The use of guided wave-based Ultrasonic Testing (UT) for monitoring Polyethylene (PE) pipes is mostly restricted to detecting defects in welded zones, despite its diversified success in monitoring metallic pipes. PE’s viscoelastic behavior and semi-crystalline structure make it prone to crack formation under extreme loads and environmental factors, which is a leading cause of pipeline failure. This state-of-the-art study aims to demonstrate the potential of UT for detecting cracks in non-welded regions of natural gas PE pipes. Laboratory experiments were conducted using a UT system consisting of low-cost piezoceramic transducers assembled in a pitch-catch configuration. The amplitude of the transmitted wave was analyzed to study wave interaction with cracks of different geometries. The frequency of the inspecting signal was optimized through wave dispersion and attenuation analysis, guiding the selection of third- and fourth- order longitudinal modes for the study. The findings revealed that cracks with lengths equal to or greater than the wavelength of the interacting mode were more easily detectable, while smaller crack lengths required greater crack depths for detection. However, there were potential limitations in the proposed technique related to crack orientation. These insights were validated using a finite element-based numerical model, confirming the potential of UT for detecting cracks in PE pipes.
Bolted steel plate joints encounter challenges posed by joint corrosion, which impact the quality of interfacial contact among the bolted components. Unfortunately, no correlation between corrosion-induced joint damage and preload, nor an existing numerical model capable of capturing such effects, has been identified. This study aims to utilize guided wave ultrasonic investigation to examine the deterioration of interfacial contact caused by corrosion in bolted joints. Additionally, a contact modification-based numerical approach is presented to capture the effects of changing interfacial stress during joint corrosion. Guided wave mode selection was conducted with some preliminary experiments supplemented with the theory of wave mode dispersion, hence leading to the selection of S0 and A0 mode existing at 300 kHz. The joint was then corroded in a controlled manner using an electrochemical process while simultaneous ultrasonic measurements were taken. The experimental observations highlighted the progressive dispersion in the transmitted A0 mode across the bolted joint, potentially due to changing interfacial stress boundaries between the plates. A damage parameter, termed the dispersion index, was developed based on the energy ratio of different signal sections. A linear change in the dispersion index was observed with the increase in corrosion-induced mass loss. The insight was further established through a numerical investigation by studying the effect of changing bolt preload and the corresponding interfacial stress distribution. The findings revealed that monitoring the changes in the stress distribution at the bolted interface can provide insight into interfacial corrosion. Eventually, destructive tension test results confirmed the effect of joint corrosion on the load-bearing capacity of the joint. The change in failure mode of the pristine and corroded specimen is observed. The reported approach establishes the potential of ultrasonic inspection to investigate the interfacial health of a bolted joint in corroding conditions.