Background: Supracondylar humerus (SCH) fractures are some of the most common fractures in pediatric patients with surgery typically consisting of either open or closed reduction with internal fixation. The aim of this meta-analysis was to identify patient, injury, and administrative factors that are associated with treating pediatric SCH fractures with open techniques. Methods: Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, PubMed and CINAHL database searches were conducted for studies from 2010 to 2023 that made direct comparisons between open reduction and internal fixation (ORIF) and closed reduction and percutaneous pinning (CRPP) for treating SCH fractures in the pediatric population. The search terms used were “pediatric” AND “SCH fracture” OR “distal humerus fracture.” Screening, quality assessment, and data extraction were performed by 4 reviewers. After testing for heterogeneity between studies, data were aggregated using random-effects model analysis. Results: Forty-nine clinical studies were included in the meta-analysis. Summated, there were 94,415 patients: 11,329 treated with ORIF and 83,086 treated with CRPP. Factors that were significantly associated with greater rates of ORIF included obesity (p = 0.001), Gartland type IV fractures (p < 0.001), general neurological deficits (p = 0.019), and ulnar nerve deficits (p = 0.003). Gartland type II (p = 0.033) and medially displaced fractures (p = 0.011) were significantly associated with lower rates of ORIF. Secondary analysis showed cross-pinning constructs (p = 0.033) and longer hospital stays (p = 0.005) are more likely to be observed in patients undergoing ORIF compared with CRPP. Conclusion: This meta-analysis demonstrates that factors such as obesity, fracture displacement, and concomitant nerve deficits are more likely to require ORIF as opposed to CRPP. Level of Evidence: Therapeutic Level III.
Summary: A single implant all-internal magnet-driven bone transport nail (BTN—NuVasive Specialized Orthopaedics Inc) has recently been introduced as a treatment method for segmental tibial bone defects. This innovation provides promise in the management of segmental bone defects because it negates numerous complications associated with circular external fixation and the need for multiple implants when considering hybrid plate-assisted bone segment transport constructs. Given the novelty of the BTN, description of the surgical application and patient outcome measures are scarce in the current literature. To date, we have treated 4 patients with an average age of 27 years (range 19–44 years) using the BTN for segmental tibial defects ranging from 50 to 128 mm. We have accumulated data over an average follow-up of 18.07 months (range 12.96–25.13 months), demonstrating good patient tolerance of the device. Three patients successfully completed their treatment course with a calculated average bone healing index of 41.4 days/cm (range 31.41–54.82 days/cm). One patient was noted to experience an asymptomatic docking site nonunion requiring subsequent surgery for nonunion repair. Implant-associated complications included symptomatic implant, axial malalignment, docking site nonunion, and external remote control technical malfunction. Injury-related complications were encountered and noted to include: superficial infection, wound dehiscence, peroneal tendonitis, and joint rigidity. In this study, the authors present a case series using this implant to date and discuss our experiences with the BTN with reference to clinical indications, tibial bone preparation, BTN implantation, transport protocol, docking site procedure, and clinical/radiographic outcomes.
3 February 2024 in Arthroscopy, Sports Medicine, and Rehabilitation
Purpose: To evaluate the reliability of the perfect circle methodology for measurement of glenoid bone loss in patients with anterior glenohumeral instability. Methods: We performed a chart review of retrospectively collected patients who underwent isolated arthroscopic anterior labral repair between January 1 and June 30, 2021, using our institution’s electronic medical records. The inclusion criteria included isolated anterior shoulder instability with anterior labral repair and corroborated tears on magnetic resonance imaging. A total of 9 raters, either sports or shoulder and elbow fellowship‐trained orthopaedic surgeons, each evaluated the affected shoulder magnetic resonance imaging scans twice, with a minimum of 2 weeks between measurements. Measurements followed the “perfect circle” technique and included projected anterior‐to‐posterior glenoid diameter, amount of posterior bone loss, and percentage of posterior bone loss. Intrarater reliability and inter‐rater reliability were then determined by calculating intraclass correlation coefficients (ICCs). Results: Ten consecutive patients meeting the selection criteria were chosen for inclusion in this analysis. Average estimated bone loss for the cohort was 2.45 mm, and the mean estimated glenoid diameter of the involved shoulder was 28.82 mm. The average percentage of bone loss measured 8.54%. The ICC for interobserver reliability was 0.55 for the perfect circle diameter and 0.17 for the anterior bone loss measurement (poorly to moderately reliable). The ICC for intraobserver reliability was 0.69 for the perfect circle diameter and 0.71 for anterior bone loss (moderately reliable). Conclusions: The perfect circle technique for estimating anterior glenoid bone loss on magnetic resonance imaging was found to have moderate intrarater reliability; however, reliability between observers was found to be moderate to poor. Level of Evidence: Level IV, diagnostic case series.
Background: The purposes of this study were to analyze the trends in Oxford level of evidence (LOE), LOE of most-cited articles, and association between LOE and journal impact factor (IF) and SCImago Journal Rank (SJR) over a 10-year period (2009-2018) in 3 prominent hand surgery journals, specifically HAND, Journal of Hand Surgery ( American Volume) ( JHS), and Journal of Hand Surgery ( European Volume) ( JHSE). Methods: All articles published from 2009 to 2018 in HAND, JHS, and JHSE were reviewed for assigned or available LOE. Data were pooled and analyzed for trends in LOE; relationship among IF, SJR, and LOE; and citation density. Results: A total of 3921 total publications were tabulated from 2009 to 2018, with the majority of studies being level V (1700, 43%) and fewer studies being level I (146, 4%). Over the 10-year study period, there was no significant change in frequency of level I studies for any journal. HAND trended significantly toward higher LOE, JHS trended toward higher LOE, and JHSE trended toward decreased LOE without significance. Among all journals, the annual number of articles and the average LOE were independent significant predictors of IF and SJR. Statistically significant correlations were found between citation density and LOE for JHS and HAND. Conclusions: Higher quality evidence is becoming more prevalent in the hand surgery literature over the past 10 years. Annual articles, average LOE, and level I and II and level IV articles were significant predictors of increasing IF and SJR.