10 July 2023 in Construction Materials
Verified
Journal Article
Open access
PDF file
SMSarwar Hasan Mohmmad
Sarwar Hasan Mohmmad
PSPshtiwan Shakor
Pshtiwan Shakor
JMJaza H. Muhammad
Jaza H. Muhammad
MHMustafa Fahmi Hasan
Mustafa Fahmi Hasan
Moses KarakouzianMoses Karakouzian
Moses Karakouzian
The emission of carbon dioxide gas from the cement manufacturing industry has raised concerns about global warming. Geopolymer concrete (GC) is gaining attention as a sustainable and environmentally friendly alternative to traditional cement concrete. The current study focused on using local clay to synthesize and characterize metakaolin-based GC with varying percentages of nanosilica (NS) (1.5%, 3.0%, 4.5%, 6.0%, and 7.5% by weight of MK content) using NaOH/sodium silicate. The geopolymer specimens were cured at room temperature for 28 days, and their workability, compressive, tensile, and flexural strengths were measured to evaluate the influence of NS on the concrete’s mechanical properties. The study found that the compressive, tensile, and flexural strengths of the GC increased gradually up to 6.0% NS, but any further increase in its ratio resulted in a reduction in mechanical characteristics. The study concludes that the addition of 6.0% NS in metakaolin (MK)-based GC produces the highest mechanical properties, improving the compressive strength of the GC mix by 34.3% compared to the control GC mix and improving the flexural and split tensile strengths by 39% and 37%, respectively, compared to control GC strengths. Furthermore, the statistical analysis confirms nano-silica’s significant impact on geopolymer concrete’s mechanical properties, emphasizing its role in improving performance and sustainability as an alternative to cement-based materials.

19 January 2022 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
SMSarwar Hasan Mohmmad
Sarwar Hasan Mohmmad
MGMehmet E. Gülşan
Mehmet E. Gülşan
AÇAbdulkadir Çevik
Abdulkadir Çevik

4 February 2025 in Geotechnical and Geological Engineering
Verified
Journal Article
Closed access
PDF file
MAMukhtar Hamid Abed
Mukhtar Hamid Abed
IAIsraa Sabbar Abbas
Israa Sabbar Abbas
SMSarwar Hasan Mohmmad
Sarwar Hasan Mohmmad
ASAltuğ Saygili
Altuğ Saygili
AAAhmed Ali Agha
Ahmed Ali Agha

20 March 2024 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
MHMustafa Fahmi Hasan
Mustafa Fahmi Hasan
MHMustafa Fahmi Hasan
Mustafa Fahmi Hasan
HHHasan Fahmi Hasan
Hasan Fahmi Hasan
AMAlyaa Assad Mahdi
Alyaa Assad Mahdi
SMSarwar Hasan Mohmmad
Sarwar Hasan Mohmmad
MAMukhtar Hamid Abed
Mukhtar Hamid Abed
The study investigated how simulated notches within concrete-filled steel tube (CFST) columns affect their mechanical performance. It aimed to understand the impact of notch length, orientation, and location within the steel tubes on the behavior of these circular columns. Study conducted compressive tests on a total of 32 CFST specimens, varying in thickness (3 mm and 6 mm) and filled with High-Strength Concrete (HSC) or Normal-Strength Concrete (NSC). Four control specimens without notches served as reference points. Results indicated that CFST columns with notches exhibited reduced mechanical performance compared to those without notches. Notch parameters played a crucial role in this reduced performance. Notch length and orientation had a more significant influence than notch location. It also highlighted that the thickness of the steel tube was a paramount factor, surpassing the importance of concrete type. In summary, the study emphasized that presence of notches in CFST columns significantly impacted their load-bearing capacity, buckling behavior, and failure modes. Length and orientation of notches were identified as critical factors, with steel tube thickness being a dominant factor in determining overall mechanical performance of these columns. These findings provide valuable insights for structural engineers and designers working with CFST columns in various construction applications.

20 August 2024 in Iranian Journal of Science and Technology, Transactions of Civil Engineering
Verified
Journal Article
Closed access
PDF file
JMJaza Hassan Muhammad
Jaza Hassan Muhammad
SMSarwar Hasan Mohmmad
Sarwar Hasan Mohmmad

10 February 2022 in Periodica Polytechnica Civil Engineering
Verified
Journal Article
Closed access
PDF file
SMSarwar Hasan Mohmmad
Sarwar Hasan Mohmmad
MGMehmet Eren Gülşan
Mehmet Eren Gülşan
AÇAbdulkadir Çevik
Abdulkadir Çevik
This comprehensive experimental study aimed to determine the bond performance of basalt fiber reinforced polymer (BFRP) bars in geopolymer concrete (GC). The study examined the bond performance of BFRP bars and GC by considering several parameters, including bar diameters of 8, 10, and 12 mm, embedment lengths of 4, 8, and 12 db mm (where db is the diameter of the bar), concrete covers of 20, 40, and 70 mm and compressive strengths of 21.7 and 34.4 MPa. The study also compared the effect of the bar surface and bar type on GC bond performance. Eventually, the results were compared with ordinary concrete (OC). The obtained results indicated that an increase in the BFRP bar diameter results in a decrease in the average bond stress. Similarly, an increase in the length of the bond leads to a reduction in the bond stress. The specimen possessing a short embedment length failed due to bar pullout, while the specimens with a longer embedment length failed as a result of concrete splitting. The outcomes also showed that the strength of bond increases with an increase in compressive strength and cover thickness. Furthermore, the results also indicated that BFRP-reinforced GC has comparable bond performance to steel-reinforced GC and BFRP-reinforced OC and performed better than OC. Last, Comparisons between the existing bond-slip models were offered to demonstrate the best bond stress-slip model for FRP bars and GC for ascending branch up to ultimate bond stress of the bond slip curves and for whole curves.