Benedict Wilmes

Prof. Dr. Benedict Wilmes


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2006 in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
Verified
Journal Article
Closed access
PDF file
Benedict WilmesBenedict Wilmes
Benedict Wilmes
CRCarsten Rademacher
Carsten Rademacher
GOGudrun Olthoff
Gudrun Olthoff
DDDieter Drescher
Dieter Drescher

1 November 2008 in The Angle Orthodontist
Verified
Journal Article
Closed access
Benedict WilmesBenedict Wilmes
Benedict Wilmes
YSYu-Yu Su
Yu-Yu Su
DDDieter Drescher
Dieter Drescher
Objective: To analyze the impact of the insertion angle on the primary stability of mini-implants. Materials and Methods: A total of 28 ilium bone segments of pigs were embedded in resin. Two different mini-implant sizes (Dual-Top Screw 1.6 × 8 mm and 2.0 × 10 mm) were inserted at seven different angles (30°, 40°, 50°, 60°, 70°, 80°, and 90°). The insertion torque was recorded to assess primary stability. In each bone, five Dual-Top Screws were used to compensate for differences in local bone quality. Results: The angle of mini-implant insertion had a significant impact on primary stability. The highest insertion torque values were measured at angles between 60° and 70° (63.8° for Dual-Top 1.6 mm and 66.7° for Dual-Top 2.0 mm). Very oblique insertion angles (30°) resulted in reduced primary stability. Conclusions: To achieve the best primary stability, an insertion angle ranging from 60° to 70° is advisable. If the available space between two adjacent roots is small, a more oblique direction of insertion seems to be favorable to minimize the risk of root contact.

1 January 2008 in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
Verified
Journal Article
Closed access
PDF file
Benedict WilmesBenedict Wilmes
Benedict Wilmes
SOStephanie Ottenstreuer
Stephanie Ottenstreuer
YSYu-Yu Su
Yu-Yu Su
DDDieter Drescher
Dieter Drescher

1 July 2011 in International Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
Benedict WilmesBenedict Wilmes
Benedict Wilmes
DDD. Drescher
D. Drescher

1 December 2018 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
SGSimon Graf
Simon Graf
SVSivabalan Vasudavan
Sivabalan Vasudavan
Benedict WilmesBenedict Wilmes
Benedict Wilmes

1 July 2009 in The Angle Orthodontist
Verified
Journal Article
Closed access
Benedict WilmesBenedict Wilmes
Benedict Wilmes
DDDieter Drescher
Dieter Drescher
Objective: To test the hypothesis that the impact of the insertion depth and predrilling diameter have no effect on the primary stability of mini-implants. Materials and Methods: Twelve ilium bone segments of pigs were embedded in resin. After implant site preparation with different predrilling diameters (1.0, 1.1, 1.2, and 1.3 mm), Dual Top Screws 1.6 × 10 mm (Jeil, Korea) were inserted with three different insertion depths (7.5, 8.5, and 9.5 mm). The insertion torque was recorded to assess primary stability. In each bone, five Dual Top Screws were used as a reference to compensate for the differences of local bone quality. Results: Both insertion depth and predrilling diameter influenced the measured insertion torques distinctively: the mean insertion torque for the insertion depth of 7.5 mm was 51.62 Nmm (±25.22); for insertion depth of 8.5 mm, 65.53 Nmm (±29.99); and for the insertion depth of 9.5 mm, 94.38 Nmm (±27.61). The mean insertion torque employing the predrill 1.0 mm was 83.50 Nmm (±33.56); for predrill 1.1 mm, 77.50 Nmm (±27.54); for the predrill 1.2 mm, 61.70 Nmm (±28.46); and for the predrill 1.3 mm, 53.10 (±32.18). All differences were highly statistically significant (P < .001). Conclusions: The hypothesis is rejected. Higher insertion depths result in higher insertion torques and thus primary stability. Larger predrilling diameters result in lower insertion torques.