Chao Luo

Dr. Chao Luo

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2024 in Buildings
Verified
Journal Article
Open access
PDF file
YWYuexing Wu
Yuexing Wu
XWXiangchuan Wang
Xiangchuan Wang
FYFan Yonghui
Fan Yonghui
JSJun Shi
Jun Shi
CLChao Luo
Chao Luo
XWXinzhong Wang
Xinzhong Wang
In order to study the ultimate span of a concrete-filled steel tube (CFST) arch bridge, taking the structural strength, stiffness, and stability as the limiting conditions, the finite element analysis method is adopted to carry out research on the influence law of a single parameter of the pipe diameter, wall thickness, and cross-section height on the ultimate span of the arch axial shape. The result is used as a sample point to determine the ultimate span of the CFST arch bridge under multifactor coupling based on the response surface method. The finite element method is used to check the strength, stiffness, stability, number of segments and maximum lifting weight, steel content rate, and steel pipe concrete constraint effect coefficient of the CFST arch bridge under the ultimate span diameter. The results show that, when analyzed using a single parameter, the ultimate span diameter of the CFST arch bridge increases with the increase in the steel pipe diameter and the cross-section height, and then decreases. Moreover, it increases with the increase in the wall thickness of the steel pipe, and the CFST arch bridge reaches the ultimate span with the increase in the steel pipe wall thickness. When the pipe diameter is 1.38 m, the CFST arch bridge reaches the ultimate span; according to a multi-parameter coupling analysis, when the pipe diameter is 1.49 m, wall thickness is 37 mm, and cross-section height is 17 m, the CFST arch bridge reaches the ultimate span of 821 m, which meets all of the limiting conditions, and, at this point, the arch axial coefficient is 1.2. The results of the finite element calculation show that the structural strength, prior to the stiffness, stability, and other limitations, just reaches the critical value of the limiting conditions.

27 June 2023 in Buildings
Verified
Journal Article
Open access
PDF file
FYFan Yonghui
Fan Yonghui
JZJianting Zhou
Jianting Zhou
CLChao Luo
Chao Luo
JYJun Yang
Jun Yang
JXJingzhou Xin
Jingzhou Xin
SWShaorui Wang
Shaorui Wang
A reasonable and efficient loading scheme is needed to guarantee the success of large-scale bridge tests. In this study, an array-type, self-balancing pulley-group loading system was designed based on the world’s largest spanning arch bridge using a 1:10 scale model test. Automatic statistics of the required load at each loading point were realized using ANSYS, and a load optimization algorithm for loading points at different construction stages was proposed. Tests were carried out separately for the loading system using a single set of pulley groups and an array-type pulley group. Finite element models of the model bridge and the original bridge were established separately using ANSYS, and the stress results of different components during different construction stages of the main arch ring were compared. The research results show the following: (1) The load magnification factor of the single-pulley-group loading device is approximately 6.6 times, with a mechanical efficiency of 94.26%. (2) In the array-type loading system, the actual load at each loading point can reach the design value. The self-balancing characteristic of this system can eliminate the impact of vertical deformation of the structure on loading accuracy, verifying the reliability of the system. (3) The simulation results of the original bridge and the model bridge coincide well, and the stress of each component during the construction process has the same trend. At key construction stages, the maximum relative errors of the stress results of the rigid steel frame and the concrete inside the pipe of the two bridges are 8.33% and 9.34%, respectively, and the maximum absolute error of the bottom plate concrete is 0.66 MPa, verifying the correctness of the counterweight-optimization method. The loading scheme proposed in this paper can provide a reference for the design of loading systems with the same type of scale model test.

8 March 2017 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
CLChao Luo
Chao Luo
YWYuhang Wang
Yuhang Wang
WKWilliam J. Koshak
William J. Koshak
We seek to develop a self‐consistent representation of lightning NOx (LNOx) simulation in a large‐scale 3‐D model. Lightning flash rates are parameterized functions of meteorological variables related to convection. We examine a suite of such variables and find that convective available potential energy and cloud top height give the best estimates compared to July 2010 observations from ground‐based lightning observation networks. Previous models often use lightning NOx vertical profiles derived from cloud‐resolving model simulations. An implicit assumption of such an approach is that the postconvection lightning NOx vertical distribution is the same for all deep convection, regardless of geographic location, time of year, or meteorological environment. Detailed observations of the lightning channel segment altitude distribution derived from the NASA Lightning Nitrogen Oxides Model can be used to obtain the LNOx emission profile. Coupling such a profile with model convective transport leads to a more self‐consistent lightning distribution compared to using prescribed postconvection profiles. We find that convective redistribution appears to be a more important factor than preconvection LNOx profile selection, providing another reason for linking the strength of convective transport to LNOx distribution.

