Chicken is a major source of dietary protein worldwide. The dispersion and movement of chickens constitute vital indicators of their health and status. This is especially evident in Taiwanese native chickens (TNCs), a local variety which is high in physical activity when healthy. Conventionally, the dispersion and movement of chicken flocks are observed in patrols. However, manual patrolling is laborious and time-consuming. Moreover, frequent patrols increase the risk of carrying pathogens into chicken farms. To address these issues, this study proposes an approach to develop an automatic warning system for anomalous dispersion and movement of chicken flocks in commercial chicken farms. Embendded systems were developed to acquire videos of chickens from overhead view in a chicken house, in which approximately 20,000 TNCs were raised for a period of 10 wk. Each video was 5-min in length. The videos were transmitted to a remote cloud server and were converted into images. A You Only Look Once—version 7 tiny (YOLOv7-tiny) object detection model was trained to detect chickens in the images. The dispersion of the chicken flocks in a 5-min long video was calculated using nearest neighbor index (NNI). The movement of the chicken flocks in a 5-min long video was quantified using simple online and real-time tracking algorithm (SORT). The normal ranges (i.e., 95% confidence intervals) of chicken dispersion and movement were established using an autoregressive integrated moving average (ARIMA) model and a seasonal autoregressive integrated moving average with exogenous factors (SARIMAX) model, respectively. The system allows farmers to check up on the chicken farm only when the dispersion or movement values were not in the normal ranges. Thus, labor time can be saved and the risk of carrying pathogens into chicken farms can be reduced. The trained YOLOv7-tiny model achieved an average precision of 98.2% in chicken detection. SORT achieved a multiple object tracking accuracy of 95.3%. The ARIMA and SARIMAX achieved a mean absolute percentage error 3.71% and 13.39%, respectively, in forecasting dispersion and movement. The proposed approach can serve as a solution for automatic monitoring of anomalous chicken dispersion and movement in chicken farming, alerting farmers of potential health risks and environmental hazards in chicken farms.
Zebrafish is a well-established model organism for cardiovascular disease studies in which one of the most popular tasks is to assess cardiac functions from the heart beating echo-videos. However, current techniques are often time-consuming and error-prone, making them unsuitable for large-scale analysis. To address this problem, we designed a method to automatically evaluate the ejection fraction of zebrafish from heart echo-videos using a deep-learning model architecture. Our model achieved a validation Dice coefficient of 0.967 and an IoU score of 0.937 which attest to its high accuracy. Our test findings revealed an error rate ranging from 0.11% to 37.05%, with an average error rate of 9.83%. This method is widely applicable in any laboratory setting and can be combined with binary recordings to optimize the efficacy and consistency of large-scale video analysis. By facilitating the precise quantification and monitoring of cardiac function in zebrafish, our approach outperforms traditional methods, substantially reducing the time and effort required for data analysis. The advantages of our method make it a promising tool for cardiovascular research using zebrafish.
Precise tracking of rodent movement is a critical component of behavioral studies, particularly for nocturnal species where traditional methods, such as video tracking, are limited by environmental constraints and visibility. This study presents a novel application of ultra-wideband (UWB) sensor technology for high-precision tracking of rodent behaviors in both Line-of-Sight (LoS) and Non-Line-of-Sight (NLoS) conditions. The DecaWave DWM1001C module, integrated into a custom lightweight wearable device, was deployed in a controlled habitat measuring 122 by 61 centimeter (cm). Advanced signal processing methods, including Kalman filtering and phase-based (PB) localization, were implemented to improve positioning accuracy and mitigate NLoS errors. Experimental results demonstrate a mean localization error of 2.28 cm in LoS scenarios and with a maximum error of 6.2 cm in NLoS conditions, significantly outperforming existing methods. This research highlights the potential of UWB sensor systems for dynamic and nocturnal behavioral studies, providing an adaptable and reliable solution for tracking animal movements in complex environments.
