To study a retrospective analysis of patients who presented to the emergency departments (ED) with complaints related to foreign body ingestions. Patients older than 16 years of age who presented to the ED between January 1(st) and December 31(st) of 2010 with complaints related to swallowed foreign bodies were identified from electronic health records and patient charts. A total of 100 patients presented with a complaint of foreign body ingestion during the study period. Overall, an X-ray was performed on 75 patients, and a fiberoptic evaluation was performed on 45 patients. A foreign body was detected in 46 (46%) patients. The diagnostic yield of the X-ray was 27 (36%) out of 75 patients, while the diagnostic yield of the fiberoptic evaluations was 21 (47%) out of 45 patients. The detected foreign bodies were mostly located in the esophagus (17 out of 46 foreign bodies detected). When the types of ingested foreign bodies were evaluated, 52 (52%) patients reported ingesting food, and 19 (19%) patients reported swallowing pins. An X-ray was performed on 33 patients with accidental food ingestions but yielded a positive result in only two cases. In 12 out of 21 patients with accidental food ingestion who underwent fiberoptic evaluation, the foreign material was detected and removed. Plain radiography is helpful in the localization of radiopaque swollen foreign bodies, while fiberoptic methods are useful as both diagnostic and therapeutic tools, regardless of radiopacity.
1 January 2017 in The American Journal of Emergency Medicine
Pneumonia is the most serious clinical presentation of COVID-19. This study aimed to determine the demographic, clinical, and laboratory findings that can properly predict COVID-19 pneumonia. This study was conducted in the Gazi University hospital. All hospitalized patients with confirmed and suspected SARS-CoV-2 infection between 16 March 2020 and 30 April 2020 were analyzed retrospectively. COVID-19 patients were separated into two groups, pneumonia and nonpneumonia, and then compared to determine predicting factors for COVID-19 pneumonia. Variables that had a P-value of less than 0.20 and were not correlated with each other were included in the logistic regression model. Of the 247 patients included in the study 58% were female, and the median age was 40. COVID-19 was confirmed in 70.9% of these patients. Among the confirmed COVID-19 cases, 21.4% had pneumonia. In the multivariate analysis male sex (P = 0.028), hypertension (P = 0.022), and shortness of breath on hospital admission (P = 0.025) were significant factors predicting COVID-19 pneumonia. Shortness of breath, male sex, and hypertension were significant for predicting COVID-19 pneumonia on admission. Patients with these factors should be evaluated more carefully for diagnostic procedures, such as thorax CT.
1 April 2021 in Turkish Journal of Emergency Medicine
OBJECTIVE: Whether the use of metronome affects the quality of cardiopulmonary resuscitation (CPR) remains unclear. In this study, we investigated the effect of metronome use on CPR quality. METHODS: This was a prospective, simulation-based CPR manikin study. There were two phases: without and with metronome use. Chest compression was performed for 2 min, and three CPR quality criteria including chest compression depth, recoil, and rate were recorded with TrueCPR Feedback Device in both phases. RESULTS: In all, 102 resident physicians were included. The achievement of optimal chest compression depth and complete recoil was better with metronome use than without (83% and 77% vs. 78% and 39%, P ≤ 0.001, respectively). Optimal chest compression rate was also reached with metronome use because the range of the compression rate was closer to the normal limits than those without metronome use (110 [interquartile range (IQR) 109–113] vs. 120 [IQR 109–129], P ≤ 0.001). Of all the participants, 70.6% stated that metronome use had a positive effect on their performance during the CPR application and 66.7% stated that they wished to use the metronome in their daily practice. CONCLUSION: Using a metronome during simulation-based CPR improved the compression depth and recoil by fixing chest compression rate. We suggested that metronome should be used in CPR trainings of health-care professionals.