2 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
FYFan Yonghui
Fan Yonghui
CLChao Luo
Chao Luo
YZYin Zhou
Yin Zhou
Ligui YangLigui Yang
Ligui Yang
XLXinglin Li
Xinglin Li
JLJinlong Liao
Jinlong Liao
To study the evolution of stress on the ring and segment interfaces during the construction process of the concrete encapsulation of the main arch ring in a rigid-frame arch bridge, alongside its impact on the ultimate load-bearing capacity of the main arch ring, a 1:10 scale model experiment was conducted by taking the 600 m Tian’e Longtan Bridge as the prototype. The key cross-section concrete strain data were collected during the entire construction process of the main arch ring via fiber-optic strain sensors, which were used to investigate the stress evolution at ring and segment interfaces. ANSYS APDL was employed to simulate the ultimate bearing capacity under various loading conditions of two different finite element models, which were, respectively, formed segmentally and by single pouring. The results revealed that (1) after the closure of the concrete encapsulation of the main arch ring, the concrete stress in the cross-section exhibits significant stress disparities. At the same cross-section, the level of the web concrete stress can reach 76% of the floor concrete stress, while the roof concrete stress level is less than 20% of the floor concrete stress. (2) At the junction of two adjacent work planes, there are considerable differences in the stress levels of the concrete on both sides. After the closure of the main arch ring, the intersegment stress ratios of the floor, web, and roof concrete are 60~70%, 40~60%, and 0~5%, respectively. (3) Loading conditions remarkably affected the ultimate bearing capacity of the main arch ring. Under mid-span loading and 1/4 span symmetrical loading conditions, compared to single-pour concrete encapsulation, the ultimate bearing capacity of the main arch ring with concrete encapsulated by segmented and ring-divided pouring decreased by 19.16% and 5.23%, respectively, compared to single-pour concrete encapsulation. This suggests that the non-uniformity of stress distribution in the concrete sheath can lead to reductions in the ultimate bearing capacity of the arch ring.

30 May 2023 in Buildings
Verified
Journal Article
Open access
PDF file
ZLZengwu Liu
Zengwu Liu
YWYuexing Wu
Yuexing Wu
CWChengwei Wang
Chengwei Wang
FYFan Yonghui
Fan Yonghui
CLChao Luo
Chao Luo
SWShaorui Wang
Shaorui Wang
To investigate the reasonable range of the inclination angle of arch ribs, a spatial finite element method was employed based on a concrete-filled steel tube (CFST) basket-handle through an arch bridge with a span of 360 m. A spatial finite element model was established using Midas/Civil software, which was verified with actual bridge data. The effects of different arch rib inclination angles were investigated under static loads. The structural natural frequencies, linear elastic stability coefficients, internal forces, and displacements were comprehensively considered to determine the reasonable range of the inclination angle. The results show that when the inclination angle ranges between 8° and 10°, the first, third, and sixth natural frequencies of the structure are increased. It effectively improves the lateral and torsional stiffness of the arch ribs while ensuring optimal out-of-plane stability of the arch ribs. Compared with the parallel arch, the stability is improved by 20.2%. The effects of angle variation on displacement and internal force of the arch ribs were not significant. Considering all indicators, the optimal range of the inclination angle for the arch ribs of 300-m-level highway CFST arch bridges is suggested to be 8~10°.

18 July 2008 in Chinese Journal of Geochemistry
Verified
Journal Article
Closed access
PDF file
CLChao Luo
Chao Luo
DYDong Yang
Dong Yang
ZPZicheng Peng
Zicheng Peng
ZZZhaofeng Zhang
Zhaofeng Zhang
LWLiu Weiguo
Liu Weiguo
CZChenlin Zhou
Chenlin Zhou