This work investigates the use of external voltage resets to reduce drifting issues of iridium oxide (IrOx) pH sensing films. Two types of IrOx films prepared by sol–gel and electroplating techniques were examined comparing hydrous and anhydrous material characteristics. The thin-film IrO x allows inexpensive processing for flexible polyimide substrates enabling planar and monolithic integration for wearables and miniature pH sensors. Open circuit potential drifts and external voltage resets were investigated for freshly prepared electrodes and re-tested after 14 days. External resets were examined at different voltage levels. Sol–gel electrodes showed 57% and 81% drift improvement in acid and alkaline test solutions, respectively, while electroplated ones showed 84% and 88% improvements. Sensitivity and hysteresis were investigated after external resets and showed promising results. A total of 15 sol–gel and 15 electroplated electrodes were characterized. Differences in pH characteristics are attributed to different types of IrO x composition. The quicker response transitions and reduced potential drifts will enable reliable long-term pH monitoring and reduce frequent calibration for pH-sensing applications.
Electrodeposited amorphous hydrated iridium oxide (IrOx) is a promising material for pH sensing due to its high sensitivity and the ease of fabrication. However, durability and variability continue to restrict the sensor’s effectiveness. Variation in probe films can be seen in both performance and fabrication, but it has been found that performance variation can be controlled with potentiostatic conditioning (PC). To make proper use of this technique, the morphological and chemical changes affecting the conditioning process must be understood. Here, a thorough study of this material, after undergoing PC in a pH-sensing-relevant potential regime, was conducted by voltammetry, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS). Fitting of XPS data was performed, guided by raw trends in survey scans, core orbitals, and valence spectra, both XPS and UPS. The findings indicate that the PC process can repeatably control and conform performance and surface bonding to desired calibrations and distributions, respectively; PC was able to reduce sensitivity and offset ranges to as low as ±0.7 mV/pH and ±0.008 V, respectively, and repeat bonding distributions over ~2 months of sample preparation. Both Ir/O atomic ratios (shifting from 4:1 to over 4.5:1) and fitted components assigned hydroxide or oxide states based on the literature (low-voltage spectra being almost entirely with suggested hydroxide components, and high-voltage spectra almost entirely with suggested oxide components) trend across the polarization range. Self-consistent valence, core orbital, and survey quantitative trends point to a likely mechanism of ligand conversion from hydroxide to oxide, suggesting that the conditioning process enforces specific state mixtures that include both theoretical Ir(III) and Ir(IV) species, and raising the conditioning potential alters the surface species from an assumed mixture of Ir species to more oxidized Ir species.
Continuous non-invasive blood pressure (CNBP) monitoring is of the utmost importance in detecting and managing hypertension, a leading cause of death in the United States. Extensive research has delved into pioneering methods for predicting systolic and diastolic blood pressure values by leveraging pulse arrival time (PAT), the time difference between the proximal and distal signal peaks. The most widely employed pairing involves electrocardiography (ECG) and photoplethysmography (PPG). Possessing similar characteristics in terms of measuring blood flow changes, a recently investigated optical signal known as speckleplethysmography (SPG) showed its stability and high signal-to-noise ratio compared with PPG. Thus, SPG is a potential surrogate to pair with ECG for CNBP estimation. The present study aims to unlock the untapped potential of SPG as a signal for non-invasive blood pressure monitoring based on PAT. To ascertain SPG’s capabilities, eight subjects were enrolled in multiple recording sessions. A third-party device was employed for ECG and PPG measurements, while a commercial device served as the reference for arterial blood pressure (ABP). SPG measurements were obtained using a prototype smartphone-based system. Following the completion of three scenarios—sitting, walking, and running—the subjects’ signals and ABP were recorded to investigate the predictive capacity of systolic blood pressure. The collected data were processed and prepared for machine learning models, including support vector regression and decision tree regression. The models’ effectiveness was evaluated using root-mean-square error and mean absolute percentage error. In most instances, predictions utilizing exhibited comparable or superior performance to (i.e., SPG Rest ± 12.4 mmHg vs. PPG Rest ± 13.7 mmHg for RSME, and SPG 8% vs. PPG 9% for MAPE). Furthermore, incorporating an additional feature, namely the previous SBP value, resulted in reduced prediction errors for both signals in multiple model configurations (i.e., SPG Rest ± 12.4 mmHg to ±3.7 mmHg for RSME, and SPG Rest 8% to 3% for MAPE). These preliminary tests of SPG underscore the remarkable potential of this novel signal in PAT-based blood pressure predictions. Subsequent studies involving a larger cohort of test subjects and advancements in the SPG acquisition system hold promise for further improving the effectiveness of this newly explored signal in blood pressure monitoring.