Chengliang Li

Dr. Chengliang Li


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
YHYanxue Han
Yanxue Han
YZYuquan Zheng
Yuquan Zheng
CLChao Lin
Chao Lin
ZJZhenhua Ji
Zhenhua Ji
HXHao Xue
Hao Xue
曲高曲悠扬 高
曲悠扬 高
Imaging spectrometers in a geostationary orbit have unique advantages for various applications ranging from atmospheric to ocean remote sensing. To increase remote sensing range, we developed an ultrawide FOV LWIR imaging spectrometer. We compared several spectrometers and picked the “Offner + center single prism” form, which can simplify the system structure and increase cryogenic adaptability, making it ideal for ultrawide FOV designs. However, to reduce background radiation in LWIR bands, the imaging spectrometer was cooled to 123 K, causing the image plane to deviate from the focal plane. Therefore, we propose a cryogenic refocusing method based on an inclined slit in this paper that employs the full width half maximum (FWHM) of the spectral response function (SRF) as the refocusing evaluation function. By analyzing the effect of deviation on FWHM, the refocusing principle is well explained. The slit is tilted to find the minimal function value, so the deviation amount is calculated using differences in FOVs corresponding to the minimum FWHM at different temperatures. Experiments show that the FWHM is nearly 2.1 pixels after refocusing and that the actual spectral resolution is within 120 nm after spectral calibration. The method reduced the design time and provided references for optical systems experiencing refocusing issues in remote sensing imaging.

30 December 2023 in Photonics
Verified
Journal Article
Open access
PDF file
曲高曲悠扬 高
曲悠扬 高
YZYuquan Zheng
Yuquan Zheng
LWLong Wang
Long Wang
CLChengliang Li
Chengliang Li
JZJialun Zhang
Jialun Zhang
SWShuo Wang
Shuo Wang
Trace gas measurement has a wide range of applications needed in industrial, medical, and environmental protection. With the evolution of time, the demand for real-time, sensitivity, and accuracy of gas detection has been increasingly heightened. Off-axis integrated cavity output spectroscopy (OA-ICOS) is an effective method for the high-sensitivity detection of trace gases. It uses an integrated cavity with two highly reflective mirrors to provide a long optical path, which guarantees its high sensitivity. However, as the reflectivity of the mirrors increases, the intensity of the output light decreases, and the signal-to-noise ratio decreases. This contradiction makes it difficult to achieve a long optical path and a high signal-to-noise ratio together. To combat this issue, this paper proposes a type of integrated cavity using a direct-injection method. This structure, under equivalent mirror conditions, can maintain an effective absorption optical path very close to the original off-axis integrated cavity while increasing the output light intensity hundreds of times. This enhancement increases the sensitivity of OA-ICOS.

7 July 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
HWHao Wu
Hao Wu
CLChao Lin
Chao Lin
CLChengliang Li
Chengliang Li
JZJialun Zhang
Jialun Zhang
曲高曲悠扬 高
曲悠扬 高
YZYuquan Zheng
Yuquan Zheng
The hyperspectral full-waveform LiDAR (HSL) system based on the supercontinuum laser can obtain spatial and spectral information of the target synchronously and outperform traditional LiDAR or imaging spectrometers in target classification and other applications. However, low detection efficiency caused by the detection of useless background points (ULBG) hinders its practical applications, especially when the target is small compared with the large field of view (FOV) of the HSL system. A novel vision-aided hyperspectral full-waveform LiDAR system (V-HSL) was proposed to solve the problem and improve detection efficiency. First, we established the framework and developed preliminary algorithms for the V-HSL system. Next, we experimentally compared the performance of the V-HSL system with the HSL system. The results revealed that the proposed V-HSL system could reduce the detection of ULBG points and improve detection efficiency with enhanced detection performance. The V-HSL system is a promising development direction, and the study results will help researchers and engineers develop and optimize their design of the HSL system and ensure high detection efficiency of spatial and spectral information of the target.