Giada Frappa

Dr. Giada Frappa

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2024 in Engineering Structures
Verified
Journal Article
Open access
IPIngrid Rocio Irreño Palomo
Ingrid Rocio Irreño Palomo
GFGiada Frappa
Giada Frappa
LALuiz Carlos de Almeida
Luiz Carlos de Almeida
LTLeandro Mouta Trautwein
Leandro Mouta Trautwein
MPMargherita Pauletta
Margherita Pauletta

4 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LMLucas Mazzon
Lucas Mazzon
GFGiada Frappa
Giada Frappa
MPMargherita Pauletta
Margherita Pauletta
A case study where a tuned mass damper (TMD) was installed at the top of a five-story reinforced concrete (RC) building is presented. The aim of the study was to investigate the effectiveness of the TMD in changing the structural behavior of medium-rise existing buildings from dissipative to non-dissipative in order to eliminate reparation or demolition costs resulting from damages caused by strong earthquakes. The TMD mass is made by a RC slab lying on flat surface sliders. Horizontal stiffness and damping of the TMD are both provided by lead rubber isolators in the first proposed solution and by low-damping rubber isolators and viscous linear dampers, respectively, in the second. The improvement in the building’s structural behavior attained with the installation of the TMD was assessed by considering the flexural demand over capacity ratios of structural elements and the energy dissipated by the TMD. These results are compared with those of the same building retrofitted with a base isolation system. In both of the proposed solutions, TMD remarkably changed the modal behavior of the considered building, improved the flexural verifications, and dissipated most of the input seismic energy. It is therefore demonstrated that a TMD is a valid solution for the retrofit of medium-rise existing buildings.

7 November 2020 in Buildings
Verified
Journal Article
Open access
PDF file
MMMarco Miani
Marco Miani
CMCaterina Di Marco
Caterina Di Marco
GFGiada Frappa
Giada Frappa
MPMargherita Pauletta
Margherita Pauletta
Conservation of heritage buildings has become a very important issue in many countries, as it is in Italy, where a great number of existing buildings of historical–artistic importance are seismically vulnerable. To improve existing building behavior, researchers focus on the design of retrofit interventions. This paper presents the application of energy dissipation devices in the retrofit of two existing Reinforced Concrete (RC) buildings, both irregular in plan and along their heights, designed for gravitational loads only. These buildings are representative of Italian public housing built in the 1960s and early 1970s. Technical information and mechanical properties of materials are presented, and non-linear analyses are carried out to evaluate the buildings’ behavior under earthquake loads. Many of their structural members do not satisfy the verifications required by the Italian Building Code. Retrofit interventions with buckling-restrained axial dampers in one building and viscous fluid dampers in the other are proposed. The verifications of the retrofitted buildings and the amount of the energy absorbed by the devices with respect to that absorbed by the unretrofitted buildings show the effectiveness of the proposed interventions. Moreover, it is demonstrated that adequate dispositions of the dissipative devices in plan and along the height increase the torsional stiffness of the buildings, improving their structural response under seismic action.

13 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MPMargherita Pauletta
Margherita Pauletta
FPFederico Pinzano
Federico Pinzano
GFGiada Frappa
Giada Frappa
GRGaetano Russo
Gaetano Russo
Steel reinforced elastomeric isolators are currently the most used bearings for seismic isolation purposes. The steel reinforcements are cut to the desired shape, sandblasted, cleaned with acid, and coated with bonding compound during the manufacturing process. Then the elastomer and steel layers are stacked in a mold and subjected to vulcanization so that they are glued together and constitute a single body. Good adhesion between the layers is very important for the correct functioning of the device. Adhesion conditions become critical when the isolators are subjected to tensile stresses, which arise under direct tensile actions or large shear strains. To analyze the influence of changes in the manufacturing process on the isolator adhesive behavior, the authors performed tensile tests on square-shaped small-scale specimens rather than expensive shear tests on full-scale isolators. Hence, the adhesion behavior between elastomer and steel layers was investigated through the tensile tests discussed herein. Among the influencing parameters that were considered, it was found that an increase in vulcanization time does not improve the adhesion, but it may actually worsen the capacity of the isolator in terms of strength. Moreover, it was found that using elastomer without an oily component improves the adhesion between the layers and increases the isolator’s dissipative capacity.

31 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GFGiada Frappa
Giada Frappa
IPIgino Pitacco
Igino Pitacco
SBSimone Baldassi
Simone Baldassi
MPMargherita Pauletta
Margherita Pauletta
In the modelling of reinforced concrete (RC) buildings, the rigid diaphragm hypothesis to represent the in-plane behavior of floors was and still is very commonly adopted because of its simplicity and computational cheapness. However, since excessive floor in-plane deformability can cause a very different redistribution of lateral forces on vertical resisting elements, it may be necessary to consider floor deformability. This paper investigates the classical yet intriguing question of modeling orthotropic RC floor systems endowed with lightening elements by means of a uniform orthotropic slab in order to describe accurately the building response under seismic loads. The simplified method, commonly adopted by engineers and based on the equivalence between the transverse stiffness of the RC elements of the real floor and those of the orthotropic slab, is presented. A case study in which this simplified method is used is also provided. Then, an advanced finite element (FE)-based method to determine the elastic properties of the equivalent homogenized orthotropic slab is proposed. The novel aspect of this method is that it takes into account the interaction of shell elements with frame elements in the 3D FE model of the building. Based on the results obtained from the application of this method to a case study, a discussion on the adequacy of the simplified method is also provided.