G. Koperundevi

Dr. G. Koperundevi


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2008 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
RSRamanujam Sarathi
Ramanujam Sarathi
GKG. Koperundevi
G. Koperundevi
DC power transmission is gaining considerable importance and converter transformers form an important component in it. An insulation of these transformers is stressed by both ac and dc voltages. Particle contamination is one of the major problems in insulation structures as it generates partial discharges (PD). If a particle is moving between the ground electrode and barrier, the magnitude of partial discharges formed is less compared to that of its movement between two metal electrodes. On the other hand, when the particle is lying over the barrier insulation material, it does not lead to any partial discharge activities as observed under ac/dc voltages. Broadband measurement of UHF signals produced by partial discharges due to particle movement in transformer oil under dc voltages, at high applied electric fields, indicates that the frequency content of the signal lies in the entire UHF range of 300 MHz - 3 GHz. Narrow band measurements of UHF signal due to PD formed by particle movement, at 1 GHz, indicates that, in the presence of barrier, an increase in applied voltage results in increase in number of partial discharge pulses. This phenomenon occurs in converse in oil gap without any barrier. In the presence of barrier, the sequential movement of particle occurs and the magnitude of discharges increases with increase in applied voltage, irrespective of polarity of the dc voltage. The number of discharges that occur under ac voltage is high compared to the dc voltages.

4 September 2009 in IET Science, Measurement & Technology
Verified
Journal Article
Closed access
RSRamanujam Sarathi
Ramanujam Sarathi
GKG. Koperundevi
G. Koperundevi
Converter transformers play an important role in the high-voltage DC power transmission system. The insulation of these transformers is stressed by both AC and DC voltages. Particle contamination is one of the major problems in insulation structures, as they generate partial discharges. A methodical experimental study was carried out to understand the partial discharge formation because of single macroscopic conducting particle movement in transformer oil at different temperatures under DC voltages using ultra-high-frequency (UHF) technique. It is observed that the single particle moves in the vertical electrode gap under the DC voltage, and generates UHF signal in the range of 1–3 GHz. At high electric fields, the levitated particle sometime floats in the oil medium and as and when the applied voltage is removed, the particle slowly drops down. When it comes in contact with ground electrode, it generates UHF signals with the frequency content lying in the range of 1–3 GHz. Oil breakdown tests were carried out (without any particle in the oil electrode gap) under DC voltages and fast Fourier transform (FFT) analysis of the signal generated by the UHF sensor because of breakdown indicates that the frequency content of the UHF sensor signal lies up to 1 GHz.

1 December 2010
Verified
Conference Paper
Closed access
GKG. Koperundevi
G. Koperundevi
MGM. K. Goyal
M. K. Goyal
SDSunil Das
Sunil Das
NRN. K. Roy
N. K. Roy
RSRamanujam Sarathi
Ramanujam Sarathi
One of the major causes of failure of converter transformer is the incipient discharges caused due to deterioration of insulation. The insulation in the converter transformers is stressed not only by AC voltages but also with remnant DC voltages. The Acoustic Emission (AE) Technique can identify such incipient discharges in the converter transformer. In the present work, experimental studies were carried out by simulating various incipient discharges such as corona discharge, partial discharge (PD) and surface discharge in an insulation test cell under AC and DC voltages by using AE Technique. The bandwidth of the AE sensor used in the present study is of wide band type and the bandwidth lies in the range of 100 kHz-1 MHz. It is observed that AE signals produced due to different incipient discharges are having different dominant frequency range, amplitude, rise time, number of pulses and energy. To classify the discharges an innovative methodology is adopted by constructing the ternary plot from the FFT output of AE signal generated by the incipient discharges.

1 January 2024 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
VPV. Paquianadin
V. Paquianadin
KSK. Navin Sam
K. Navin Sam
GKG. Koperundevi
G. Koperundevi
Introduction. In recent times, there has been a growing popularity of photovoltaic (PV) systems, primarily due to their numerous advantages in the field of renewable energy. One crucial and challenging task in PV systems is tracking the maximum power point (MPP), which is essential for enhancing their efficiency. Aim. PV systems face two main challenges. Firstly, they exhibit low efficiency in generating electric power, particularly in situations of low irradiation. Secondly, there is a strong connection between the power output of solar arrays and the constantly changing weather conditions. This interdependence can lead to load mismatch, where the maximum power is not effectively extracted and delivered to the load. This problem is commonly referred to as the maximum power point tracking (MPPT) problem various control methods for MPPT have been suggested to optimize the peak power output and overall generation efficiency of PV systems. Methodology. This article presents a novel approach to maximize the efficiency of solar PV systems by tracking the MPP and dynamic response of the system is investigated. Originality. The technique involves a multivariate linear regression (MLR) machine learning algorithm to predict the MPP for any value of irradiance level and temperature, based on data collected from the solar PV generator specifications. This information is then used to calculate the duty ratio for the boost converter. Results. MATLAB/Simulink simulations and experimental results demonstrate that this approach consistently achieves a mean efficiency of over 96 % in the steady-state operation of the PV system, even under variable irradiance level and temperature. Practical value. The improved efficiency of 96 % of the proposed MLR based MPP in the steady-state operation extracting maximum from PV system, adds more value. The same is evidently proved by the hardware results.

20 August 2025 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
RCRinki Roy Chowdhury
Rinki Roy Chowdhury
GKG. Koperundevi
G. Koperundevi
VAVenkadesan Arunachalam
Venkadesan Arunachalam
Predictive current control (PCC) is an effective technique for managing constrained nonlinear systems requiring high dynamic performance, especially in industrial and transportation applications. This article presents a robust multivector (MV) PCC scheme for electric vehicle (EV) induction motor (IM) drives, designed to maintain a fixed switching frequency with improved performance. The scheme combines symmetric three-vector PCC with slip-speed based dwelling time to introduce a simplified voltage vector (VV) preselection method, covering all operating modes and ensuring accurate reference voltage tracking, enhanced sector identification, and reduced computational complexity. Additionally, a Maximum Torque Per Ampere (MTPA) strategy is integrated to extend the speed range, ensuring efficient performance both below and above the rated speed while maintaining voltage constraints. Experimental results demonstrate the proposed scheme’s superior dynamic response, computational efficiency, and wide-speed adaptability for EV using extra-urban driving cycle (EUDC) driving scheme.

1 July 2018
Verified
Conference Paper
Closed access
GRG Nithin Reddy
G Nithin Reddy
MDMohammad Danish
Mohammad Danish
YBYadala Syam Babu
Yadala Syam Babu
GKG. Koperundevi
G. Koperundevi
Agriculture is a field that uses a lot of water. Most of the time, this resource is not used efficiently and substantial amounts of water are wasted. Farmers tend to use more water than required by manual techniques hence wasting them. Moreover time is also being wasted to test the quality of soil for crop laying as the soil needs to be tested in the lab for the minerals, pH content etc. for which they need to submit the samples of soil to the laboratory. The present era farmers in India have been using the manual control irrigation technique in which the farmer irrigate plant at regular interval of time. Improper watering may cause immature growth of crops. Also, the crop needs fertilizers based on different soil types for which the soil sample is tested in the laboratories for mineral content. These problems are addressed in the proposed system. In the proposed system irrigation take place only when there is a requirement of water. Also, if the soil quality is required to be tested for the type of crop, it can also be displayed with all the necessary details of essential nutrients which are Nitrogen, Phosphorus and Potassium.