Alexander Robert Craik

Mr. Alexander Robert Craik


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2019 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
ACAlexander Robert Craik
Alexander Robert Craik
YHYongtian He
Yongtian He
Jose L Contreras-VidalJose L Contreras-Vidal
Jose L Contreras-Vidal
Electroencephalography (EEG) analysis has been an important tool in neuroscience with applications in neuroscience, neural engineering (e.g. Brain-computer interfaces, BCI's), and even commercial applications. Many of the analytical tools used in EEG studies have used machine learning to uncover relevant information for neural classification and neuroimaging. Recently, the availability of large EEG data sets and advances in machine learning have both led to the deployment of deep learning architectures, especially in the analysis of EEG signals and in understanding the information it may contain for brain functionality. The robust automatic classification of these signals is an important step towards making the use of EEG more practical in many applications and less reliant on trained professionals. Towards this goal, a systematic review of the literature on deep learning applications to EEG classification was performed to address the following critical questions: (1) Which EEG classification tasks have been explored with deep learning? (2) What input formulations have been used for training the deep networks? (3) Are there specific deep learning network structures suitable for specific types of tasks? A systematic literature review of EEG classification using deep learning was performed on Web of Science and PubMed databases, resulting in 90 identified studies. Those studies were analyzed based on type of task, EEG preprocessing methods, input type, and deep learning architecture. For EEG classification tasks, convolutional neural networks, recurrent neural networks, deep belief networks outperform stacked auto-encoders and multi-layer perceptron neural networks in classification accuracy. The tasks that used deep learning fell into five general groups: emotion recognition, motor imagery, mental workload, seizure detection, event related potential detection, and sleep scoring. For each type of task, we describe the specific input formulation, major characteristics, and end classifier recommendations found through this review. This review summarizes the current practices and performance outcomes in the use of deep learning for EEG classification. Practical suggestions on the selection of many hyperparameters are provided in the hope that they will promote or guide the deployment of deep learning to EEG datasets in future research.

26 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ACAlexander Robert Craik
Alexander Robert Craik
JEJuan Jose Gonzalez Espana
Juan Jose Gonzalez Espana
AAAyman Alamir
Ayman Alamir
DEDavid Edquilang
David Edquilang
SWSarah Wong
Sarah Wong
Jose L Contreras-VidalJose L Contreras-Vidal
Jose L Contreras-Vidal
Objective: We designed and validated a wireless, low-cost, easy-to-use, mobile, dry-electrode headset for scalp electroencephalography (EEG) recordings for closed-loop brain–computer (BCI) interface and internet-of-things (IoT) applications. Approach: The EEG-based BCI headset was designed from commercial off-the-shelf (COTS) components using a multi-pronged approach that balanced interoperability, cost, portability, usability, form factor, reliability, and closed-loop operation. Main Results: The adjustable headset was designed to accommodate 90% of the population. A patent-pending self-positioning dry electrode bracket allowed for vertical self-positioning while parting the user’s hair to ensure contact of the electrode with the scalp. In the current prototype, five EEG electrodes were incorporated in the electrode bracket spanning the sensorimotor cortices bilaterally, and three skin sensors were included to measure eye movement and blinks. An inertial measurement unit (IMU) provides monitoring of head movements. The EEG amplifier operates with 24-bit resolution up to 500 Hz sampling frequency and can communicate with other devices using 802.11 b/g/n WiFi. It has high signal–to–noise ratio (SNR) and common–mode rejection ratio (CMRR) (121 dB and 110 dB, respectively) and low input noise. In closed-loop BCI mode, the system can operate at 40 Hz, including real-time adaptive noise cancellation and 512 MB of processor memory. It supports LabVIEW as a backend coding language and JavaScript (JS), Cascading Style Sheets (CSS), and HyperText Markup Language (HTML) as front-end coding languages and includes training and optimization of support vector machine (SVM) neural classifiers. Extensive bench testing supports the technical specifications and human-subject pilot testing of a closed-loop BCI application to support upper-limb rehabilitation and provides proof-of-concept validation for the device’s use at both the clinic and at home. Significance: The usability, interoperability, portability, reliability, and programmability of the proposed wireless closed-loop BCI system provides a low-cost solution for BCI and neurorehabilitation research and IoT applications.

