Sonette du Preez

Dr. Sonette du Preez


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Safety and Health at Work
Verified
Journal Article
Open access
ASAleksandr B. Stefaniak
Aleksandr B. Stefaniak
AJA.R. Johnson
A.R. Johnson
SPSonette du Preez
Sonette du Preez
DHD.R. Hammond
D.R. Hammond
JWJ.R. Wells
J.R. Wells
JPJeanetta Du Plessis
Jeanetta Du Plessis
Emerging reports suggest the potential for adverse health effects from exposure to emissions from some additive manufacturing (AM) processes. There is a paucity of real-world data on emissions from AM machines in industrial workplaces and personal exposures among AM operators. Airborne particle and organic chemical emissions and personal exposures were characterized using real-time and time-integrated sampling techniques in four manufacturing facilities using industrial-scale material extrusion and material jetting AM processes. Using a condensation nuclei counter, number-based particle emission rates (ERs) (number/min) from material extrusion AM machines ranged from 4.1 × 1010 (Ultem filament) to 2.2 × 1011 [acrylonitrile butadiene styrene and polycarbonate filaments). For these same machines, total volatile organic compound ERs (μg/min) ranged from 1.9 × 104 (acrylonitrile butadiene styrene and polycarbonate) to 9.4 × 104 (Ultem). For the material jetting machines, the number-based particle ER was higher when the lid was open (2.3 × 1010 number/min) than when the lid was closed (1.5-5.5 × 109 number/min); total volatile organic compound ERs were similar regardless of the lid position. Low levels of acetone, benzene, toluene, and m,p-xylene were common to both AM processes. Carbonyl compounds were detected; however, none were specifically attributed to the AM processes. Personal exposures to metals (aluminum and iron) and eight volatile organic compounds were all below National Institute for Occupational Safety and Health (NIOSH)-recommended exposure levels. Industrial-scale AM machines using thermoplastics and resins released particles and organic vapors into workplace air. More research is needed to understand factors influencing real-world industrial-scale AM process emissions and exposures.

1 December 2018 in South African Journal of Industrial Engineering
Verified
Journal Article
Open access
PDF file
SPSonette du Preez
Sonette du Preez
Deon de BeerDeon de Beer
Deon de Beer
JPJohan Lodewykus du Plessis
Johan Lodewykus du Plessis
TITANIUM POWDERS USED IN POWDER BED FUSION: THEIR RELEVANCE TO RESPIRATORY HEALTH

Marelize Van ReeMarelize Van Ree
Marelize Van Ree
SPSonette du Preez
Sonette du Preez
JPJeanetta Du Plessis
Jeanetta Du Plessis
Additive manufacturing (AM) has been linked to potential exposure-related health risks, however, there is a paucity of sufficient research. This study aimed to supply information regarding emissions and exposure during directed energy deposition (DED) AM using inconel 718, with the main constituents being nickel, chromium, and cobalt. By using standardized occupational hygiene methods, the measurement strategy consisted of a combined approach, including powder characterization, particle emission monitoring, and personal exposure monitoring of AM operators. Powder characterization of virgin and used powder indicated no significant difference in particle size, shape, or elemental composition. Particle number emissions ranged between 102 and 105 p/cm3 for submicron particles ( 0.05). The particle emission rate for submicron particles peaked at 2.8 × 109 p/min. Metals of concern to human health were detected during the AM process but were considerably lower than the relevant exposure limits. This study confirms particle emissions, predominantly in the submicron range, above the background concentration during DED AM and, although insignificant in terms of potential health effects, AM operators are exposed to detectable concentrations of the metal constituents of inconel.

