Hyperpolarized129Xe dissolved in a lipid emulsion constitutes an NMR tracer that can be injected into the blood stream, enabling blood‐flow measurement and perfusion imaging. A small volume (0.15 ml) of this tracer was injected in 1.5 s in rat carotid and129Xe MR spectra and images were acquired at 2.35 T to evaluate the potential of this approach for cerebral studies. Xenon spectra consistently showed two resonances, at 194.5 ppm and 199.0 ppm relative to the gas peak. The signal‐to‐noise ratio (SNR) obtained for the two peaks was sufficient (ranging from 12 to 90) to follow their time courses. 2D transverse‐projection xenon images were obtained with an in‐plane resolution of 900 μm per pixel (SNR range 8–15). Histological analysis revealed no brain damage except in two rats that had received three injections. Magn Reson Med 46:208–212, 2001.
Localization of regions with increased uptake of radiotracer in small-animal SPECT is greatly facilitated when using coregistration with anatomic images of the same animal. As MRI has several advantages compared with CT (soft-tissue contrast and lack of ionizing radiation) we developed a SPECT/low-field MRI hybrid device for small-animal imaging. Methods: A small-animal single-pinhole γ-camera (pinhole, 1.5 mm in diameter and 12 cm in focal length) adjacent to a dedicated low-field (0.1 T) small MR imager (imaging volume, 10 × 10 × 6 cm3) was used. The animal was placed in a warmed nonmagnetic polymethyl methacrylate imaging cell for MR acquisition, which was followed immediately by SPECT after translation of the imaging cell from one modality to the other. 3-Dimensional T1-weighted sequences were used for MRI. Phantom studies enabled verification of a low attenuation (10%) for 99mTc and 201Tl and a very slight increase in Compton scattering due to the radiofrequency coil and polymethyl methacrylate imaging cell. Results: SPECT/MRI data acquisition and image coregistration of selected examples using different radiotracers for lungs, kidneys, and brain were obtained in 3 nude mice with isotropic spatial resolutions of 0.5 × 0.5 × 0.5 mm3 for MRI and 1 × 1 × 1 mm3 for SPECT. The total acquisition time for combined SPECT and MRI lasted 1 h 45 min. Conclusion: A low-magnetic-field strength of 0.1 T is a simple and useful solution for a small-animal dual-imaging device combining pinhole SPECT with the adjacent MR imager.
The assessment of the three-dimensional architecture of collagen fibers inside vessel walls constitutes one of the bases for building structural models for the description of the mechanical behavior of these tissues. Multiphoton microscopy allows for such observations, but is limited to volumes of around a thousand of microns. In the present work, we propose to observe the collagenous network of vascular tissues using micro-CT. To get a contrast, three staining solutions (phosphotungstic acid, phosphomolybdic acid and iodine potassium iodide) were tested. Two of these stains were showed to lead to similar results and to a satisfactory contrast within the tissue. A detailed observation of a small porcine iliac vein sample allowed assessing the collagen fibers orientations within the medial and adventitial layers of the vein. The vasa vasorum network, which is present inside the adventitia of the vein, was also observed. Finally, the demonstrated micro-CT staining technique for the three-dimensional observation of thin soft tissues samples, like vein walls, contributes to the assessment of their structure at different scales while keeping a global overview of the tissue.