15 May 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
ACAlexander Robert Craik
Alexander Robert Craik
JEJuan Jose Gonzalez Espana
Juan Jose Gonzalez Espana
AAAyman Alamir
Ayman Alamir
DEDavid Edquilang
David Edquilang
SWSarah Wong
Sarah Wong
Jose L Contreras-VidalJose L Contreras-Vidal
Jose L Contreras-Vidal
Objective: Design and validate a wireless, low-cost, easy-to-use, mobile, dry-electrode headset for scalp electroencephalography (EEG) recordings for closed-loop brain-computer (BCI) interface and internet-of-things (IoT) applications. Approach: The EEG-based BCI headset was designed from commercial off-the-shelf (COTS) components using a multi-pronged approach that balanced interoperability, cost, portability, usability, form factor, reliability, and closed-loop operation. Main Results: The adjustable headset was designed to accommodate 90\% of the population. A patent-pending self-positioning dry electrode bracket allowed for vertical self-positioning while parting the user's hair to ensure contact of the electrode with the scalp. In the current prototype, five EEG electrodes were incorporated in the electrode bracket spanning the sensorimotor cortices bilaterally, and three skin sensors were included to measure eye movement and blinks. An accelerometer provides monitoring of head movements. The EEG amplifier operates with 24 bits resolution up to 500 Hz sampling frequency, and can communicate with other devices using 802.11 {b/g/n/WiFi}. It has high SNR and CMRR (121 dB and 110 dB, respectively), and low input noise. In closed-loop BCI mode, the system can operate at 40 Hz, including real-time adaptive noise cancellation and 512 MB of processor memory. It supports LabVIEW as backend coding language and JS, CSS, HTML as front-end coding languages, and includes training and optimization of Support Vector Machine (SVM) neural classifiers. Extensive bench testing supports the technical specifications and human subject pilot testing of a closed-loop BCI application to support upper-limb rehabilitation provides proof-of-concept validation for device use at both the clinic and at home. Significance: The low-cost, accessibility, usability, interoperability, and programmability of the proposed closed-loop BCI system provides a low-cost solution for BCI and neurorehabilitation research and IoT applications.

21 January 2022
Verified
Book Chapter
Closed access
PDF file
SNSho Nakagome
Sho Nakagome
ACAlexander Robert Craik
Alexander Robert Craik
ARAkshay Sujatha Ravindran
Akshay Sujatha Ravindran
YHYongtian He
Yongtian He
JCJesus Gabriel Cruz-Garza
Jesus Gabriel Cruz-Garza
Jose L Contreras-VidalJose L Contreras-Vidal
Jose L Contreras-Vidal

14 March 2025 in Journal of Neural Engineering
Verified
Journal Article
Open access
ACAlexander Robert Craik
Alexander Robert Craik
HDHeather Dial
Heather Dial
Jose L Contreras-VidalJose L Contreras-Vidal
Jose L Contreras-Vidal
Objective. Neurological disorders affecting speech production adversely impact quality of life for over 7 million individuals in the US. Traditional speech interfaces like eye-tracking devices and P300 spellers are slow and unnatural for these patients. An alternative solution, speech brain-computer interfaces (BCIs), directly decodes speech characteristics, offering a more natural communication mechanism. This research explores the feasibility of decoding speech features using non-invasive EEG. Approach. Nine neurologically intact participants were equipped with a 63-channel EEG system with additional sensors to eliminate eye artifacts. Participants read aloud sentences selected for phonetic similarity to the English language. Deep learning models, including Convolutional Neural Networks and Recurrent Neural Networks with and without attention modules, were optimized with a focus on minimizing trainable parameters and utilizing small input window sizes for real-time application. These models were employed for discrete and continuous speech decoding tasks. Main results. Statistically significant participant-independent decoding performance was achieved for discrete classes and continuous characteristics of the produced audio signal. A frequency sub-band analysis highlighted the significance of certain frequency bands (delta, theta, gamma) for decoding performance, and a perturbation analysis was used to identify crucial channels. Assessed channel selection methods did not significantly improve performance, suggesting a distributed representation of speech information encoded in the EEG signals. Leave-One-Out training demonstrated the feasibility of utilizing common speech neural correlates, reducing data collection requirements from individual participants. Significance. These findings contribute significantly to the development of EEG-enabled speech synthesis by demonstrating the feasibility of decoding both discrete and continuous speech features from EEG signals, even in the presence of EMG artifacts. By addressing the challenges of EMG interference and optimizing deep learning models for speech decoding, this study lays a strong foundation for EEG-based speech BCIs.

23 May 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
ACAlexander Robert Craik
Alexander Robert Craik
HDHeather Dial
Heather Dial
Jose L Contreras-VidalJose L Contreras-Vidal
Jose L Contreras-Vidal
Neurological disorders affecting speech production adversely impact quality of life for over 7 million individuals in the US. Traditional speech interfaces like eye-tracking devices and P300 spellers are slow and unnatural for these patients. An alternative solution, speech Brain-Computer Interfaces (BCIs), directly decodes speech characteristics, offering a more natural communication mechanism. This research explores the feasibility of decoding speech features using non-invasive EEG. Nine neurologically intact participants were equipped with a 63-channel EEG system with additional sensors to eliminate eye artifacts. Participants read aloud sentences displayed on a screen selected for phonetic similarity to the English language. Deep learning models, including Convolutional Neural Networks and Recurrent Neural Networks with/without attention modules, were optimized with a focus on minimizing trainable parameters and utilizing small input window sizes. These models were employed for discrete and continuous speech decoding tasks, achieving above-chance participant-independent decoding performance for discrete classes and continuous characteristics of the produced audio signal. A frequency sub-band analysis highlighted the significance of certain frequency bands (delta, theta, and gamma) for decoding performance, and a perturbation analysis identified crucial channels. Assessed channel selection methods did not significantly improve performance, but they still outperformed chance levels, suggesting a distributed representation of speech information encoded in the EEG signals. Leave-One-Out training demonstrated the feasibility of utilizing common speech neural correlates, reducing data collection requirements from individual participants.