26 June 2022 in Journal of Toxicology and Environmental Health, Part B
Verified
Journal Article
Closed access
JPJeanetta Du Plessis
Jeanetta Du Plessis
SPSonette du Preez
Sonette du Preez
ASAleksandr B. Stefaniak
Aleksandr B. Stefaniak
Additive manufacturing (AM) refers to several types of processes that join materials to build objects, often layer-by-layer, from a computer-aided design file. Many AM processes release potentially hazardous particles and gases during printing and associated tasks. There is limited understanding of the efficacy of controls including elimination, substitution, administrative, and personal protective technologies to reduce or remove emissions, which is an impediment to implementation of risk mitigation strategies. The Medline, Embase, Environmental Science Collection, CINAHL, Scopus, and Web of Science databases and other resources were used to identify 42 articles that met the inclusion criteria for this review. Key findings were as follows: 1) engineering controls for material extrusion-type fused filament fabrication (FFF) 3-D printers and material jetting printers that included local exhaust ventilation generally exhibited higher efficacy to decrease particle and gas levels compared with isolation alone, and 2) engineering controls for particle emissions from FFF 3-D printers displayed higher efficacy for ultrafine particles compared with fine particles and in test chambers compared with real-world settings. Critical knowledge gaps identified included a need for data: 1) on efficacy of controls for all AM process types, 2) better understanding approaches to control particles over a range of sizes and gas-phase emissions, 3) obtained using a standardized collection approach to facilitate inter-comparison of study results, 4) approaches that go beyond the inhalation exposure pathway to include controls to minimize dermal exposures, and 5) to evaluate not just the engineering tier, but also the prevention-through-design and other tiers of the hierarchy of controls.


23 May 2025 in Annals of Work Exposures and Health
Verified
Journal Article
Closed access
LPLynicka Paulse
Lynicka Paulse
SPSonette du Preez
Sonette du Preez
AFAnja Franken
Anja Franken
JPJeanetta Du Plessis
Jeanetta Du Plessis
Background: Amidst the rapidly emerging additive manufacturing (AM) industry, not enough attention has been given to dermal exposure, with only one previous study that assessed dermal exposure to metals. Our study aimed to characterise a cobalt (Co)-chrome (Cr) alloy feedstock powder (CO-538) in terms of particle size, shape, and elemental composition, and assess dermal exposure and workplace surface contamination during powder bed fusion AM. Methods: Particle size distribution (PSD) and shape of the virgin and used feedstock powder were determined using static image and scanning electron microscopy analyses. The elemental composition of powders was established using inductively coupled plasma-optical emission spectrometry. A removal wipe sampling method using Ghostwipes was performed on AM operators’ skin at various locations (index finger, palm, wrist, back of the hand, and neck), before and after each AM processing phase. Workplace surfaces (both AM and non-AM areas) were also sampled before and after each shift using a removal wipe method to measure surface contamination. Results: PSD analysis revealed a significant difference (P ≤ 0.05) in median size, with used powder exhibiting smaller particles than virgin, where 10% of particles were smaller than the given diameter. Additionally, significant differences (P ≤ 0.05) were noted in the mean circularity and convexity between virgin and used powders, indicating that used powder particles were more irregular and rougher compared to virgin. The CO-538 feedstock powder contained Co, Cr, molybdenum (Mo), aluminium (Al), iron (Fe), and Ni. These metals were also detected on the skin of AM operators and on surfaces within the AM and non-AM areas of the facility. Dermal exposure occurred on all of the anatomical areas, with the highest total metal concentration detected on the index finger during the post-processing phase of AM. The highest full-shift geometric mean GM concentration of each metal was detected on the finger and followed a trend of Co > Cr > Fe > Al > Mo > Ni. Surface contamination occurred on all AM and non-AM sampling areas after a full shift. Conclusions: Dermal exposure to all CO-538 alloy metal constituents occurred on all sampled anatomical areas during all three processing phases. Measurable concentrations of metals that were detected on all sampled surfaces indicate that cross-contamination between AM and non-AM areas occurs and that these surfaces may act as a secondary source of exposure. There is thus a need for control measures to be implemented in AM facilities to eliminate or reduce surface metal contamination and dermal exposure.