Pressure in arteries is difficult to measure non-invasively. Although computational fluid dynamics (CFD) provides high-precision numerical solutions according to the basic physical equations of fluid mechanics, it relies on precise boundary conditions and complex preprocessing, which limits its real-time application. Machine learning algorithms have wide applications in hemodynamic research due to their powerful learning ability and fast calculation speed. Therefore, we proposed a novel method for pressure estimation based on physics-informed neural network (PINN). An ideal aortic arch model was established according to the geometric parameters from human aorta, and we performed CFD simulation with two-way fluid-solid coupling. The simulation results, including the space-time coordinates, the velocity and pressure field, were obtained as the dataset for the training and validation of PINN. Nondimensional Navier-Stokes equations and continuity equation were employed for the loss function of PINN, to calculate the velocity and relative pressure field. Post-processing was proposed to fit the absolute pressure of the aorta according to the linear relationship between relative pressure, elastic modulus and displacement of the vessel wall. Additionally, we explored the sensitivity of the PINN to the vascular elasticity, blood viscosity and blood velocity. The velocity and pressure field predicted by PINN yielded good consistency with the simulated values. In the interested region of the aorta, the relative errors of maximum and average absolute pressure were 7.33% and 5.71%, respectively. The relative pressure field was found most sensitive to blood velocity, followed by blood viscosity and vascular elasticity. This study has proposed a method for intra-vascular pressure estimation, which has potential significance in the diagnosis of cardiovascular diseases.
Pulmonary embolism (PE) and other pulmonary vascular diseases, have been found associated with the changes in arterial morphology. To detect arterial changes, we propose a novel, fully automatic method that can extract pulmonary arterial tree in computed tomographic pulmonary angiography (CTPA) images. The approach is based on the fuzzy connectedness framework, combined with 3D vessel enhancement and Harris Corner detection to achieve accurate segmentation. The effectiveness and robustness of the method is validated in clinical datasets consisting of 10 CT angiography scans (6 without PE and 4 with PE). The performance of our method is compared with manual classification and machine learning method based on random forest. Our method achieves a mean accuracy of 92% when compared to manual reference, which is higher than the 89% accuracy achieved by machine learning. This performance of the segmentation for pulmonary arteries may provide a basis for the CAD application of PE.
8 February 2022 in Medicine in Novel Technology and Devices
The effects of gender and other contributory factors on pulse waveform are still under arguments. In view of different results caused by few considerations of possible influential factors and general agreement of gender relating to pulse waveform, this study aims to address the confounding factors interfering with the association between gender and pulse waveform characteristics. A novel method was proposed to noninvasively detect pressure pulse wave and assess the morphology of pulse wave. Forty healthy young subjects were included in the present research. Height, weight, systolic blood pressure (SBP), and diastolic blood pressure (DBP) were measured manually and body mass index (BMI), pulse blood pressure (PP) and heart rate (HR) were calculated automatically. Student’s t test was used to analyze the gender difference and analysis of variance (ANOVA) to examine the effects of intrinsic factors. Univariate regression analysis was performed to assess the main factors on the waveform characteristics. Waveform features were found significantly different between genders. However this study indicates that the main factors for time-related and amplitude-related parameters are HR and SBP respectively. In conclusion, the impact of HR and SBP on pulse waveform features should not be underestimated, especially when analyzing the gender difference.
28 November 2018 in Journal of Mechanics in Medicine and Biology