Jean Christophe Veilleux

Mr. Jean Christophe Veilleux

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in Journal of Fluids and Structures
Verified
Journal Article
Closed access
JVJean Christophe Veilleux
Jean Christophe Veilleux
GDGuy Dumas
Guy Dumas

30 June 2020 in Current Medical Research and Opinion
Verified
Journal Article
Open access
ZDZhongwang Dou
Zhongwang Dou
JEJavad Eshraghi
Javad Eshraghi
TGTianqi Guo
Tianqi Guo
JVJean Christophe Veilleux
Jean Christophe Veilleux
KDKevin H. Duffy
Kevin H. Duffy
PVPavlos P. Vlachos
Pavlos P. Vlachos
Objective: Autoinjectors are a convenient and efficient way to self-administer subcutaneous injections of biopharmaceuticals. Differences in device mechanical design can affect the autoinjector functionality and performance. This study investigates the performance differences of two single-spring-actuated autoinjectors. Methods: We compare the performance between Emgality (120 mg/mL) and Aimovig (140 mg/mL) autoinjector devices from an engineering point of view at two test conditions: room (25 C °) and storage (5 C °) temperatures. We employ a novel experimental procedure to simultaneously acquire the force and acoustic signals during operation, and high-speed imaging during the needle insertion and drug injection. Results: We perform 18 quantitative comparisons between Emgality and Aimovig, and we observe that 14 of these have statistically significant differences. For both test conditions, Emgality requires an 8 N activation force while Aimovig requires 14 N activation force, and the needle of Emgality has an insertion depth of 5 mm while Aimovig has an insertion depth of 7 mm. The injection speeds are significantly affected by temperature. Emgality has an injection speed of 0.40 mL/s and 0.28 mL/s at room and storage temperature condition, respectively; while Aimovig has an injection speed of 0.24 mL/s and 0.16 mL/s at those conditions. Lastly, confirmation “click” sound of Emgality occurs 0.75–1.53 s after dose completion, while in Aimovig, the confirmation “click” sound occurs 0.26-0.46 s before dose completion. Conclusions: This study revealed performance differences between Emgality and Aimovig autoinjector devices, despite the fact that the delivery principle of these single-spring-actuated autoinjectors are the same. These differences may result in different risk of intramuscular injection and premature device removal, both of which need to be further verified in clinical trials.

6 August 2018 in Drug Delivery and Translational Research
Verified
Journal Article
Closed access
PDF file
JVJean Christophe Veilleux
Jean Christophe Veilleux
JSJoseph E. Shepherd
Joseph E. Shepherd

1 August 2017 in Aerospace
Verified
Journal Article
Open access
PDF file
MBMatthieu Boudreau
Matthieu Boudreau
GDGuy Dumas
Guy Dumas
JVJean Christophe Veilleux
Jean Christophe Veilleux
A detailed numerical investigation of the flow behind a square cylinder at a Reynolds number of 21,400 is conducted to assess the ability of the delayed detached-eddy simulation (DDES) modeling approach to accurately predict the velocity recovery in the wake of a bluff body. Three-dimensional unsteady Reynolds-averaged Navier–Stokes (URANS) and DDES simulations making use of the Spalart–Allmaras turbulence model are carried out using the open-source computational fluid dynamics (CFD) toolbox OpenFOAM-2.1.x, and are compared with available experimental velocity measurements. It is found that the DDES simulation tends to overestimate the averaged streamwise velocity component, especially in the near wake, but a better agreement with the experimental data is observed further downstream of the body. The velocity fluctuations also match reasonably well with the experimental data. Moreover, it is found that the spanwise domain length has a significant impact on the flow, especially regarding the fluctuations of the drag coefficient. Nonetheless, for both the averaged and fluctuating velocity components, the DDES approach is shown to be superior to the URANS approach. Therefore, for engineering purposes, it is found that the DDES approach is a suitable choice to simulate and characterize the velocity recovery in a wake.

22 October 2022 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
XZXiaoxu Zhong
Xiaoxu Zhong
HMHarsa Mitra
Harsa Mitra
JVJean Christophe Veilleux
Jean Christophe Veilleux
ESEmma Simmons
Emma Simmons
GSGalen Huaiqiu Shi
Galen Huaiqiu Shi
AAArezoo Ardekani
Arezoo Ardekani

19 July 2022 in Pharmaceutical Research
Verified
Journal Article
Closed access
PDF file
JEJavad Eshraghi
Javad Eshraghi
JVJean Christophe Veilleux
Jean Christophe Veilleux
GSGalen Shi
Galen Shi
DCDavid Collins
David Collins
AAArezoo Ardekani
Arezoo Ardekani
PVPavlos P. Vlachos
Pavlos P. Vlachos