materials and Manufacturing Processes
Verified
Journal Article
Closed access
MAMUSTAFA ARMAĞAN
MUSTAFA ARMAĞAN
AAA. Armağan Arici
A. Armağan Arici
Polymer matrix composite materials have been increasingly used in aerospace, defense, automotive and marine industries. In these fields, nontraditional machining method of abrasive water jet (AWJ) has been used significantly in order to form polymer matrix components. In this study, glass fiber reinforced vinyl ester composite plates have been investigated under various AWJ cutting parameters by using the Taguchi experimental design in detail. For Taguchi experimental design, experimental parameters of standoff distance, abrasive mass flow rate, traverse speed, pressure and material thickness were determined at three levels. Top kerf width and the surface roughness were investigated in order to understand the cutting performance. Finally, linear regression models were conducted and all performance parameters were examined using analysis of variance (ANOVA) and main effects plots. According to the overall test results, standoff distance was determined as the most effective one. The optimal parameter levels were obtained by the ‘main effects plots’, and finally, the predictive modeling was validated by performing the optimal combination of parameter levels.

6 September 2024 in Frontiers in Materials
Verified
Journal Article
Open access
PDF file
EAEray Abakay
Eray Abakay
MAMUSTAFA ARMAĞAN
MUSTAFA ARMAĞAN
YAYasemin Yıldıran Avcu
Yasemin Yıldıran Avcu
MGMert Guney
Mert Guney
BYB Yousif
B Yousif
Egemen AvcuEgemen Avcu
Egemen Avcu
Titanium (Ti) alloys have been widely used in biomedical applications due to their superior mechanical, physical, and surface properties, while improving their tribological properties is critical to widening their biomedical applications in the current era. The present review examines the recent progress made in enhancing the tribological performance of titanium alloys and titanium matrix composites for biomedical purposes. It specifically focuses on the progress made in biomedical coatings, mechanical surface treatment, and developing titanium matrix composites in terms of their processing, tribological testing conditions, and characterization. Despite thorough investigations, the specific testing procedures for evaluating the friction and wear properties of the alloy and/or biomedical component are still uncertain. The majority of researchers have selected test methods and parameters based on previous studies or their own knowledge, but there is a scarcity of studies that incorporate limb-specific tribological tests that consider the distinct kinematic and biological structure of human limbs. Since advanced microscopy has great potential in this field, a variety of advanced characterization techniques have been used to reveal the relationship between microstructural and tribological properties. Many coating-based strategies have been developed using anodizing, PEO, VD, PVD, nitriding, thermal spray, sol-gel, and laser cladding, however; composition and processing parameters are crucial to improving tribological behaviour. Reinforcing component type, amount, and distribution has dominated Ti matrix composite research. Ti grade 2 and Ti6Al4V alloy has been the most widely used matrix, while various reinforcements, including TiC, Al2O3, TiB, hydroxyapatite, Si3N4, NbC, ZrO2 have been incorporated to enhance tribological performance of Ti matrix. Mechanical surface treatments improve biomedical Ti alloys’ tribological performance, which is advantageous due to their ease of application. The implementation of machine learning methods, such as artificial neural networks, regression, and fuzzy logic, is anticipated to make a substantial contribution to the field due to their ability to provide cost-effective and accurate results. The microstructural and surface features of biomedical Ti alloys directly affect their tribological properties, so image processing strategies using deep learning can help researchers optimize these properties for optimal performance.

2 April 2021 in Materials and Manufacturing Processes
Verified
Journal Article
Closed access
MAMUSTAFA ARMAĞAN
MUSTAFA ARMAĞAN
Abrasive water jet (AWJ), which is a non-traditional machining method, is more widely used today. Various materials such as metals, ceramics, polymers, and composites can be easily machined with AWJ. In this study, cutting of St37 steel plates in stacked form with AWJ was investigated. The experiments were carried out according to the general full factorial design. Experimental parameters were inter-stack distance, traverse speed, and abrasive mass flow rate also each of these parameters was chosen at three levels. Surface roughness and kerf widths were examined to determine the cutting performance. Analysis of variance (ANOVA) of all outputs was provided and thus the effects of experimental parameters and their levels on cutting performance were found. The most effective parameters for surface roughness and kerf width in almost all conditions were abrasive mass flow rate and inter-stack distance, respectively. In addition, a concept for multi-simultaneous cutting was developed with mathematical differences of surface roughness and kerf taper angle. Thus, optimum levels of experimental parameters were found for minimum mathematical differences.

