An adaptive unknown input observer (AUIO) for polymer electrolyte membrane fuel cell system with time-delays is developed and applied to formulate a fault diagnosis algorithm for multiple actuator fault detection and isolation (MAFDI). In a scheme based on multiple-model, a group of observers are developed based on a model that describes the system in the presence of a specific actuator fault. The observers are used to generate fault-dependant residual signals. When a model matches the system, the residual signal is zero and becomes non-zero in case of a faulty scenario. Two types of actuator faults are considered namely stuck fault, where the inputs delivered by the faulty actuators are blocked to constant value, and loss of effectiveness fault. The effectiveness of the proposed AUIO and MAFDI algorithm is shown with simulation results.
15 March 2022 in Journal of The Institution of Engineers (India): Series B
An unknown input observer (UIO) based component fault detection and isolation (CFDI) technique for proton exchange membrane fuel cell system (PEMFCS) is presented. The algorithm is derived by assuming single component fault at any time instant and devised with the assumption that sensors and actuators are fault free. First, a number of UIOs are designed for PEMFCS in such a way that one particular observer will be sensitive to a particular component and residuals are determined. Then, a residual based CFDI algorithm is formulated which is not incorporated in previous works on fault diagnosis of such systems. The effectiveness of the algorithm is shown with simulation results of the cathode pressure model of PEMFCS. The results show novel UIO based component fault diagnosis of the system using decision table. <!----> <!----> <!----> <!---->