Introduction: Thanks to the great development of digital technology, viaCAD (computer-aided design) and CAM (computer-aided manufacturing) systems, digital models canbe used as an aid for orthodontic planning decision-making processes as there are numerous studies in the literature that support the validity ofthe digital model measurements of anterior teeth and the total coefficient of Bolton analysis. The aim of the present study isto compare the average length value of the current upper and lower arches with that of a hypothetical nickel–titanium wire and to confirm the reliability and accuracy of digitally taken measurements of the anterior and total Bolton coefficients.In this retrospective study, dental casts of 138 Caucasian adolescent patients were scanned with an extraoral scanner, and Ortho3Shape software was adopted for the following dental cast measurements: actual and ideal lengths of the lower arches and anterior and total Bolton coefficients.In the present study, we found that the mean value of the anterior coefficients of the Bolton index was compatible with those of previous studies, confirming the reliability of digital measurements.Therefore, digital CAD/CAM models may be a viable alternative to plaster models, as they can facilitate model preservation and recovery. For future studies, it would be better to use intraoral scanners (IOSs) to ensure greater accuracy, since they only require one step and allow obtaining better results for the patients.
Introduction: Due to the great development of digital technology, through CAD (Computer - Aided Design) and CAM (Computer - Aided Manufacturing) systems, digital models could be used in orthodontic treatment planning decision-making, as there are numerous studies in the literature that support the validity of measurements of digital models of anterior teeth and the total coefficient of Bolton analysis. The aim of the study was to compare the average length value of the current upper and lower arches with that of a hypothetical nickel-titanium wire and the accuracy of the Bolton index measurement. In the present study, 138 dental casts were analyzed using Ortho3Shape software. Using the Ortho3Shape software, it was possible to measure the real and ideal lower arch lengths and, with regard to Bolton analysis, the values of the anterior and total Bolton coefficients. By comparing the values obtained with those of the study by A. Anand Kumar et al. using CBCT and plaster casts, the reliability of the measurements obtained with such CAD/CAM orthodontic software was evaluated. Considering the validity of digital measurements demonstrated by the studies and systematic reviews in the literature, it can be stated that CAD/CAM digital models can be a viable alternative to plaster models in the coming years, as they can facilitate model preservation and retrieval. For future studies and research, it would be preferable to use intra-oral scanners (IOS) in order to ensure greater accuracy, requiring only one step and ensuring a better outcome for the patient.