1 April 2024 in Machining Science and Technology
Verified
Journal Article
Closed access
MAMUSTAFA ARMAĞAN
MUSTAFA ARMAĞAN
AAA. Armağan Arıcı
A. Armağan Arıcı
The abrasive water jet method is an unconventional machining method used to process target materials. The method involves mixing pressurized water and abrasive particles in a chamber before sending...

1 January 2025 in Materials Research Express
Verified
Journal Article
Open access
Egemen AvcuEgemen Avcu
Egemen Avcu
MAMUSTAFA ARMAĞAN
MUSTAFA ARMAĞAN
YAYasemin Yıldıran Avcu
Yasemin Yıldıran Avcu
EAEray Abakay
Eray Abakay
EÇEmirhan Çalım
Emirhan Çalım
RYRıdvan Yamanoğlu
Rıdvan Yamanoğlu
Titanium alloys possess remarkable properties, such as high strength, biocompatibility, and resistance to corrosion. Nonetheless, both their surface and subsurface properties require improvements, particularly for applications where surface contact is unavoidable. The present study utilises an emerging mechanical surface treatment technique (water jet shot peening) for modifying the surface and subsurface characteristics of cold-rolled Ti6Al4V sheets. Water jet shot peening was applied on Ti6Al4V samples following an L18 full factorial experimental design, focusing on the variable parameters of process time, standoff distance, and shot mass flow rate. ANOVA indicated that the shot mass flow rate had the greatest impact on the roughness parameters (p < 0.0001). The roughness values of Ra, Rp, and Rv decreased as the shot’s mass flow rate increased, and this decrease was more pronounced as the standoff distance diminished. The surface morphologies of the samples were notably modified by plastic deformation resulting from the repeated impact of shots. The water jet shot peening method modified the grains within the microstructure near the surface region. The grains in the microstructure were oriented perpendicularly to the peening direction to a depth of 5.36 μm beneath the surface, even at minimal peening levels. The surface hardness increased by approximately 64% relative to the hardness of untreated Ti6Al4V alloy (512.43 Hv versus 311.52 Hv), attributed to significant plastic deformation and strain hardening induced by the high kinetic energy of the impacting shots during water jet peening.

12 September 2025 in Coatings
Verified
Journal Article
Open access
PDF file
Egemen AvcuEgemen Avcu
Egemen Avcu
Mert GuneyMert Guney
Mert Guney
Yasemin Yıldıran AvcuYasemin Yıldıran Avcu
Yasemin Yıldıran Avcu
MSMine Sulak
Mine Sulak
HUHüseyin Uzuner
Hüseyin Uzuner
Martin F.-X. WagnerMartin F.-X. Wagner
Martin F.-X. Wagner
Interest in textured surfaces for biomaterials and implants is increasing, with shot peening emerging as a promising method for surface modification. This study investigates the influence of conventional and fine shot peening on the surface morphology, topography, wettability, and antibacterial properties of biomedical-grade Ti6Al4V alloy. Peening was conducted using a custom-built, fully automated system, employing fine (100–200 µm) and coarse (700–1000 µm) shots using well-controlled sets of parameters. Both treatments introduced severe plastic deformation on the surface, resulting in increased roughness. Conventionally shot-peened samples exhibited deeper and wider dimples compared to finely peened ones. Surface wettability shifted from hydrophilic (contact angle: ~4°, untreated) to hydrophobic, reaching contact angles of ~91° and ~100° for fine and conventional shot peening, respectively. Antibacterial assays against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) were evaluated by normalizing colony counts to the untreated Ti6Al4V surface. The inherent antibacterial response of Ti6Al4V against E. coli was preserved after both shot peening treatments, showing no notable increase in bacterial proliferation. In contrast, adhesion of S. aureus increased, more notably on fine shot-peened surfaces, indicating a strain-specific response influenced by surface roughness and wettability. In summary, both fine and conventional shot peening altered the surface morphology, topography, and wettability of Ti6Al4V. At the same time, their antibacterial influence was strain-dependent, underscoring the need for careful parameter selection in biomedical applications.