Yanjiang Huang

Dr. Yanjiang Huang


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2022 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
YHYanjiang Huang
Yanjiang Huang
JKJianhong Ke
Jianhong Ke
XZXianmin Zhang
Xianmin Zhang
JOJun Ota
Jun Ota
Model-based control can provide high-accuracy performance over position-based or velocity-based control. Therefore, to employ model-based control in industrial robots, it is important to estimate the dynamic parameters as accurately as possible. However, traditional estimation methods, such as least squares (LS), are not sufficiently accurate, and the feasibility of dynamic parameters cannot be guaranteed. In this article, an iterative hybrid least square (IHLS) algorithm is proposed to estimate the base parameters of industrial robots by dividing the identification processes into two loops. The inner loop integrates a linear matrix inequality with the semidefinite programming technique to guarantee physical feasibility and reuses the torque deviations between the measured torque and predicted torque to estimate the base parameters of the robot, while the outer loop substitutes the Stribeck friction model for the Coulomb-viscous friction model to estimate the joint friction torque. Moreover, backpropagation neural network (BPNN) is introduced to further estimate the joint friction torque based on the Stribeck friction model. Experiments are conducted on two industrial robots, and four methods are compared in dynamic parameter identification. Experimental results show that the hybrid approach of the IHLS algorithm with the BPNN has the best performance among the four methods.

23 October 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YHYanjiang Huang
Yanjiang Huang
YCYanlin Chen
Yanlin Chen
XZXianmin Zhang
Xianmin Zhang
HZHongchuan Zhang
Hongchuan Zhang
CSChunyu Song
Chunyu Song
JOJun Ota
Jun Ota
Safety design of robot arm is important for human-robot interaction. In this article, an anthropomorphic seven-DOF cable-driven manipulator, including a three-DOF shoulder joint module, a one-DOF elbow joint module, and a three-DOF wrist joint module, is proposed for human-robot interaction. These three joint modules are connected serially and the motion transmission is realized by rope. The joint stiffness and workspace of joint module are numerically analyzed and compared to that of the human arm joint. A protype of manipulator is machined and used to evaluate the joint stiffness and workspace of the joint module through experiments. The mass of the designed manipulator is approximately 4.8 kg, which is similar to that of a human arm. The stiffness of elbow joint is 185.25 N·m/rad in positive direction and 133.75 N·m/rad in negative direction, which is smaller than that of the human elbow joint. The stiffness of wrist joint is 48.25 N·m/rad. The stiffness of shoulder joint under two configurations is 138 and 124 N·m/rad. The workspace matching index (WMI) is used to evaluate the workspace of joint module by comparing to that of the human arm joint. The WMI of the developed shoulder joint is approximately 40% of the human shoulder joint due to the structure constraint. While the workspaces of the developed elbow joint and wrist joint are the same with that of human joint.

1 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
XZXianmin Zhang
Xianmin Zhang
YZYanglong Zheng
Yanglong Zheng
JOJun Ota
Jun Ota
YHYanjiang Huang
Yanjiang Huang
This paper focuses on peg-in-hole assembly based on a two-phase scheme and force/torque sensor (F/T sensor) for a compliant dual-arm robot, the Baxter robot. The coordinated operations of human beings in assembly applications are applied to the behaviors of the robot. A two-phase assembly scheme is proposed to overcome the inaccurate positioning of the compliant dual-arm robot. The position and orientation of assembly pieces are adjusted respectively in an active compliant manner according to the forces and torques derived by a six degrees-of-freedom (6-DOF) F/T sensor. Experiments are conducted to verify the effectiveness and efficiency of the proposed assembly scheme. The performances of the dual-arm robot are consistent with those of human beings in the peg-in-hole assembly process. The peg and hole with 0.5 mm clearance for round pieces and square pieces can be assembled successfully.

1 September 2020 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
YHYanjiang Huang
Yanjiang Huang
KCKaibin Chen
Kaibin Chen
XZXianmin Zhang
Xianmin Zhang
KWKai Wang
Kai Wang
JOJun Ota
Jun Ota

24 February 2018 in Sensors
Verified
Journal Article
Open access
PDF file
KWKai Wang
Kai Wang
XZXianmin Zhang
Xianmin Zhang
JOJun Ota
Jun Ota
YHYanjiang Huang
Yanjiang Huang
This paper proposes a nonlinear correlation-based wavelet scale selection technology to select the effective wavelet scales for the estimation of handgrip force from surface electromyograms (SEMG). The SEMG signal corresponding to gripping force was collected from extensor and flexor forearm muscles during the force-varying analysis task. We performed a computational sensitivity analysis on the initial nonlinear SEMG-handgrip force model. To explore the nonlinear correlation between ten wavelet scales and handgrip force, a large-scale iteration based on the Monte Carlo simulation was conducted. To choose a suitable combination of scales, we proposed a rule to combine wavelet scales based on the sensitivity of each scale and selected the appropriate combination of wavelet scales based on sequence combination analysis (SCA). The results of SCA indicated that the scale combination VI is suitable for estimating force from the extensors and the combination V is suitable for the flexors. The proposed method was compared to two former methods through prolonged static and force-varying contraction tasks. The experiment results showed that the root mean square errors derived by the proposed method for both static and force-varying contraction tasks were less than 20%. The accuracy and robustness of the handgrip force derived by the proposed method is better than that obtained by the former methods.

27 November 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KWKai Wang
Kai Wang
XZXianmin Zhang
Xianmin Zhang
JOJun Ota
Jun Ota
YHYanjiang Huang
Yanjiang Huang
In this paper, a cross model selection (CMS) technology is proposed to accurately estimate the handgrip force from the surface electromyography (SEMG). The proposed model is based on a cross model and sequence combination analysis (SCA). The cross model is built by sampling data collected from constant force training tasks (isometric muscle contraction) and force-varying training tasks (gradual dynamic muscle contraction). Isometric contraction data is used to build SEMG-force relationships with regularization. Then, the cross validation (CV) technique is employed by using gradual dynamic contraction data to obtain the optimal regularization parameter. According to the zero-approaching characteristics of the parameter selected by CV, this study proposes a SCA method to select a suitable combination of coefficient terms for the CMS model. Through the constant force and force-varying validation tasks, the experimental results showed that the handgrip force estimated from SEMG using the proposed model has higher accuracy than the former models.