Purpose: In cochlear implantation, thorough preoperative planning together with measurement of the cochlear duct length (CDL) assists in choosing the correct electrode length. For measuring the CDL, different techniques have been introduced in the past century along with the then available technology. A tablet-based software offers an easy and intuitive way to visualize and analyze the anatomy of the temporal bone, its proportions and measure the CDL. Therefore, we investigated the calculation technique of the CDL via a tablet-based software on our own cohort retrospectively.Methods: One hundred and eight preoperative computed tomography scans of the temporal bone (slice thickness < 0.7 mm) of already implanted FLEX28™ and FLEXSOFT™ patients were found eligible for analysis with the OTOPLAN software. Measurements were performed by two trained investigators independently. CDL, angular insertion depth (AID), and cochlear coverage were calculated and compared between groups of electrode types, sex, sides, and age.Results: Mean CDL was 36.2 ± 1.8 mm with significant differences between sex (female: 35.8 ± 0.3 mm; male: 36.5 ± 0.2 mm;p = 0.037), but none concerning side or age. Differences in mean AID (FLEX28: 525.4 ± 46.4°; FLEXSOFT: 615.4 ± 47.6°), and cochlear coverage (FLEX28: 63.9 ± 5.6%; FLEXSOFT: 75.8 ± 4.3%) were significant (p < 0.001).Conclusion: A broad range of CDL was observed with significant larger values in male, but no significant differences concerning side or age. Almost every cochlea was measured longer than 31.0 mm. Preoperative assessment aids in prevention of complications (incomplete insertion, kinking, tipfoldover), attempt of atraumatic insertion, and addressing individual necessities (hearing preservation, cochlear malformation). The preferred AID of 720° (two turns of the cochlea) was never reached, opening the discussion for the requirement of longer CI-electrodes versus a debatable audiological benefit for the patient in his/her everyday life.
Due to increasing drug resistance, artemisinin-based combination chemotherapy (ACT) has become the first-line treatment of falciparum malaria in many endemic countries. However, irreversible ototoxicity associated with artemether/lumefantrine (AL) has been reported recently and suggested to be a serious limitation in the use of ACT. The aim of the study was to compare ototoxicity, tolerability, and efficacy of ACT with that of quinine and atovaquone/proguanil in the treatment of uncomplicated falciparum malaria.
Investigate whether the cochleostomy is a possible port of entry for pneumolabyrinth and a resulting vertigo in patients provided with a cochlear implant. Retrospective case review. Ludwig-Maximilians University of Munich, Hospital Grosshadern. 62-year-old patient who underwent implantation of a HiFocus II cochlear implant with positioner from Advanced Bionics (CLARION). Eight months postoperatively, the patient reported rotatory vertigo and right-side tinnitus after he had blown his nose harder than usual during an episode of rhinitis. Preoperative and postoperative testing of both the petrosal bone with a CT scan and of balance function. Air inclusion in the labyrinth. In contrast to the preoperative high resolution computed tomography (CT) scan, air inclusion was seen in the labyrinth during the episode of vertigo. At the same time, balance function tests with Frenzel glasses revealed both spontaneous and provoked horizontal nystagmus to the right side. At follow-up 8 weeks later, the level of vertigo had significantly decreased. Twelve months later, the control CT showed the cochlear implant positioned correctly and no visible air in the labyrinth. It is known that placement of the HiFocus II with Positioner from CLARION requires a relatively large cochleostomy of 1.5 mm. Moreover, in the connective tissue seal between the electrode and the positioner, the latter reaches into the tympanic cavity, and this is possibly the weak point. Further investigation will be needed to determine whether the large cochleostomy with the HiFocus II with positioner increases the predisposition to labyrinth dysfunction.
1 April 2020 in International Journal of Pediatric Otorhinolaryngology
Despite the use of a flexible electrode, complete preservation of low frequency residual hearing can only be achieved in a minority of patients. The use of a full insertion electrode of 28 mm in patients with poor preoperative thresholds does not allow for usable additional hearing at present.